MCP server for Modbus TCP/RTU devices with typed, scaled register maps and per-point limits.

PopNx MCP’s three pillars

These three are never merged into one score: opinions, measurements and popularity are different things.

What you can do with it

We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.

  • Connection: Runs on your computer
  • Transport: stdio
  • Category: Travel, maps & weather

Install

Pick the AI app you use, then copy the settings.

Before you install

  • Basic checks: 1 of 1 passed
  • Runs on your computer with your user’s permissions (files, network, apps).
  • You fill in yourself: LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS

You need

  • PyPIPython’s uv installed (for the uvx command)

Which app do you use?

Pick your app above. We remember it, so next time the button says “Install in …”.

Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json

{
  "mcpServers": {
    "labmcp-modbus": {
      "command": "uvx",
      "args": [
        "labmcp-modbus"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Run this in your terminal

claude mcp add labmcp-modbus --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-modbus

Fill in the empty values before running it.

Open in Cursor

Or copy the settings yourself

Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json

{
  "mcpServers": {
    "labmcp-modbus": {
      "command": "uvx",
      "args": [
        "labmcp-modbus"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

Open in VS Code

Or copy the settings yourself

Paste into .vscode/mcp.json in your project

{
  "servers": {
    "labmcp-modbus": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-modbus"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.

Your choice stays on this device in a cookie; no account needed.

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • … Not checked yet

    Still maintained

    We have not read this repo from GitHub yet

  • … Not checked yet

    Has a licence

    We have not read this repo from GitHub yet

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Compared with others in Travel, maps & weatheri

  • More stars than 0% of the other 1718 servers in this category
  • Published to the registry more recently than 42% of the other 1718 servers in this category
  • Basic checks equal to or better than 100% of the other 1718 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Modbus TCP/RTU Device safe?

It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed –, and the latest version (0.1.3) reached the registry 42 days ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: DogPolicies, London Foster Realty LLC, Cajon.pro

Alternatives

Servers in the same category from other makers, sorted by stars.

Reading a card:★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

DogPolicies

by xultrax-web

Verified dog rules for California and Nevada travel: parks, beaches, hotels, fees, sourced and dated

Computer or cloudUpdated today
Install

London Foster Realty LLC

by app.getrealtymind.com

Book a real estate consultation with London Foster Realty LLC. Areas, open times, booking.

Runs in the cloudUpdated today
Install

Cajon.pro

by cajon.pro

Drum schools map (Russia, Kazakhstan, Armenia, Belarus), song tempo and drum parts, cajons.

Runs in the cloudUpdated today
Install

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Modbus TCP/RTU Device — MCP Server

Let an AI agent read and control Modbus devices over Ethernet (Modbus TCP) or RS-485/RS-232 (Modbus RTU/ASCII): PID temperature controllers, recirculating chillers, PLCs, process sensors, VFDs and data loggers. You describe the device once in a register map (YAML or JSON). The agent then works with named points in real units, such as process_temperature = 37.2 °C or setpoint, instead of raw registers. The server enforces the map's rules: only writable points can be written by name, every writable number must have a min and max, and out-of-range values are refused before anything is sent. The map can also define a safe state, a list of point writes (heater off, controller to standby) that a SAFETY tool runs on request.

Packagelabmcp-modbus
InstrumentsAny Modbus device: temperature controllers (Watlow, Eurotherm, Omega, Autonics, …), chillers and circulators, PLCs and remote I/O, sensors/transmitters, VFDs, power meters, data loggers
InterfacesEthernet (Modbus TCP, port 502), RS-485 / RS-232 (Modbus RTU or ASCII), serial-to-Ethernet gateways (RTU over TCP)
ProtocolMODBUS Application Protocol Specification V1.1b3, MODBUS over Serial Line V1.02, MODBUS Messaging on TCP/IP Implementation Guide V1.0b; client via pymodbus 3.8+
Status🧪 simulated: tested against an in-memory simulated controller and a local pymodbus server, not yet verified on hardware. Report a hardware test

What this server adds over a plain register-poking Modbus MCP:

  • Typed register maps: int16/uint16/int32/uint32/float32/float64/bool, word and byte order, scale and offset, units, enums (0 = standby, 1 = auto) and descriptions.
  • Per-point limits: writable points need min/max or an enum, and values are checked before sending. Raw writes to addresses that belong to a mapped point are refused, so the limits can't be bypassed.
  • Read-back: every write_point reads the value back and reports whether it matches.
  • Safe state: an apply_safe_state SAFETY tool, defined in the map, that works even in --read-only mode.
  • Read-only mode (--read-only), an audit log of every request and reply, and bounded request sizes.

Try it without hardware

uvx labmcp-modbus --simulate --check

The simulator is a generic single-loop PID temperature controller. Its layout is the bundled example register map. It is illustrative and not a copy of any vendor's map. A heater (3 °C/s at full power) heats a thermal mass that cools towards a 22 °C room (τ = 90 s). The PID loop has a ramping working setpoint and alarm bits. The simulator answers exception 02 for unimplemented addresses, 03 for values outside its own range (e.g. a 500 °C setpoint), and 0B for a wrong unit id. With --simulate --option register_map=my_map.yaml, points that are not in the example layout get zero-initialised storage, so you can test your own map.

Connect your device

  1. Device setup: in the device's communications menu, enable Modbus and note its settings.
  • RTU (RS-485): set the unit (slave) address (1–247), baud rate, parity and stop bits. The server defaults to the Modbus serial default of 19200 baud, 8 data bits, even parity, 1 stop bit. Many devices ship with other settings (e.g. 9600 8N1); put your device's settings in the address. Wire the USB-RS485 adapter's A/B (D−/D+) lines to the device; vendors disagree on the A/B labels, so swap them if nothing answers. Connect the signal ground, and put 120 Ω termination at both ends of longer buses.
  • TCP: set the IP address. The port is 502 unless changed. Many TCP devices ignore the unit id. If yours does not, it is usually 1; the TCP implementation guide recommends 255 for directly addressed devices.
  1. Write a register map for your device from its Modbus manual. Copy the example and see Register map below.
  2. Test the connection:
   uvx labmcp-modbus --address tcp://192.168.1.20:502 --option register_map=~/maps/oven.yaml --check

uvx labmcp-modbus --address "serial:///dev/ttyUSB0?baudrate=9600&parity=N" --option unit_id=3 \ --option register_map=~/maps/controller.yaml --check uvx labmcp-modbus --address "serial://COM4?baudrate=19200&parity=E" --option register_map=C:/maps/chiller.json --check uvx labmcp-modbus --address "tcp://192.168.1.30:4001?framer=rtu" --check # RTU through a transparent gateway

   `--check` connects, reads the map's first point as a probe and prints `probe: ok: …` or the error. More address parameters: `stopbits=2`, `bytesize=7`, `framer=ascii` (Modbus ASCII), `timeout=1`, `retries=2`.

Register map

device:                 # optional

name: Incubator oven manufacturer: Example model: X-100 unit_id: 1 # --option unit_id overrides it word_order: big # default for 32/64-bit points byte_order: big

points: chamber_temperature: table: input # holding | input | coil | discrete address: 0 # 0-based protocol address ("30001" in the manual -> input 0) type: int16 # uint16 | int16 | uint32 | int32 | float32 | float64 | bool scale: 0.1 # value = raw * scale + offset unit: °C description: Chamber temperature setpoint: table: holding address: 0 # "40001" -> holding 0 type: int16 scale: 0.1 unit: °C writable: true min: 20 # required for writable numbers: checked before sending max: 60 mode: table: holding address: 1 writable: true enum: {0: standby, 1: run} heater_enable: table: coil address: 0 writable: true

safe_state: # optional: run in order by apply_safe_state

  • {point: heater_enable, value: false}
  • {point: mode, value: standby}
FieldDefaultMeaning
table(required)holding (FC03/06/16), input (FC04, read-only), coil (FC01/05), discrete (FC02, read-only)
address(required)0-based protocol (PDU) address. Manual numbering: 4xxxx → holding xxxx − 1, 3xxxx → input, 1xxxx → discrete, 0xxxx → coil
typeuint16 (bool for coils/discretes)32-bit types use 2 registers, float64 uses 4. bool in a register means 0 = false, anything else = true
word_order / byte_orderbig / bigbig/big = ABCD (most significant register first). little/big = CDAB (common on PLCs). big/little = BADC. little/little = DCBA
scale, offset1, 0Engineering value = raw × scale + offset. Writes are rounded to the register's resolution and re-checked
unit, description""Shown to the agent
writablefalseOnly holding registers and coils can be writable
min, maxnoneEngineering-unit limits. Required for writable numeric points (unless enum is used)
enumnone{number: label} for integer points. Writes accept the label or the number

The server validates the map when it starts. Unknown fields (e.g. a misspelt maximum) and repeated keys (a second max, or a point defined twice) are errors rather than being silently ignored, so a typo can't remove a limit. Two writable points may not share a register (writing one would bypass the other's limits); read-only views of a writable register are fine. If the map is invalid, list_points shows the error and the device tools refuse to run. The server fails closed.

Add to your MCP client

Claude Code

claude mcp add oven -- uvx labmcp-modbus --address tcp://192.168.1.20:502 --option register_map=/home/me/maps/oven.yaml

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "controller": { "command": "uvx", "args": [ "labmcp-modbus", "--address", "serial:///dev/ttyUSB0?baudrate=9600&parity=N", "--option", "unit_id=1", "--option", "register_map=/home/me/maps/controller.yaml", "--option", "raw_writes=false" ] } } }

Useful flags:

  • --read-only allows reads only. apply_safe_state stays available.
  • --option raw_writes=false removes write_register, write_registers and write_coil, so the agent can only write what the map allows. This is recommended once your map is complete.

Tools

ToolKindDescription
apply_safe_state🛑 safetyPut the device into the safe state defined in the register map (e.g. heater output off, controller to standby), writing each step in order and reading it back. Every step is attempted even if an earlier one fails. Call it immediately if anything looks wrong. all_ok is true only if every step was written AND read back with the requested value; a step the device acknowledged but ignored (e.g. in local mode) is not ok.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
list_points👁 readDescribe the loaded register map: device, every named point (table, 0-based address, type, scaling, unit, writable, min/max, enum) and the safe-state steps. Works without a connection.
read_coils👁 readRead coils (FC01): single-bit outputs such as run/stop or relay states.
read_discrete_inputs👁 readRead discrete inputs (FC02): single-bit, read-only status such as alarms or limit switches.
read_points👁 readRead named points from the register map, decoded and scaled into engineering units (e.g. process_temperature = 25.1 °C). A point that cannot be read gets an error instead of failing the whole call.
read_registers👁 readRead raw holding or input registers (unsigned 16-bit), optionally decoded as int16, 32-bit or 64-bit values. For exploring a device; prefer read_points when a register map describes it.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
write_coil⚠️ hazardSwitch one raw coil (FC05). Coils often start or stop equipment (heaters, pumps, motors); mapped coils are refused here (use write_point).
write_point⚠️ hazardWrite a named point from the register map (setpoint, mode, output enable...). The value is checked against the point's writable flag, min/max or enum BEFORE sending, converted to raw registers, written, then read back. Changing setpoints and outputs acts on real equipment. If the write succeeds but the read-back fails, read_back_error says why.
write_register⚠️ hazardWrite one raw holding register (FC06). No scaling or limits are applied, so only use it for addresses the register map does not describe (mapped addresses are refused: use write_point). Returns a read-back if the register is readable.
write_registers⚠️ hazardWrite consecutive raw holding registers (FC16), e.g. both halves of a 32-bit value. No scaling or limits are applied; mapped addresses are refused (use write_point).

get_connection_info, get_command_log and reconnect are built into every La

Only the beginning is shown; read the rest in the repo

Ask PopNx