MinerU
Transforms complex documents like PDFs and Office docs into LLM-ready markdown/JSON for your Agentic workflows.
Read, check and what-if Ventsim mine ventilation models (.vsm files)
Skills that teach the AI this kind of work; they work alongside this one
Transforms complex documents like PDFs and Office docs into LLM-ready markdown/JSON for your Agentic workflows.
A privacy-first app that strips AI watermarks from content you own.
Agent skills for Obsidian. Teach your agent to use Obsidian CLI and open formats including Markdown, Bases, JSON Canvas.
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 0/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 12/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 12/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install Ventsim. Follow https://mcp.popnx.com/i/agenticeram-ventsim-mcp.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 26, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Ventsim for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "ventsim": { "command": "uvx", "args": [ "ventsim-mcp" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Ventsim tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"ventsim": {
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}Use Ventsim and tell me what you can do for me, then show me one thing✓ If Claude says it is using Ventsim or shows a Ventsim tool in the answer, you are connected
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect Ventsim yet
Ventsim runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect Ventsim
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Ventsim for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user ventsim -- uvx ventsim-mcp 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Ventsim tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user ventsim -- uvx ventsim-mcpYou should see Ventsim listed as connected
Use Ventsim and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using Ventsim or shows a Ventsim tool in the answer, you are connected
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Ventsim for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "ventsim": { "command": "uvx", "args": [ "ventsim-mcp" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Ventsim tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Ventsim and tell me what you can do for me, then show me one thing✓ If Cursor says it is using Ventsim or shows a Ventsim tool in the answer, you are connected
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Ventsim for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "ventsim": { "type": "stdio", "command": "uvx", "args": [ "ventsim-mcp" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Ventsim tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Ventsim and tell me what you can do for me, then show me one thing✓ If VS Code says it is using Ventsim or shows a Ventsim tool in the answer, you are connected
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user ventsim -- uvx ventsim-mcpClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"ventsim": {
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"ventsim": {
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"ventsim": {
"type": "stdio",
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
io.github.agenticeram/ventsim-mcppypi: ventsim-mcpBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 26, 2026
The registry name was verified with the GitHub account agenticeram, which owns the repo
Code last changed today
Uses MIT
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
Not checked yet
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/agenticeram-ventsim-mcp)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed today, and the latest version (0.11.0) reached the registry today.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: Puter MCP, XcodeBuildMCP, Vexa, Atlassian Rovo MCP Server, MR Office
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Puter MCP enables AI tools to interact with Puter: manage files, websites, workers, and more
XcodeBuildMCP provides tools for Xcode project management, simulator management, and app utilities.
Meeting bot and transcripts for Google Meet, Teams and Zoom. Live or after, speakers labelled.
Atlassian’s official server lets AI search and manage Jira work and Confluence pages. Connects to Atlassian’s cloud with OAuth sign-in.
Create, open and edit documents, spreadsheets and PDFs in MR Office's editor, inline in chat.
| This one Ventsim | Puter MCP | XcodeBuildMCP | Vexa | Atlassian Rovo MCP Server | MR Office | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Cloud or install on your computer |
| Needs a key | No | No | No | Yes | No | No |
| Add with + in Claude | No | No | No | No | Yes | No |
| Basic checks | 3/3 | 4/4 | 3/3 | 2/4 | 4/4 | 5/5 |
| License | MIT | AGPL-3.0 | MIT | Apache-2.0 | Apache-2.0 | AGPL-3.0 |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
An MCP server that lets AI assistants read and inspect Ventsim mine ventilation models (.vsm files).
It works on the model file itself, so Ventsim does not need to be running. It reads the geometry, fans and the results Ventsim saved in the file, and has its own experimental airflow, temperature and gas solvers for what-if questions; confirm important results in Ventsim.
Unofficial. Not affiliated with or endorsed by Howden / Chasm Consulting. "Ventsim" is
their trademark. The
.vsmformat is undocumented; it was read from files saved by
Ventsim DESIGN 6 and may change between versions.
| Tool | What it does |
|---|---|
model_summary | Title, Ventsim version, airway and fan counts, total length, depth range |
list_airways | Filter by name/notes or minimum velocity, sort by any field (airflow, length, pressure...) |
get_airway | Every column of one airway |
list_fans | Fan airways with fan model name, duty airflow, fan pressure, power |
velocity_check | Airways above a maximum (or below a minimum) air velocity |
fan_duty_check | Where each fan runs on its curve: airflow per fan, stall margin, flags fans in or near the stall region or off the curve |
fan_summary | Fans by model with total Fan Power as stored in the file (kW) |
compare_models | Diff two saved versions: added/removed airways, airflow and pressure changes |
check_flow_balance | Airflow mass balance at every junction (finds un-simulated or broken networks) |
what_if | Experimental: re-solve the network after scaling airway resistance, switching fans off or changing fan speed, report airflow changes |
size_regulator | Experimental: resistance, pressure drop and approximate opening area of a regulator that brings one airway to a target airflow |
trace_airflow | Main airflow path through an airway from intake to exhaust, with length and frictional pressure along it |
simulate_airflow | Experimental: solve the airflow from the model inputs alone (no saved results needed), with optional changes |
simulate_heat | Experimental: air temperature through the network after airflow changes or with extra heat sources (diesel, fire, coolers) |
contaminant_spread | Experimental: steady-state gas / smoke concentration downstream of release points |
render_network | Draw the network to SVG (plan or section), coloured by any field, fans marked, paths highlighted |
export_csv | Airways to CSV, any columns |
edit_airways | Experimental: write a copy with changed Notes / Group / Branch Name, fan speed or fan on/off, airway size, length or friction factor (resistance follows) |
add_airways | Experimental: write a copy with new airways (copied from an existing one, joined to the network where the ends meet) |
list_airways takes units="imperial" (cfm, fpm, ft, in. w.g., hp).
All values are in the SI units Ventsim stores internally (m, m3/s, Pa, kW).
pip install ventsim-mcp
Claude Desktop / Claude Code config:
{ "mcpServers": { "ventsim": { "command": "ventsim-mcp" } } }
Then ask, for example: *"Open C:\models\mine.vsm and list the 10 airways with the highest velocity."*
A .vsm is a gzip-compressed, CRLF-separated, tab-delimited text file. The airway table starts at a header line beginning MAIN Unique No, which names all ~288 columns; the parser uses those names, never fixed positions. Reading and writing is byte-exact when nothing is edited. A .txt export of the same file (uncompressed) is read too. The CSV/NBC/XLSX exports are headerless or derived dumps of the same tables and are not supported; use the .vsm/.txt.
what_if solves node pressures for the airways of the simulated stage, balancing mass flow (air expands as it warms) with dP = R*Q|Q| - Ps(Q) - NVP on every airway. What it reads from the file:
Stage is a bit mask and an airway that differs between stages is stored once per stage, on top of each other. The stage whose saved airflow balances is used.what_if multiplies it. Closed airways carry no air.Because these inputs come from the saved state, re-solving an unchanged model reproduces Ventsim's airflow almost exactly. That checks the network was read correctly (stages, junctions, closed airways, fans); it is not an accuracy figure for changes (total absolute flow error / total flow, python bench/fit.py ):
| Ventsim DESIGN 6 example | Airways solved | Error |
|---|---|---|
| diamondmine | 1,057 | 0.06 % |
| Tutorial2 | 184 | 0.04 % |
| InclinedHeatMine | 810 | 0.02 % |
| the other 17 examples (CoalMine 3,403 airways, Blue_sky, Fire, HVAC, ...) | < 0.01 % |
Accuracy for changes. Fire and Fire2 are the same network with two airway resistances changed. Predicting Fire2 from Fire plus those two changes (python bench/predict.py Fire.vsm Fire2.vsm) gives an airflow error of 0.03 % of total flow; it reproduces 96.7 % of the airflow change Ventsim computed. This is the only such pair among the shipped examples, so treat it as one data point.
Heat, density and fire effects are not re-evaluated after a change. Treat results as an estimate and confirm in Ventsim.
simulate_airflow does not use any saved result: resistance (Resistance Total), fan curves at their speed and count, fixed-flow airways, fixed-pressure airways (only when Ventsim's flag for it is set), closed airways, ends open to surface and dead ends (read from Ventsim's branch flags). Air is taken as incompressible and natural ventilation is ignored, unless use_saved_heat=True borrows both from the saved results. Compared with the airflow Ventsim saved (python bench/simulate.py ):
| Ventsim DESIGN 6 examples | Error, cold | With saved heat |
|---|---|---|
| CoalMine2, Heat Strategies, Tutorial1, RealMine, DemoMine | 0.0 - 0.2 % | same |
| Tutorial2, DevSolids, RealMine 2 | 0.2 - 1.2 % | same |
| CoalMine, diamondmine, without_ducting, Natural Ventilation Effects | 2 - 4 % | 1.3 - 3.5 % |
| Fire, Fire2, InclinedHeatMine (heat-driven) | 6 - 28 % | 0.6 - 2 % |
| Blue_sky | 8.5 % | 5.4 % |
| HVACDemo, A, B (building ducts with room outlets) | not supported |
The remaining differences come from what the file does not spell out: heat and natural ventilation, how Ventsim applies total-pressure fan curves, leakage on ducts.
simulate_heat carries the dry-bulb temperature along the airflow, fully mixed at junctions. Each airway keeps the sensible heat Ventsim saved for it (rock, diesel, fans, other sources); the auto-compression part of it is split off and follows the new mass flow. Extra sources (kW, negative for cooling) can be added; a stopped fan's power is taken out and a speed change scales it with speed cubed. Changes are reported against the unchanged model, and baseline_fit says how well that matches Ventsim.
Re-running an unchanged model with its saved airflow (python bench/heat.py ) is a reproduction check, not an accuracy figure for changes, because the heat comes from the same saved results. Outlet dry-bulb temperature, airways above 0.5 kg/s, mass-flow weighted mean / 95th percentile / worst single airway of |error|:
| Ventsim DESIGN 6 example | Airways | Mean | p95 | Max |
|---|---|---|---|---|
| Heat Strategies | 30 | 0.03 K | 0.05 K | 0.05 K |
| diamondmine | 761 | 0.17 K | 0.31 K | 2.9 K |
| Natural Ventilation Effects | 186 | 0.18 K | 0.47 K | 0.6 K |
| InclinedHeatMine | 731 | 0.18 K | 0.65 K | 14 K |
| Blue_sky | 506 | 0.33 K | 0.55 K | 6.4 K |
| CoalMine | 1,989 | 0.36 K | 1.6 K | 8.8 K |
| Fire, Fire2 (fire airways) | 147 | 1.1 K | 2.7 K | 11.5 K |
There is no independent check yet: Fire2's saved temperatures are the same as Fire's, so the pair used for airflow says nothing about heat. Moisture (latent heat, wet-bulb) and the change of rock heat with air temperature are not modelled; treat temperatures after large changes as an estimate.
contaminant_spread gives the steady-state concentration of a gas released in airways (m3/s of pure gas): c_out = c_in + G/Q, mixed by airflow at junctions, recirculation included. It is checked against exact hand calculations in the tests only: the mine examples hold time-dependent contaminant results, and the one steady result (dust in HVACDemoB) is in an HVAC model, which is not supported. Reading the model's own source inputs (include_file_sources=True, Base Injection x Base Concentration) is an unverified interpretation of Ventsim's fields and is off by default.
edit_airways accepts Width, Height, Length and kFactor. Area and perimeter follow the airway shape (rectangle, round; other profiles are scaled) and Resistance Total is scaled with the Atkinson relation R ~ k * P * L / A^3, so shock and density factors Ventsim folded into it are kept in proportion. add_airways copies an existing airway to new end points; it does not copy fans, fixed flows or pressures, heat or gas sources. A new end joins the network where it meets an existing airway end (not at a surface connection, which it would close); an end that meets nothing is a dead end unless listed in open_ends. Run simulate_airflow on the copy for the new airflow. Edited and added copies have not yet been opened in Ventsim itself; check them there before relying on them.
Issues and pull requests are welcome; see CONTRIBUTING.md. Questions and ideas go to Discussions.
pip install -e ".[test]"
pytest
MIT licence.