Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Description from the maker (original English)
MCP server for Tecan Cavro syringe pumps (XLP 6000, XMP 6000, XCalibur) over the DT protocol.
These three are never merged into one score: opinions, measurements and popularity are different things.
We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.
Pick the AI app you use, then copy the settings.
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITSYou need
Which app do you use?
Pick your app above. We remember it, so next time the button says “Install in …”.
Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json
{
"mcpServers": {
"labmcp-cavro": {
"command": "uvx",
"args": [
"labmcp-cavro"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Run this in your terminal
claude mcp add labmcp-cavro --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-cavroFill in the empty values before running it.
Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-cavro": {
"command": "uvx",
"args": [
"labmcp-cavro"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.
Paste into .vscode/mcp.json in your project
{
"servers": {
"labmcp-cavro": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-cavro"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.
This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.
Your choice stays on this device in a cookie; no account needed.
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envThese settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
We have not read this repo from GitHub yet
We have not read this repo from GitHub yet
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed –, and the latest version (0.1.3) reached the registry 43 days ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: Spec Driven Development, Remote Desktop Commander, VMware Storage
Servers in the same category from other makers, sorted by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
VMware vSphere storage with 16 MCP tools: datastores, iSCSI, vSAN, FC multipath.
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent initialize, aspirate and dispense microlitre volumes at set flow rates, switch valve ports and stop Tecan Cavro OEM syringe pumps through the documented Cavro Data Terminal (DT) protocol.
| Package | labmcp-cavro |
| Instruments | Cavro XLP 6000, Cavro XMP 6000, Cavro XCalibur (with 3-port, 4-port or distribution valves, or valveless) |
| Interfaces | RS-232, RS-485 (with an RS-485 adapter), serial-to-Ethernet adapters |
| Protocol | Cavro DT protocol (XLP 6000 Operating Manual, 734237-C, chapter 3 and appendix G); step resolution per Tecan XCalibur / XMP 6000 specifications |
| Status | 🧪 simulated: tested against a wire-level simulator, not yet verified on hardware. Report a hardware test |
uvx labmcp-cavro --simulate --check
The simulator is an XLP 6000 with a 1 mL syringe and a 3-port valve. Moves take real time; add --option sim_speed=10 to speed it up.
1, switch 1 is 2, … switch 8 is 9, switches 9–E are : ; < = > ?). The pump detects DT versus OEM protocol from the first message after power-up. The default is 9600 baud, 8N1; 38400 baud is selected with the U47 configuration command.--option syringe_ul=1000: syringe volume in µL.--option model=xlp6000 (or xmp6000, 6000 increments per stroke; xcalibur, 3000). For another DT-compatible pump, give --option steps_per_stroke= instead.--option resolution=fine (N1, 8× finer volume steps; applied by initialize) and --option pump_address=2.uvx labmcp ports uvx labmcp-cavro --address /dev/ttyUSB0 --option syringe_ul=1000 --option model=xcalibur --check
uvx labmcp-cavro --address COM3 --option syringe_ul=500 --option model=xlp6000 --check
Non-default baud rates go in the address: `serial://COM3?baudrate=38400`.
Claude Code
claude mcp add cavro -- uvx labmcp-cavro --address /dev/ttyUSB0 --option syringe_ul=1000 --option model=xcalibur
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "cavro": { "command": "uvx", "args": ["labmcp-cavro", "--address", "/dev/ttyUSB0", "--option", "syringe_ul=1000", "--option", "model=xcalibur"] } } }
Add --read-only to allow status reads but block every move.
| Tool | Kind | Description |
|---|---|---|
aspirate_ul | ⚠️ hazard | Draw volume_ul into the syringe at flow_ul_s through the current (or given) valve port, and wait until the move has finished. The pump must be initialized and have room for the volume. |
dispense_ul | ⚠️ hazard | Push volume_ul out of the syringe at flow_ul_s through the current (or given) valve port, and wait until the move has finished. The syringe must contain at least that volume. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_status | 👁 read | Report whether the pump is ready or busy, any error (decoded), the plunger position as the volume in the syringe, the valve position, resolution mode and current top speed. |
initialize | ⚠️ hazard | Initialize the pump: drive the plunger to the top of the syringe (expelling its contents through the valve), set that as position 0 and home the valve. Needed after power-up, a plunger overload or terminate. Route the valve output to waste first. Takes a few seconds. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_valve | ⚠️ hazard | Turn the valve to a named position (3/4-port valves) or to a numbered port (distribution valves). In bypass the plunger cannot move. Returns the new status. |
terminate | 🛑 safety | Stop any plunger move, loop or delay immediately (DT command T). A valve move in progress still completes. Re-initialize afterwards: the plunger may have lost steps. |
| Limit | Default | Meaning |
|---|---|---|
max_volume_ul | 5000 µL | Largest volume one aspirate_ul/dispense_ul may move |
max_flow_ul_s | 500 µL/s | Highest plunger flow rate an agent may use |
Override at launch: --limit max_flow_ul_s=50. Independently of the limits, the server refuses moves that would overfill or over-empty the syringe, and flows the pump cannot produce with the installed syringe (top speed 5–6000 pulses/s).
?28) before every move. Top speed V = flow × 6000 ÷ syringe volume: on all three models a full stroke is 6000 speed pulses in N0/N1. For the XCalibur this is derived from Tecan's published 1.2 s–20 min per stroke, not from its operating manual; please confirm on hardware.Q, as the manual requires. Invalid commands are reported immediately; invalid operands (e.g. a move past the end of the syringe) are reported by the next Q, and the server turns both into clear errors.T without R: in the DT command set R resumes a terminated string. T does not stop a valve move in progress. Re-initialize after terminating. If a move or initialization is still busy well past its expected duration (1.5× + 10 s), or the link fails while waiting, the server sends T itself instead of leaving the plunger moving.--option steps_per_stroke=…, but they are untested.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |