Prototype · Preview: every server in the official registry, synced every 30 minutes. Reviews and accounts come in a later step.
PopNx MCPMCP servers for people who use AI · explained in plain words

Tecan Cavro Syringe Pump

by K-Dense-AIversion 0.1.3i★ –iRuns on your computer
Registry nameio.github.K-Dense-AI/labmcp-cavro

Install

Overview

Description from the maker (original English)

MCP server for Tecan Cavro syringe pumps (XLP 6000, XMP 6000, XCalibur) over the DT protocol.

PopNx MCP’s three pillars

These three are never merged into one score: opinions, measurements and popularity are different things.

What you can do with it

We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.

  • Connection: Runs on your computer
  • Transport: stdio
  • Category: Other

Install

Pick the AI app you use, then copy the settings.

Before you install

  • Basic checks: 1 of 1 passed
  • Runs on your computer with your user’s permissions (files, network, apps).
  • You fill in yourself: LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS

You need

  • PyPIPython’s uv installed (for the uvx command)

Which app do you use?

Pick your app above. We remember it, so next time the button says “Install in …”.

Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json

{
  "mcpServers": {
    "labmcp-cavro": {
      "command": "uvx",
      "args": [
        "labmcp-cavro"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Run this in your terminal

claude mcp add labmcp-cavro --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-cavro

Fill in the empty values before running it.

Open in Cursor

Or copy the settings yourself

Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json

{
  "mcpServers": {
    "labmcp-cavro": {
      "command": "uvx",
      "args": [
        "labmcp-cavro"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

Open in VS Code

Or copy the settings yourself

Paste into .vscode/mcp.json in your project

{
  "servers": {
    "labmcp-cavro": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-cavro"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.

Your choice stays on this device in a cookie; no account needed.

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • … Not checked yet

    Still maintained

    We have not read this repo from GitHub yet

  • … Not checked yet

    Has a licence

    We have not read this repo from GitHub yet

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Compared with others in Otheri

  • More stars than 0% of the other 18606 servers in this category
  • Published to the registry more recently than 52% of the other 18606 servers in this category
  • Basic checks equal to or better than 100% of the other 18606 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Tecan Cavro Syringe Pump safe?

It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed –, and the latest version (0.1.3) reached the registry 43 days ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: Spec Driven Development, Remote Desktop Commander, VMware Storage

Alternatives

Servers in the same category from other makers, sorted by stars.

Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

Spec Driven Development

MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.

by formulahendryEarly↓ 66/wk★ 440Updated 14 months ago

Runs on your computer

Remote Desktop Commander

Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.

by desktop-commanderGrowing★ 211Updated 3 days ago

Runs in the cloud✓ desktopcommander.app

VMware Storage

VMware vSphere storage with 16 MCP tools: datastores, iSCSI, vSAN, FC multipath.

by vmware-skillsVery new↓ 322/wkUpdated today

Runs on your computer

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Tecan Cavro Syringe Pump — MCP Server

Let an AI agent initialize, aspirate and dispense microlitre volumes at set flow rates, switch valve ports and stop Tecan Cavro OEM syringe pumps through the documented Cavro Data Terminal (DT) protocol.

Packagelabmcp-cavro
InstrumentsCavro XLP 6000, Cavro XMP 6000, Cavro XCalibur (with 3-port, 4-port or distribution valves, or valveless)
InterfacesRS-232, RS-485 (with an RS-485 adapter), serial-to-Ethernet adapters
ProtocolCavro DT protocol (XLP 6000 Operating Manual, 734237-C, chapter 3 and appendix G); step resolution per Tecan XCalibur / XMP 6000 specifications
Status🧪 simulated: tested against a wire-level simulator, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-cavro --simulate --check

The simulator is an XLP 6000 with a 1 mL syringe and a 3-port valve. Moves take real time; add --option sim_speed=10 to speed it up.

Connect your pump

  1. Pump setup: set the address switch (switch 0 is DT address 1, switch 1 is 2, … switch 8 is 9, switches 9–E are : ; < = > ?). The pump detects DT versus OEM protocol from the first message after power-up. The default is 9600 baud, 8N1; 38400 baud is selected with the U47 configuration command.
  2. Tell the server what is installed. The pump cannot report its syringe, so these options are required on real hardware:
  • --option syringe_ul=1000: syringe volume in µL.
  • --option model=xlp6000 (or xmp6000, 6000 increments per stroke; xcalibur, 3000). For another DT-compatible pump, give --option steps_per_stroke= instead.
  • Optional: --option resolution=fine (N1, 8× finer volume steps; applied by initialize) and --option pump_address=2.
  1. Find the port: uvx labmcp ports
  2. Test the connection:
   uvx labmcp-cavro --address /dev/ttyUSB0 --option syringe_ul=1000 --option model=xcalibur --check

uvx labmcp-cavro --address COM3 --option syringe_ul=500 --option model=xlp6000 --check

   Non-default baud rates go in the address: `serial://COM3?baudrate=38400`.

Add to your MCP client

Claude Code

claude mcp add cavro -- uvx labmcp-cavro --address /dev/ttyUSB0 --option syringe_ul=1000 --option model=xcalibur

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "cavro": { "command": "uvx", "args": ["labmcp-cavro", "--address", "/dev/ttyUSB0", "--option", "syringe_ul=1000", "--option", "model=xcalibur"] } } }

Add --read-only to allow status reads but block every move.

Tools

ToolKindDescription
aspirate_ul⚠️ hazardDraw volume_ul into the syringe at flow_ul_s through the current (or given) valve port, and wait until the move has finished. The pump must be initialized and have room for the volume.
dispense_ul⚠️ hazardPush volume_ul out of the syringe at flow_ul_s through the current (or given) valve port, and wait until the move has finished. The syringe must contain at least that volume.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_status👁 readReport whether the pump is ready or busy, any error (decoded), the plunger position as the volume in the syringe, the valve position, resolution mode and current top speed.
initialize⚠️ hazardInitialize the pump: drive the plunger to the top of the syringe (expelling its contents through the valve), set that as position 0 and home the valve. Needed after power-up, a plunger overload or terminate. Route the valve output to waste first. Takes a few seconds.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_valve⚠️ hazardTurn the valve to a named position (3/4-port valves) or to a numbered port (distribution valves). In bypass the plunger cannot move. Returns the new status.
terminate🛑 safetyStop any plunger move, loop or delay immediately (DT command T). A valve move in progress still completes. Re-initialize afterwards: the plunger may have lost steps.

Safety limits

LimitDefaultMeaning
max_volume_ul5000 µLLargest volume one aspirate_ul/dispense_ul may move
max_flow_ul_s500 µL/sHighest plunger flow rate an agent may use

Override at launch: --limit max_flow_ul_s=50. Independently of the limits, the server refuses moves that would overfill or over-empty the syringe, and flows the pump cannot produce with the installed syringe (top speed 5–6000 pulses/s).

Example prompts

  • "Initialize the pump, then prime it: aspirate 1 mL from the input port and dispense it to the output port, three times."
  • "Aspirate 150 µL of sample slowly (20 µL/s) from port 3 and dispense 50 µL into port 5."
  • "How much liquid is in the syringe right now and which port is the valve on?"
  • "The pump reported a plunger overload. What does that mean and what should I check?"
  • "Stop the pump now."

Notes

  • Conversion. Steps = volume × steps-per-stroke ÷ syringe volume, where steps-per-stroke is 6000 (XLP/XMP) or 3000 (XCalibur) in standard mode and 8× that in fine-positioning mode (N1). The mode is read from the pump (?28) before every move. Top speed V = flow × 6000 ÷ syringe volume: on all three models a full stroke is 6000 speed pulses in N0/N1. For the XCalibur this is derived from Tecan's published 1.2 s–20 min per stroke, not from its operating manual; please confirm on hardware.
  • Busy/ready is read only from Q, as the manual requires. Invalid commands are reported immediately; invalid operands (e.g. a move past the end of the syringe) are reported by the next Q, and the server turns both into clear errors.
  • Initialization force is chosen from the syringe size (full ≥ 1 mL, half for 250/500 µL, third for 50/100 µL; manual table 3-6) unless you pick one.
  • `terminate` sends T without R: in the DT command set R resumes a terminated string. T does not stop a valve move in progress. Re-initialize after terminating. If a move or initialization is still busy well past its expected duration (1.5× + 10 s), or the link fails while waiting, the server sends T itself instead of leaving the plunger moving.
  • The server does not use microstep mode (N2), the OEM protocol (checksums, sequence numbers) or CAN.
  • Cavro Centris has a different resolution (181,490 increments per stroke) and volume-based firmware commands that we could not verify, so it is not supported. XE 1000 and older XL/XP 3000 pumps may work with --option steps_per_stroke=…, but they are untested.

Hardware verification

ModelFirmwareInterfaceVerified byDate
*none yet: be the first*
Ask PopNx