MCP server for microscopes controlled by Micro-Manager (pymmcore-plus).

PopNx MCP’s three pillars

These three are never merged into one score: opinions, measurements and popularity are different things.

What you can do with it

We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.

  • Connection: Runs on your computer
  • Transport: stdio
  • Category: Other

Install

Pick the AI app you use, then copy the settings.

Before you install

  • Basic checks: 1 of 1 passed
  • Runs on your computer with your user’s permissions (files, network, apps).
  • You fill in yourself: LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS

You need

  • PyPIPython’s uv installed (for the uvx command)

Which app do you use?

Pick your app above. We remember it, so next time the button says “Install in …”.

Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json

{
  "mcpServers": {
    "labmcp-micro-manager": {
      "command": "uvx",
      "args": [
        "labmcp-micro-manager"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Run this in your terminal

claude mcp add labmcp-micro-manager --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-micro-manager

Fill in the empty values before running it.

Open in Cursor

Or copy the settings yourself

Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json

{
  "mcpServers": {
    "labmcp-micro-manager": {
      "command": "uvx",
      "args": [
        "labmcp-micro-manager"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

Open in VS Code

Or copy the settings yourself

Paste into .vscode/mcp.json in your project

{
  "servers": {
    "labmcp-micro-manager": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-micro-manager"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.

Your choice stays on this device in a cookie; no account needed.

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • … Not checked yet

    Still maintained

    We have not read this repo from GitHub yet

  • … Not checked yet

    Has a licence

    We have not read this repo from GitHub yet

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Compared with others in Otheri

  • More stars than 0% of the other 18398 servers in this category
  • Published to the registry more recently than 53% of the other 18398 servers in this category
  • Basic checks equal to or better than 100% of the other 18398 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Micro-Manager Microscope safe?

It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed –, and the latest version (0.1.3) reached the registry 42 days ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: Spec Driven Development, Remote Desktop Commander, Tethered Trust

Alternatives

Servers in the same category from other makers, sorted by stars.

Reading a card:★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

Spec Driven Development

by formulahendry

MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.

Runs on your computer★ 440MITUpdated 14 months ago
Install

Remote Desktop Commander

by desktop-commander

Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.

Runs in the cloud★ 211Updated 3 days ago
Install

Tethered Trust

by tetheredtrust.com

Fit, compatibility and recall checks for AI agents before they buy: verdicts, evidence, receipts.

Runs in the cloudUpdated today
Install

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Micro-Manager Microscope — MCP Server

Let an AI agent snap images, acquire z-stacks and time-lapses, move the stage and focus within limits you set, switch channels and objectives, set exposure, operate shutters and run autofocus on any microscope controlled by Micro-Manager, through its open device layer (MMCore) and pymmcore-plus.

Packagelabmcp-micro-manager
InstrumentsAny hardware with a Micro-Manager device adapter (hundreds of cameras, XY/Z stages, microscope stands, filter wheels, shutters and light sources from Hamamatsu, Photometrics, Andor, PCO, Basler, ASI, Prior, Ludl, Märzhäuser, Nikon, Zeiss, Olympus/Evident, Leica, Lumencor, CoolLED and others), described by a Micro-Manager .cfg hardware configuration
InterfacesWhatever the device adapters use: USB, serial, Camera Link / CoaXPress / GigE frame grabbers
ProtocolMicro-Manager MMCore API via pymmcore-plus CMMCorePlus (MMCore API reference, pymmcore-plus API, configuration guide)
Status🧪 simulated: tested against a simulated microscope and against pymmcore-plus' real core with Python test devices, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-micro-manager --simulate --check

The simulator is a widefield fluorescence microscope with a 512 x 512, 12-bit camera, an XY stage, a focus drive, a shutter, a DAPI / FITC / TRITC / Brightfield filter wheel, a 10x / 20x / 40x turret and a hardware autofocus, looking at a field of cell nuclei. Its images defocus with Z, scale with exposure, bleach with light dose, saturate at 4095 and carry shot and read noise, so focusing, exposure and bleaching behave like on a real microscope.

Connect your microscope

  1. Hardware configuration: create and test a .cfg file with Micro-Manager's Hardware Configuration Wizard (in the Micro-Manager app), including config groups for channels (usually Channel) and objectives (Objective) and a pixel-size calibration. Close the Micro-Manager app afterwards: a device can only be opened by one program.
  2. Device adapters: pymmcore-plus needs Micro-Manager's device adapter libraries in a version that matches its pymmcore build. Either download them with pymmcore-plus' own installer:
   uvx --from labmcp-micro-manager mmcore install     # into pymmcore-plus' data folder

uvx --from labmcp-micro-manager mmcore list # show what was found

   or point to an existing Micro-Manager installation with `--option mm_path=/path/to/Micro-Manager` (it must be a build whose device interface matches pymmcore; `mmcore info` shows the version). Vendor camera SDKs and drivers must be installed separately, as for Micro-Manager itself.
  1. Test the connection:
   uvx labmcp-micro-manager --address ~/scopes/Ti2_Prime95B.cfg --check

uvx labmcp-micro-manager --address MMConfig_demo.cfg --check # Micro-Manager demo devices

   `--check` loads the configuration and prints the camera, stages and other device roles.

Add to your MCP client

Claude Code

claude mcp add microscope -- uvx labmcp-micro-manager --address /path/to/MyScope.cfg --option z_min_um=0 --option z_max_um=4500

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "microscope": { "command": "uvx", "args": ["labmcp-micro-manager", "--address", "/path/to/MyScope.cfg", "--option", "z_min_um=0", "--option", "z_max_um=4500", "--option", "data_dir=/data/microscope"] } } }

Add --read-only to let the agent read positions and settings without imaging or moving anything (stop_stage and close_shutter stay available). For other clients, generate the snippet with uvx labmcp config micro-manager --address /path/to/MyScope.cfg --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
acquire_time_lapse⚠️ hazardAcquire a time-lapse at the current position: images every interval_s (optionally several channels per timepoint), saves a multi-page TIFF and reports per-frame statistics and the intensity change (bleaching). Bounded by max_frames and max_acquisition_duration_s; stop_stage aborts it.
acquire_z_stack⚠️ hazardAcquire a z-stack around the current focus: moves Z through the slices (optionally imaging several channels at each), saves a multi-page TIFF, reports per-slice statistics and the sharpest slice, and returns Z to where it started. Every slice must stay within max_z_step_um of the start and the Z soft limits.
autofocus⚠️ hazardRun the configured autofocus device (e.g. a hardware focus lock) once; it moves the focus drive. If the result is outside the Z step or soft limits, the focus is moved back and an error is raised.
close_shutter🛑 safetyClose the shutter (stop illuminating the sample) and abort any running acquisition.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_exposure👁 readReturn the camera exposure time in milliseconds.
get_position👁 readRead the XY stage and focus (Z) positions in micrometres, and which way increasing Z moves the objective.
get_system_info👁 readDescribe the microscope: loaded devices (camera, stages, shutters, filter wheels...), which device has which role, camera size/bit depth/exposure, pixel size, config groups with their presets, the current position, and the soft limits. Call this first.
list_config_groups👁 readList Micro-Manager config groups (e.g. Channel, Objective) with their presets and the preset currently active.
move_stage_xy⚠️ hazardMove the XY stage. Moves longer than max_xy_step_um or outside the XY soft limits are refused before anything moves. Make sure the objective and condenser clear the sample holder.
move_z⚠️ hazardMove the focus drive (Z). Moving the objective toward the sample can crash it into the slide: moves larger than max_z_step_um or outside the Z soft limits are refused before anything moves.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_config🎛 controlApply a config-group preset (e.g. switch the channel: filter cube, light source, emission filter). Objective/turret groups are refused here: use set_objective.
set_exposure🎛 controlSet the camera exposure time (ms). Longer exposures give brighter images but more photobleaching. Returns the exposure the camera accepted.
set_objective⚠️ hazardSwitch the objective (rotates the nosepiece/turret). A longer or immersion objective can hit the sample holder or need oil/water: confirm with the user first. Pixel size changes with the objective.
set_shutter⚠️ hazardOpen or close the current shutter, and optionally switch auto-shutter. An open shutter illuminates (and bleaches) the sample until it is closed again.
snap_image🎛 controlAcquire one image with the current channel, exposure and position. The sample is illuminated during the exposure. Saves the full image as TIFF and returns summary statistics (min/max/mean, saturation, sharpness) plus an optional contrast-stretched preview.
stop_stage🛑 safetyImmediately stop XY and Z stage motion and abort any z-stack or time-lapse in progress.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. get_command_log lists every state-changing MMCore call (setPosition(1502.0), setConfig('Channel', 'FITC'), snapImage(), ...).

Safety limits

LimitDefaultMeaning
max_z_step_um50 µmLargest focus move from the current position (also the largest z-stack offset, and the largest autofocus correction accepted)
max_xy_step_um20000 µmLargest XY stage move in one call (straight-line distance)
max_exposure_ms10000 msLongest camera exposure
max_frames500Most images in one z-stack or time-lapse (slices or timepoints x channels)
max_acquisition_duration_s3600 sLongest time-lapse (one tool call can run at most 3600 s whatever this is set to)

Override at launch, e.g. --limit max_z_step_um=10 --limit max_frames=2000.

Soft limits (recommended): absolute stage bounds in micrometres, set with driver options. Find them by moving to the safe extremes in Micro-Manager (e.g. Z with the objective just below the coverslip) and reading the positions:

OptionMeaning
z_min_um, z_max_umAllowed focus range. Set the side that moves the objective toward the sample tightly.
x_min_um, x_max_um, y_min_um, y_max_umAllowed XY range (e.g. the area of your slide or plate holder)

Every Z and XY move, every z-stack slice and every autofocus result is checked against the step limits and soft limits before anything moves (autofocus results are checked afterwards and undone if out of range).

Example prompts

  • "What's on this microscope? List the channels and objectives, and the current position."
  • "Switch to FITC, find an exposure that uses about half the camera's range without saturating, then snap an image and show me."
  • "Autofocus, then take a z-stack from −10 to +10 µm in 1 µm steps in DAPI and FITC and tell me which slice is sharpest."
  • "Move 500 µm to the right and snap a DAPI image; repeat three more times to make a row of four fields."
  • "Record a time-lapse in TRITC every 30 s for 20 minutes and tell me how much the signal bleached."
  • "Something is wrong — stop the stage and close the shutter."

Notes

  • Objective crashes. Moving the focus drive toward the sample can drive the objective into the coverslip or dish. get_position / get_system_info report focus_direction (whether increasing Z moves the objective toward the sample, as declared by the device adapter; often unknown). Configure z_min_um / z_max_um for every microscope you connect.
  • Objective changes (set_objective) rotate the nosepiece and are marked as hazardous; set_config refuses config groups whose names look like objective or turret groups (Objective, Nosepiece, Turret, Magnification, Lens). Other groups are applied as-is: if one of your presets moves hardware near the sample, name the group accordingly or leave it out of the configuration.
  • Light exposure. With auto-shutter on (the default), the light path only opens while the camera exposes. set_shutter(open=True) leaves the sample lit until close_shutter is called.
  • Images are saved as TIFF files (ImageJ hyperstacks with pixel size, Z spacing and frame interval) in save_path, or in --option data_dir=... (default: the system temp folder, labmcp-micro-manager/). save_path must end in .tif/.tiff and must not be a folder; it is checked before anything moves or is exposed. Existing files are never overwritten (a numeric suffix is added). Tools return statistics (min/max/mean/std, saturated fraction, a sharpness score) and a small contrast-stre

Only the beginning is shown; read the rest in the repo