Prototype · Preview: every server in the official registry, synced every 30 minutes. Reviews and accounts come in a later step.
PopNx MCPMCP servers for people who use AI · explained in plain words

Sartorius Balance

by K-Dense-AIversion 0.1.2i★ –iRuns on your computer
Registry nameio.github.K-Dense-AI/labmcp-sartorius

Install

Overview

Description from the maker (original English)

MCP server for Sartorius laboratory balances (SBI protocol).

PopNx MCP’s three pillars

These three are never merged into one score: opinions, measurements and popularity are different things.

What you can do with it

We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.

  • Connection: Runs on your computer
  • Transport: stdio
  • Category: Other

Install

Pick the AI app you use, then copy the settings.

Before you install

  • Basic checks: 1 of 1 passed
  • Runs on your computer with your user’s permissions (files, network, apps).
  • You fill in yourself: LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS

You need

  • PyPIPython’s uv installed (for the uvx command)

Which app do you use?

Pick your app above. We remember it, so next time the button says “Install in …”.

Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json

{
  "mcpServers": {
    "labmcp-sartorius": {
      "command": "uvx",
      "args": [
        "labmcp-sartorius"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Run this in your terminal

claude mcp add labmcp-sartorius --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-sartorius

Fill in the empty values before running it.

Open in Cursor

Or copy the settings yourself

Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json

{
  "mcpServers": {
    "labmcp-sartorius": {
      "command": "uvx",
      "args": [
        "labmcp-sartorius"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

Open in VS Code

Or copy the settings yourself

Paste into .vscode/mcp.json in your project

{
  "servers": {
    "labmcp-sartorius": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-sartorius"
      ],
      "env": {
        "LABMCP_ADDRESS": "your-value",
        "LABMCP_SIMULATE": "your-value",
        "LABMCP_READ_ONLY": "your-value",
        "LABMCP_LIMITS": "your-value"
      }
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.

Your choice stays on this device in a cookie; no account needed.

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 9, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • … Not checked yet

    Still maintained

    We have not read this repo from GitHub yet

  • … Not checked yet

    Has a licence

    We have not read this repo from GitHub yet

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Compared with others in Otheri

  • More stars than 0% of the other 18726 servers in this category
  • Published to the registry more recently than 51% of the other 18726 servers in this category
  • Basic checks equal to or better than 100% of the other 18726 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Sartorius Balance safe?

It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed –, and the latest version (0.1.2) reached the registry 43 days ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: Spec Driven Development, Remote Desktop Commander, SwarmMemo

Alternatives

Servers in the same category from other makers, sorted by stars.

Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

Spec Driven Development

MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.

by formulahendryEarly↓ 66/wk★ 440Updated 14 months ago

Runs on your computer

Remote Desktop Commander

Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.

by desktop-commanderGrowing★ 211Updated 4 days ago

Runs in the cloud✓ desktopcommander.app

SwarmMemo

Talk with agent swarms: rooms, private messages and paid tasks for AI agents

by Hugo0EarlyUpdated today

Runs in the cloud✓ swarmmemo.com

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Sartorius Balance — MCP Server

Let an AI agent weigh samples, tare containers, log drift and evaporation, and run internal adjustments on Sartorius laboratory balances through the documented SBI (Sartorius Balance Interface) ASCII protocol.

Packagelabmcp-sartorius
InstrumentsCubis MSE, Cubis II MCA, Secura, Quintix, Practum, Entris II; older CP/CPA-series balances with --option legacy=true. Other SBI balances are likely to work
InterfacesRS-232, USB (virtual COM port, "PC-SBI"), Ethernet (Cubis II "serial transmission via Ethernet", or any serial-to-Ethernet adapter)
ProtocolSBI: Entris II interface description (technical note 10/2020), Secura/Quintix/Practum user manual §10.3 (WSE6004), Cubis MSE operating instructions (WMS6004), Cubis MCA operating instructions (WMC6028), SBI interface description (98647-000-53)
Status🧪 simulated: tested against a wire-level SBI simulator, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-sartorius --simulate --check

Connect your balance

  1. Balance setup: set the interface you use (RS232, USB-B / "PC-SBI", or Ethernet) to the SBI protocol, and set SBI data output to manual, without stability with automatic output off (factory settings on Cubis II and Entris II). With auto print on, ESC P toggles the automatic output instead of sending one reading. Either line format works (16 characters, or 22 with ID code).
  2. Serial settings: factory settings are 9600 baud, 8 data bits, odd parity, 1 stop bit, hardware handshake (Cubis II/MSE, Secura/Quintix/Practum, Entris II). The server uses these but does not enforce RTS/CTS (it keeps RTS asserted, which lets the balance transmit; USB virtual COM ports often never assert CTS). Add ?rtscts=true to enforce it, or e.g. ?bytesize=7&parity=E if your balance is set differently.
  3. Find the port: uvx labmcp ports
  4. Test the connection:
   uvx labmcp-sartorius --address /dev/ttyUSB0 --check                 # Linux

uvx labmcp-sartorius --address /dev/tty.usbmodem14201 --check # macOS uvx labmcp-sartorius --address COM4 --check # Windows uvx labmcp-sartorius --address tcp://192.168.1.61:49155 --check # Cubis II via Ethernet (port as configured)

   `--check` prints the model, serial number and software version (`ESC x1_`, `x2_`, `x3_`) when the balance supports them.

Add to your MCP client

Claude Code

claude mcp add balance -- uvx labmcp-sartorius --address /dev/ttyUSB0

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "balance": { "command": "uvx", "args": ["labmcp-sartorius", "--address", "/dev/ttyUSB0"] } } }

Add --read-only to allow weighing but block taring, zeroing and adjustment. For other clients: uvx labmcp config sartorius-balance --address /dev/ttyUSB0 --client vscode.

Tools

ToolKindDescription
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
lock_keypad🎛 controlBlock or unblock the balance keys, e.g. so nobody tares by accident during a long logging run.
log_weight_series👁 readRecord a series of immediate (unfiltered) readings to monitor drift, evaporation, moisture uptake or stabilisation. Returns every reading plus summary statistics.
read_weight👁 readRead the current net weight from the balance (ESC P). With stable=True the server polls until the balance reports a stable value; if it cannot settle (draughts, vibration, evaporation) you get an error; retry, or use stable=false for the current value.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
run_internal_adjustment🎛 controlAdjust (calibrate) the balance with its built-in weight (ESC Z; isoCAL models only). The pan must be empty and the balance undisturbed. SBI sends no completion message, so the server watches for the adjustment status and waits until the balance weighs again; check observed_adjustment and the balance display or GLP printout for the result.
set_ambient_conditions🎛 controlAdapt the balance's filter to the ambient conditions (ESC K/L/M/N). Use 'unstable' or 'very_unstable' for draughty or vibrating benches (slower but steadier readings).
tare🎛 controlTare the balance (ESC U, or ESC T on legacy balances): the current load (e.g. an empty container) becomes the tare. Then waits for a stable reading and checks that it is ~0; returns that reading.
zero🎛 controlZero the balance (ESC V). Only works with the pan (nearly) empty, within the balance's zero-setting range; clears the tare. Confirms by reading ~0 afterwards.

Safety limits

LimitDefaultMeaning
max_series_duration_s600 sLongest weight-logging series an agent may start

Override at launch: --limit max_series_duration_s=3600. Whatever the limit says, a single series is capped at one hour (the tool's time limit). No tool of this server moves anything or heats, so there are no hazard tools.

Example prompts

  • "Tare the balance, then tell me the weight once it's stable after I add the sample."
  • "Log the weight every 10 s for 5 minutes and tell me the evaporation rate in mg/min."
  • "Weigh out ~250 mg: tell me how much more to add, reading every few seconds, until I'm within ±2 mg."
  • "The bench is vibrating today; switch the balance filter to unstable conditions and lock the keypad."
  • "Run an internal adjustment before we start the calibration curve and tell me whether it ran."

Notes

  • Stability comes from the unit symbol. SBI has no explicit stability flag: the balance only sends the unit symbol (positions 12–14) when the reading is stable ("If the weighing system has not stabilized, no unit symbol is output", interface description 98647-000-53; the newer manuals list those positions as "unit symbol or space"). read_weight(stable=true) therefore polls ESC P until a reading with a unit arrives. Unstable readings report the last unit seen.
  • Line formats. The parser follows the documented fixed-width layouts: 16 characters (sign, value in positions 2–10, unit in 12–14, CR LF) and 22 characters (6-character ID code such as N, G#, T, Stat, then the same 16). It also accepts the Cubis II "one line with full length" format, a decimal comma, and a G#/T/N weighing block (the N line is reported). High, Low, Err ###, APP.ERR, DIS.ERR and PRT.ERR are reported as clear errors.
  • No acknowledgements. SBI control commands (ESC U tare, ESC V zero, ESC Z adjust, ESC K–N filter, ESC O/R keys) produce no reply, so a balance that does not support one silently ignores it. tare and zero therefore wait for a stable reading and check it is ~0, and report an error otherwise.
  • Zero vs tare. ESC V only zeroes within the balance's zero-setting range (nearly empty pan); ESC U tares any load. Older balances (CP/CPA, LE, ...) only have ESC T (the tare key): start the server with --option legacy=true.
  • Internal adjustment (unverified). ESC Z starts isoCAL on balances with a built-in weight. SBI sends no completion or result message; the server watches for the Cal. status (or a balance too busy to answer) and waits for a stable weight again, and reports observed_adjustment=false if it never sees one. Confirm the result on the display or GLP printout. The exact status output during adjustment could not be verified in the manuals.
  • Identity replies (unverified format). ESC x1_/x2_/x3_ print the model, serial number and software version; their exact layout is not documented, so the text is passed through as sent.
  • The command log shows SBI traffic as hex (1b 50 0d 0a = ESC P CR LF) because of the ESC character.
  • Not implemented: draft-shield and ionizer commands (Cubis MSE only), external adjustment (ESC W, needs a reference weight), ESC S restart and the function-key commands.

Hardware verification

ModelFirmwareInterfaceVerified byDate
*none yet: be the first*
Ask PopNx