Prototype · Preview: every server in the official registry, synced every 30 minutes. Reviews and accounts come in a later step.
PopNx MCPMCP servers for people who use AI · explained in plain words

Zigbee2mqtt MCP

by alexpfauversion 0.7.0i★ –iRuns on your computer
Registry nameio.github.alexpfau/zigbee2mqtt-mcp

Install

Overview

Description from the maker (original English)

Administer a Zigbee2MQTT estate: health, mesh diagnostics, OTA, pairing, device management.

PopNx MCP’s three pillars

These three are never merged into one score: opinions, measurements and popularity are different things.

What you can do with it

We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.

  • Connection: Runs on your computer
  • Transport: stdio
  • Category: Clinics & health
  • You need to fill in: Z2M_MQTT_URL, Z2M_MQTT_PASSWORD

Install

Pick the AI app you use, then copy the settings.

Before you install

  • Basic checks: 1 of 1 passed
  • Runs on your computer with your user’s permissions (files, network, apps).
  • You fill in yourself: Z2M_MQTT_URL, Z2M_MQTT_USERNAME, Z2M_MQTT_PASSWORD, Z2M_BASE_TOPIC, Z2M_WRITE_MODE

Values marked secret are keys to your account. Never share them or paste them into a chat.

You need

  • npmNode.js installed (for the npx command)

Which app do you use?

Pick your app above. We remember it, so next time the button says “Install in …”.

Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json

{
  "mcpServers": {
    "zigbee2mqtt": {
      "command": "npx",
      "args": [
        "-y",
        "zigbee2mqtt-mcp"
      ],
      "env": {
        "Z2M_MQTT_URL": "your-value",
        "Z2M_MQTT_USERNAME": "your-value",
        "Z2M_MQTT_PASSWORD": "your-value",
        "Z2M_BASE_TOPIC": "your-value",
        "Z2M_WRITE_MODE": "your-value"
      }
    }
  }
}

Run this in your terminal

claude mcp add zigbee2mqtt --env Z2M_MQTT_URL=your-value --env Z2M_MQTT_USERNAME=your-value --env Z2M_MQTT_PASSWORD=your-value --env Z2M_BASE_TOPIC=your-value --env Z2M_WRITE_MODE=your-value -- npx -y zigbee2mqtt-mcp

Fill in the empty values before running it.

Open in Cursor

Or copy the settings yourself

Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json

{
  "mcpServers": {
    "zigbee2mqtt": {
      "command": "npx",
      "args": [
        "-y",
        "zigbee2mqtt-mcp"
      ],
      "env": {
        "Z2M_MQTT_URL": "your-value",
        "Z2M_MQTT_USERNAME": "your-value",
        "Z2M_MQTT_PASSWORD": "your-value",
        "Z2M_BASE_TOPIC": "your-value",
        "Z2M_WRITE_MODE": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

Open in VS Code

Or copy the settings yourself

Paste into .vscode/mcp.json in your project

{
  "servers": {
    "zigbee2mqtt": {
      "type": "stdio",
      "command": "npx",
      "args": [
        "-y",
        "zigbee2mqtt-mcp"
      ],
      "env": {
        "Z2M_MQTT_URL": "your-value",
        "Z2M_MQTT_USERNAME": "your-value",
        "Z2M_MQTT_PASSWORD": "your-value",
        "Z2M_BASE_TOPIC": "your-value",
        "Z2M_WRITE_MODE": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.

Your choice stays on this device in a cookie; no account needed.

Values you fill in

  • Z2M_MQTT_URL secret required env
    MQTT broker URL used by Zigbee2MQTT, e.g. mqtt://192.168.1.10:1883. Supports mqtt://, mqtts://, ws:// and wss://. This is the broker, not the Zigbee2MQTT frontend port.
  • Z2M_MQTT_USERNAME env
    MQTT broker username, if the broker requires authentication.
  • Z2M_MQTT_PASSWORD secret env
    MQTT broker password, if the broker requires authentication.
  • Z2M_BASE_TOPIC env
    Zigbee2MQTT base topic. Must match mqtt.base_topic in configuration.yaml. Defaults to zigbee2mqtt.
  • Z2M_WRITE_MODE env
    Tool exposure tier: off (read-only), safe (default; adds non-destructive writes such as pairing, options, rename and binding) or full (adds device removal, OTA flashing, Touchlink and bridge restart).

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 7, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account alexpfau, which owns the repo

  • … Not checked yet

    Still maintained

    We have not read this repo from GitHub yet

  • … Not checked yet

    Has a licence

    We have not read this repo from GitHub yet

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Compared with others in Clinics & healthi

  • More stars than 0% of the other 870 servers in this category
  • Published to the registry more recently than 29% of the other 870 servers in this category
  • Basic checks equal to or better than 100% of the other 870 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Zigbee2mqtt MCP safe?

It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

You need to fill in: Z2M_MQTT_URL, Z2M_MQTT_PASSWORD

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed –, and the latest version (0.7.0) reached the registry 3 months ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Node.js on your computer.

What can I use instead?

In the same category: Mirobody, FHIR MCP Server, Google Health MCP

Alternatives

Servers in the same category from other makers, sorted by stars.

Reading a card:★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

Mirobody

by thetahealth

Lab results to LOINC codes and UCUM units, symptoms and diagnoses to ICPC-3. Offline, no API key.

Runs on your computer★ 1,408Apache-2.0Updated 6 days ago
Install

MCP server providing seamless access to FHIR APIs for AI tools and healthcare applications

Runs on your computer★ 137Apache-2.0Updated 9 days ago
Install

Google Health MCP

by davidmosiah

Privacy-first unofficial Google Health API v4 MCP server for health, sleep, activity, HR agents

Runs on your computer★ 79MITUpdated 4 months ago
Install

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

zigbee2mqtt-mcp

A Model Context Protocol server for administering a Zigbee2MQTT estate.

Most Zigbee integrations already let an assistant turn a light on. This one is for the layer underneath: mesh health, weak links, devices that keep rejoining, stale batteries, firmware updates, pairing, binding, reporting intervals and device options — the things you normally open the Zigbee2MQTT frontend for.

It talks directly to the Zigbee2MQTT MQTT bridge API, so it works regardless of whether you use Home Assistant, Node-RED, openHAB or nothing at all. Tested against Zigbee2MQTT 2.x; several tools depend on bridge endpoints that only exist there, including bridge/health, device/binds/clear and the OTA scheduling topics.

Why this exists

If you already run Home Assistant, your Zigbee devices are exposed there and an assistant can control them. What Home Assistant does *not* expose is the bridge itself: link quality, mesh topology, interview state, OTA availability, permit_join, device options, bindings and reporting configuration. This server fills exactly that gap.

Design

  • No database. Zigbee2MQTT publishes its bridge topics as retained messages, so a fresh subscription yields a complete picture in a few hundred milliseconds. The server keeps only the latest payload per topic in memory.
  • No daemon. Pure stdio. It starts and dies with the MCP session.
  • Correlated requests. Every bridge/request/* carries a transaction id and is matched to its bridge/response/*, so concurrent calls cannot cross wires.
  • Tiered writes. Destructive operations are gated behind a write mode *and* an explicit confirm argument.

Install

Requires Node.js 22 or newer and network access to the MQTT broker that Zigbee2MQTT uses.

npx zigbee2mqtt-mcp
VS Code / GitHub Copilot

Add to your MCP configuration:

{

"servers": { "zigbee2mqtt": { "command": "npx", "args": ["-y", "zigbee2mqtt-mcp"], "env": { "Z2M_MQTT_URL": "mqtt://192.168.1.10:1883", "Z2M_MQTT_USERNAME": "mqtt", "Z2M_MQTT_PASSWORD": "${input:z2mPassword}" } } } }

Claude Desktop
{

"mcpServers": { "zigbee2mqtt": { "command": "npx", "args": ["-y", "zigbee2mqtt-mcp"], "env": { "Z2M_MQTT_URL": "mqtt://192.168.1.10:1883" } } } }

Point Z2M_MQTT_URL at your MQTT broker, not at the Zigbee2MQTT frontend port. If Zigbee2MQTT's configuration.yaml says mqtt.server: mqtt://192.168.1.10:1883, use that value verbatim.

Behind a corporate npm proxy? If npm config get registry is not https://registry.npmjs.org/, your proxy's upstream feed may not carry this package. Add an explicit override to the args rather than changing your global registry:

"args": ["-y", "--registry", "https://registry.npmjs.org/", "zigbee2mqtt-mcp"]

Configuration

VariableDefaultPurpose
Z2M_MQTT_URL*required*Broker URL. mqtt://, mqtts://, ws://, wss://
Z2M_MQTT_USERNAME / Z2M_MQTT_PASSWORD–Broker credentials
Z2M_BASE_TOPICzigbee2mqttMust match mqtt.base_topic
Z2M_MQTT_CLIENT_IDzigbee2mqtt-mcp- Override if your broker requires a fixed client ID
Z2M_WRITE_MODEsafeoff, safe or full
Z2M_LOG_LEVELerrorDiagnostics on stderr
Z2M_WEAK_LINK_THRESHOLD30Link quality below this is flagged
Z2M_LOW_BATTERY_THRESHOLD20Battery percentage below this is flagged
Z2M_STALE_HOURS24Hours of silence before a device is stale
Z2M_CONNECT_TIMEOUT_MS10000Broker connect timeout
Z2M_REQUEST_TIMEOUT_MS15000Default bridge request timeout
Z2M_MQTT_REJECT_UNAUTHORIZEDtrueSet false for self-signed TLS
Z2M_MQTT_CA / _CERT / _KEY–Paths to TLS material

Write modes

Tools above the active tier are not registered at all, so a model cannot reach for them.

ModeExposes
offRead-only tools
safeDefault. Read plus non-destructive writes: pairing, options, rename, configure, interview, binding, reporting, groups, state
fullEverything, including device removal, OTA flashing, Touchlink and bridge restart

Irreversible tools (z2m_remove_device, z2m_ota_update, z2m_touchlink, z2m_restart_bridge, z2m_set_bridge_options) additionally require confirm: true on every call. Three safe tools reduce state rather than only adding to it, so they are annotated destructive: z2m_rename_device, z2m_manage_group and z2m_bind. Their reducing actions also require confirm: true — z2m_manage_group (remove, remove_all_members) and z2m_bind (clear). z2m_rename_device is annotated destructive because it breaks anything referencing the old name, but stays unconfirmed since renaming back restores it.

Every tool also advertises MCP tool annotations so a client can decide what may run without prompting:

AnnotationMeaning here
readOnlyHint: trueThe nine read tools. They never change the network.
destructiveHint: truez2m_remove_device, z2m_ota_update, z2m_touchlink, z2m_restart_bridge, z2m_set_bridge_options, plus z2m_rename_device, z2m_manage_group and z2m_bind
idempotentHintTrue where repeating the call has no additional effect
openWorldHint: trueAlways — every tool reaches a live Zigbee network

Annotations describe the tool, not the tier: a safe tool can still be destructive. The tier decides what is registered, the annotation tells the client what to ask about.

Opt in to the destructive tier only when you want it:

"env": { "Z2M_WRITE_MODE": "full" }

Tools

Read
ToolPurpose
z2m_connection_statusBroker reachability, TLS posture and cached message counts — reports instead of throwing, even when nothing is configured yet
z2m_bridge_infoVersion, coordinator, channel, PAN ID, permit_join, restart_required, runtime stats
z2m_list_devicesFilter and sort devices by type, availability, link quality, battery, pending update
z2m_get_deviceExposes, settable options, endpoints, bindings, configured reportings, current state
z2m_health_reportWhole-estate audit in one call
z2m_network_mapMesh topology with parent, depth, link quality, orphan detection
z2m_list_groupsGroups, members and scenes
z2m_get_logsBridge logs and lifecycle events, buffered or watched live
z2m_coordinator_checkRouters missing from the coordinator's memory (Texas Instruments adapters only)
Safe writes

z2m_check_updates, z2m_permit_join, z2m_set_device_options, z2m_rename_device, z2m_configure_device, z2m_interview_device, z2m_set_state, z2m_manage_group, z2m_bind, z2m_configure_reporting

Full writes

z2m_remove_device, z2m_ota_update, z2m_restart_bridge, z2m_set_bridge_options, z2m_touchlink

Data availability caveats

Some fields depend on your Zigbee2MQTT configuration. The server detects what is available and tells you rather than silently returning nothing.

FieldRequiresIf missing
last_seenadvanced.last_seen set to e.g. ISO_8601 (default is disable)Staleness checks are skipped and a hint is returned
availabilityavailability.enabled: trueOffline detection is skipped and a hint is returned
linkquality, battery, updateLive device traffic — Zigbee2MQTT does not retain device state topicsPass collect_seconds to listen briefly, or use z2m_network_map for authoritative link quality
z2m_coordinator_checkAn adapter that supports coordinator backups (TI zStack, Silicon Labs EmberZNet; not deCONZ or ZiGate)Returns an error on unsupported adapters; z2m_bridge_info reports the expectation

Security notes

  • The broker URL may carry credentials (mqtt://user:pass@host). They are redacted everywhere the URL is echoed back to a model or written to a log, and error text from the MQTT client is scrubbed before it leaves the process. Zigbee2MQTT logs its own broker URL at startup, so lines relayed by z2m_get_logs are scrubbed too.
  • safe mode can actuate anything on the mesh via z2m_set_state, including locks, valves and sirens. Use off if that matters.
  • z2m_permit_join opens the network to any nearby Zigbee device for the duration of the window. It is in safe because it is routine and reversible, but it is a security boundary.

Example prompts

  • "Is my Zigbee network healthy?"
  • "Which devices have the weakest signal?"
  • "Which batteries need replacing?"
  • "Any firmware updates available?"
  • "Open the network for pairing via the kitchen router for two minutes."
  • "This sensor stopped reporting temperature — fix it."
  • "Bind the hallway remote to the hallway light so it works if the bridge is down."

Development

npm install

npm run build npm run watch

Unit tests. No broker required; they run on every push across Node 22 and 24.

npm test

Manual smoke test against a real instance

Z2M_MQTT_URL=mqtt://192.168.1.10:1883 node scripts/smoke.mjs Z2M_MQTT_URL=mqtt://192.168.1.10:1883 node scripts/smoke.mjs z2m_list_devices '{"only_problems":true}'

Sequential read-after-write test. Renames a device and creates a group, then

restores both, including on failure. Set Z2M_TEST_DEVICE to pick the device,

or ROUNDTRIP_GROUPS_ONLY=1 to skip the rename.

Z2M_MQTT_URL=mqtt://192.168.1.10:1883 node scripts/roundtrip.mjs

Note that an MCP server may receive requests concurrently. When testing ordering, await each response before sending the next, as roundtrip.mjs does — piping several requests at once will produce misleading results.

The unit tests cover health classification, capability detection, topic routing, write-mode gating and configuration parsing. They are broker-free by design, so anything that needs a live mesh belongs in scripts/ instead.

A passing suite only proves the tests ran, so scripts/mutate.mjs breaks the source one change at a time and checks the suite notices each one:

node scripts/mutate.mjs          # every mutant

node scripts/mutate.mjs redact # only mutants whose name matches

A surviving mutant marks behavior nothing actually tests, and exits non-zero. Add a mutant alongside any fix worth keeping fixed.

Releases are tag-driven: npm version then git push --follow-tags. CI publishes to npm with provenance, rewrites server.json's version from the tag and publishes to the MCP Registry, then creates the GitHub release. The version committed in server.json is therefore not authoritative — the tag is.

Safety

This server can remove devices from your network and flash firmware. Both are irreversible and OTA failures can brick hardware. Those tools live in the full tier, which is not enabled by default — you must opt in with Z2M_WRITE_MODE=full. Broker credentials are read from the environment and never logged.

Status

Early re

Only the beginning is shown; read the rest in the repo

Ask PopNx