Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Description from the maker (original English)
MCP server for Rigol oscilloscopes (DS1000Z, MSO5000, DHO series): measurements and waveforms.
These three are never merged into one score: opinions, measurements and popularity are different things.
We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.
Pick the AI app you use, then copy the settings.
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITSYou need
Which app do you use?
Pick your app above. We remember it, so next time the button says “Install in …”.
Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json
{
"mcpServers": {
"labmcp-rigol-scope": {
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Run this in your terminal
claude mcp add labmcp-rigol-scope --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-rigol-scopeFill in the empty values before running it.
Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-rigol-scope": {
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.
Paste into .vscode/mcp.json in your project
{
"servers": {
"labmcp-rigol-scope": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.
This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.
Your choice stays on this device in a cookie; no account needed.
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envThese settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
We have not read this repo from GitHub yet
We have not read this repo from GitHub yet
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed –, and the latest version (0.1.2) reached the registry 42 days ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: Spec Driven Development, Remote Desktop Commander, SwarmMemo
Servers in the same category from other makers, sorted by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Talk with agent swarms: rooms, private messages and paid tasks for AI agents
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent read the setup, adjust channels, timebase and trigger, run single acquisitions, take the scope's own measurements, capture calibrated waveforms and grab screenshots on Rigol digital oscilloscopes over SCPI.
| Package | labmcp-rigol-scope |
| Instruments | DS1000Z / MSO1000Z (DS1054Z, DS1074Z, DS1104Z, MSO1104Z, "Plus" models), DS1000Z-E (DS1102Z-E, DS1202Z-E), MSO5000 (MSO5072 … MSO5354), DHO800 / DHO900 (DHO802, DHO804, DHO914, DHO924), DHO1000 / DHO4000 (DHO1072 … DHO4804) |
| Interfaces | USB (USB-TMC), LAN (VXI-11/LXI, raw socket) |
| Protocol | SCPI per Rigol's programming guides: MSO1000Z/DS1000Z PGA19109-1110, DS1000Z-E PGA27100-1110, MSO5000 PGA25104-1110, DHO800/DHO900, DHO1000/DHO4000 PGA34101-1110 |
| Status | 🧪 simulated: tested against a wire-level SCPI simulator (including binary waveform and screenshot blocks), not yet verified on hardware. Report a hardware test |
uvx labmcp-rigol-scope --simulate --check
uvx labmcp-rigol-scope --simulate --option sim_model=DHO804 --check # also DS1202Z-E, MSO5074, DHO1204 ...
The simulated scope has a 1 kHz, 0-3 V square wave on CH1 and a 2 kHz, 1 V sine on CH2 (CH3/CH4 grounded). It answers :WAVeform:DATA? and :DISPlay:DATA? with real IEEE 488.2 binary blocks, keeps an SCPI error queue, and its trigger only fires when the level is inside the signal, so you can try single with a bad trigger level.
pyvisa-py backend, which needs libusb on the system (brew install libusb, apt install libusb-1.0-0; on Windows use NI-VISA with ?backend=@ivi). Find the resource with python -m pyvisa info or uvx labmcp ports. uvx labmcp-rigol-scope --address USB0::0x1AB1::0x04CE::DS1ZA123456789::INSTR --check # USB-TMC
uvx labmcp-rigol-scope --address TCPIP0::192.168.1.50::INSTR --check # LAN (VXI-11) uvx labmcp-rigol-scope --address tcp://192.168.1.50:5555 --check # LAN raw socket
`--check` prints the `*IDN?` identity and the detected command family.
Claude Code
claude mcp add scope -- uvx labmcp-rigol-scope --address TCPIP0::192.168.1.50::INSTR
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "scope": { "command": "uvx", "args": ["labmcp-rigol-scope", "--address", "TCPIP0::192.168.1.50::INSTR"] } } }
Add --read-only to allow reading settings, measurements, waveforms and screenshots while blocking every tool that changes the scope setup. For other clients, generate the snippet with uvx labmcp config rigol-oscilloscope --address TCPIP0::192.168.1.50::INSTR --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
autoscale | 🎛 control | Run the scope's automatic setup (AUTO key): it picks vertical scales, timebase and trigger for the connected signals. This overwrites the user's current setup - only use it when asked. Needs signals of roughly >20 mVpp and >40 Hz. |
capture_waveform | 👁 read | Capture a channel's waveform, scaled to volts and seconds with the scope's waveform preamble, and return statistics plus a downsampled trace; optionally save all points to CSV. |
force_trigger | 🎛 control | Force one trigger (FORCE key). Only has an effect in NORMal or SINGle sweep while waiting. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Identify the oscilloscope (model, serial, firmware), the command family used for it, the number of analog channels, and the current sample rate and memory depth. |
get_settings | 👁 read | Read the current vertical settings of every channel (on/off, V/div, offset, coupling, probe ratio, bandwidth limit), the timebase, the trigger (type, sweep, status, edge source/level/slope) and the acquisition sample rate / memory depth. |
measure | 👁 read | Read the scope's automatic measurements for one channel: voltages (Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, overshoot, preshoot) and timing (period, frequency, rise/fall time, +/- width, +/- duty). Values the scope cannot determine are null. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
run | 🎛 control | Start continuous acquisition (RUN). |
screenshot | 👁 read | Save a screenshot of the oscilloscope display (PNG; BMP on the MSO5000) and return its path. For PNG screenshots the image is also returned so the model can look at the screen. |
set_channel | 🎛 control | Change a channel's vertical settings; unspecified settings are left alone. The probe ratio is applied first because it changes the valid scale range. Returns the settings the scope actually applied (the scale snaps to 1-2-5 steps). Rejected values are reported from the scope's error queue. |
set_timebase | 🎛 control | Set the main timebase scale and/or offset. Returns the applied values. |
set_trigger | 🎛 control | Configure an edge trigger (source, level, slope) and the sweep mode. Sets the trigger type to EDGE. The level must lie within the source channel's screen range. |
single | 🎛 control | Arm a single acquisition (SINGLE key): the scope triggers once, then stops. With wait_s > 0 it waits until the acquisition is complete (status STOP). If the trigger condition is never met the status stays WAIT - check the trigger level/source or use force_trigger. |
stop | 🎛 control | Stop acquisition (STOP) and freeze the current waveforms, e.g. before reading deep memory. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log shows every SCPI command sent.
| Limit | Default | Meaning |
|---|---|---|
max_memory_points | 1 200 000 points | Most points read from acquisition memory in one capture (bounds transfer time) |
Override at launch, e.g. --limit max_memory_points=24000000. An oscilloscope does not source energy, so there are no hazard tools; this server does not control the built-in waveform generator some models have.
:TRIGger:EDGE:LEVel, :MEASure:ITEM? VPP,CHANnel1, :WAVeform:PREamble?). The differences are taken from each guide: autoscale is :AUToscale (DS1000Z, MSO5000) or :AUToset (DHO); screenshots are :DISPlay:DATA? ON,OFF,PNG (DS1000Z), :DISPlay:DATA? PNG (DHO) or :DISPlay:DATA? → BMP (MSO5000); screen captures return 1200 points (DS1000Z, 12 divisions) or 1000 (MSO5000/DHO, 10 divisions). The family is detected from *IDN?; unknown Rigol models are refused unless you force --option profile=DS1000Z|MSO5000|DHO.:WAVeform:PREamble? and BYTE format: volts = (byte − YORigin − YREFerence) × YINCrement. WORD format is not used because the DHO guides do not document its byte order. For the 12-bit DHO scopes this means 8-bit screen/memory data.mode="memory") follows the documented RAW procedure: stop the scope, then read in batches of 250 000 points with :WAVeform:STARt/STOP (the DS1000Z maximum for BYTE). The MSO5000 and DHO guides document batched reads but not a maximum; the server checks every batch length and fails clearly if a batch comes back short. *Not yet verified on MSO5000/DHO hardware.*clipped_fraction counts points at the ADC limits (codes 0/255) in both modes. The returned trace keeps each block's minimum and maximum sample, so narrow glitches survive downsampling. save_path (CSV) and the screenshot save_path (.png, .bmp on the MSO5000) must be new files: they are checked before anything is read, and existing files are never overwritten.null when the scope answers 9.9E37 (cannot measure). Duty cycle and overshoot are reported exactly as the scope returns them (the DS1000Z guide defines duty as a ratio).:SYSTem:ERRor? afterwards, so an out-of-range scale, offset or trigger level is reported instead of silently ignored. The scale snaps to 1-2-5 steps unless fine adjustment (VERNier) is on.TCPIP0:: ::INSTR). Rigol scopes also accept raw SCPI on TCP port 5555 (tcp:// :5555); that port is widely used but not stated in these guides.libusb for pyvisa-py; pyusb is installed with this package.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |