timesfm
TimesFM (Time Series Foundation Model) is a pretrained time-series foundation model developed by Google Research for time-series forecasting.
MCP server for Stanford Research Systems lock-in amplifiers (SR810/SR830, SR860/SR865A).
Skills that teach the AI this kind of work; they work alongside this one
TimesFM (Time Series Foundation Model) is a pretrained time-series foundation model developed by Google Research for time-series forecasting.
Open-source intelligence for the global theater. Track everything from the corporate/private jets of the wealthy, and spy satellites, to seismic events in one unified interface. Hook an AI agent up to have it parse through data and find previously unseen correlations. The knowledge is available to…
scrape data from Google Maps. Extracts data such as the name, address, phone number, website URL, rating, reviews number, latitude and longitude, reviews,email and more for each place
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 0/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 7/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 7/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install SRS Lock-in Amplifier. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-srs-lockin.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server SRS Lock-in Amplifier for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-srs-lockin": { "command": "uvx", "args": [ "labmcp-srs-lockin" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the SRS Lock-in Amplifier tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-srs-lockin": {
"command": "uvx",
"args": [
"labmcp-srs-lockin"
]
}
}
}Use SRS Lock-in Amplifier and tell me what you can do for me, then show me one thing✓ If Claude says it is using SRS Lock-in Amplifier or shows a SRS Lock-in Amplifier tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect SRS Lock-in Amplifier yet
SRS Lock-in Amplifier runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect SRS Lock-in Amplifier
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server SRS Lock-in Amplifier for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-srs-lockin -- uvx labmcp-srs-lockin 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the SRS Lock-in Amplifier tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-srs-lockin -- uvx labmcp-srs-lockinYou should see SRS Lock-in Amplifier listed as connected
Use SRS Lock-in Amplifier and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using SRS Lock-in Amplifier or shows a SRS Lock-in Amplifier tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server SRS Lock-in Amplifier for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-srs-lockin": { "command": "uvx", "args": [ "labmcp-srs-lockin" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the SRS Lock-in Amplifier tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use SRS Lock-in Amplifier and tell me what you can do for me, then show me one thing✓ If Cursor says it is using SRS Lock-in Amplifier or shows a SRS Lock-in Amplifier tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server SRS Lock-in Amplifier for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-srs-lockin": { "type": "stdio", "command": "uvx", "args": [ "labmcp-srs-lockin" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the SRS Lock-in Amplifier tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use SRS Lock-in Amplifier and tell me what you can do for me, then show me one thing✓ If VS Code says it is using SRS Lock-in Amplifier or shows a SRS Lock-in Amplifier tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-srs-lockin -- uvx labmcp-srs-lockinClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-srs-lockin": {
"command": "uvx",
"args": [
"labmcp-srs-lockin"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-srs-lockin": {
"command": "uvx",
"args": [
"labmcp-srs-lockin"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-srs-lockin": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-srs-lockin"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-srs-lockinBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
No entries on OSV.dev for labmcp-srs-lockin@0.1.3
Checks only this package version, not every dependency · checked Nov 16, 2026
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-srs-lockin)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.3) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: OpenSEO, Exa, Microsoft Learn MCP, Docs, COTAL actions (cotal.ai)
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Keyword research, site audits, rank tracking and AI visibility for your AI agent.
Connect AI agents to Exa for web search, content fetching, and multi-step research.
Official Microsoft Learn MCP Server – real-time, trusted docs & code samples for AI and LLMs.
Search and read Empryo's documentation. Read-only, no auth, no local access.
cotal.ai actions: product overview, site search, build log, feedback, Cloud waitlist, updates, calls
| This one SRS Lock-in Amplifier | OpenSEO | Exa | Microsoft Learn MCP | Docs | COTAL actions (cotal.ai) | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install |
| Needs a key | No | No | No | No | No | No |
| Add with + in Claude | No | Yes | Yes | Yes | No | No |
| Basic checks | 3/3 | 5/5 | 2/4 | 4/4 | 4/4 | 4/4 |
| License | Apache-2.0 | MIT | MIT | CC-BY-4.0 | NOASSERTION | Apache-2.0 |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent read X/Y/R/θ, set the reference frequency, harmonic and phase, drive level, sensitivity and time constant, run auto phase/gain, and record bounded frequency sweeps on Stanford Research Systems DSP lock-in amplifiers, both the classic SR810/SR830 and the current SR860/SR865A.
| Package | labmcp-srs-lockin |
| Instruments | SR830, SR810 (SR8x0 command set); SR860, SR865A (SR86x command set) |
| Interfaces | GPIB (VISA), RS-232; SR86x also USB (USBTMC) and Ethernet (VXI-11) |
| Protocol | SRS ASCII remote commands, IEEE-488.2 style (SR830 manual ch. 5, SR810 manual, SR860 manual ch. 4, SR865A manual) |
| Status | 🧪 simulated: tested against a wire-level simulator of both command sets, not yet verified on hardware. Report a hardware test |
uvx labmcp-srs-lockin --simulate --check # SR830 simulator
uvx labmcp-srs-lockin --simulate --option model=sr860 --check # SR860 simulator
The simulated sample is a resonator (10 kHz, Q = 50) driven by the sine output, so a frequency_sweep from 9 to 11 kHz shows a resonance peak.
The model is detected from *IDN? (override with --option model=sr830|sr810|sr860|sr865a).
labmcp[visa] (included) and a VISA backend (pyvisa-py works with most USB-GPIB adapters; NI-VISA with ?backend=@ivi).OUTX; the server sends OUTX 0 automatically on serial connections and OUTX 1 on GPIB. The SR830 ends RS-232 replies with CR. For an SR86x on RS-232, pass --option model=sr860 (replies end with LF) or set the SR86x transmit terminator to CR.TCPIP0:: ::inst0::INSTR; enable VXI-11 and add your PC to the trusted IP range in the system menu). uvx labmcp-srs-lockin --address GPIB0::8::INSTR --check
uvx labmcp-srs-lockin --address /dev/ttyUSB0 --check # SR830 RS-232 uvx labmcp-srs-lockin --address "serial://COM3?baudrate=19200" --check # non-default baud uvx labmcp-srs-lockin --address TCPIP0::192.168.1.20::inst0::INSTR --check # SR86x LAN
Use `--option interface=gpib` if you reach an SR830's GPIB port through a raw TCP adapter.
Claude Code
claude mcp add lockin -- uvx labmcp-srs-lockin --address GPIB0::8::INSTR
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "lockin": { "command": "uvx", "args": ["labmcp-srs-lockin", "--address", "GPIB0::8::INSTR"] } } }
Add --read-only to allow reading outputs and settings but block every setting change and the sine-output drive. For other clients, generate the snippet with uvx labmcp config srs-lockin --address GPIB0::8::INSTR --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
auto_gain | 🎛 control | Pick the sensitivity automatically for the present signal (SR830 AGAN / SR86x ASCL). On the SR830 AGAN does nothing when the time constant is longer than 1 s. |
auto_phase | 🎛 control | Run Auto Phase (APHS): shift the reference phase so that Y ≈ 0 and X ≈ R. The outputs then need several time constants to settle. Does nothing if the phase is unstable. |
auto_range | 🎛 control | Optimise the input stage for the present signal: SR830 Auto Reserve (ARSV) or SR86x Auto Range of the voltage input range (ARNG). |
frequency_sweep | ⚠️ hazard | Step the internal reference (and SINE OUT drive) from start_hz to stop_hz, waiting for the output filter to settle at each point, and record X/Y/R/θ vs frequency - e.g. a resonance or transfer-function measurement. The drive amplitude stays at its present value. Needs the internal reference. The estimated duration must be within max_sweep_duration_s; set_amplitude_minimum stops a running sweep. save_path must be a new .csv file. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_settings | 👁 read | Report the reference (source, frequency, harmonic, phase), sine output, sensitivity, time constant/slope (with the 99 % settling time), and input configuration. |
read_outputs | 👁 read | Read X, Y, R and θ as one coherent snapshot (SNAP?), with the reference frequency, sensitivity, fraction of full scale and any overloads latched since the last reading. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_amplitude | ⚠️ hazard | Set the SINE OUT amplitude (V rms), which drives the sample or excitation circuit. Refused above the max_amplitude_v safety limit. Tell the user the new drive level first. |
set_amplitude_minimum | 🛑 safety | Turn the sine output down to the instrument minimum (the lock-in's closest thing to 'output off') and stop any running frequency sweep. SR810/SR830: 4 mV rms (it cannot go to zero - disconnect the cable if the sample must see no drive). SR86x: 1 nV rms and DC level 0 V. |
set_input | 🎛 control | Configure the signal input: A / A-B / current, AC or DC coupling, shield float/ground and (SR86x) the voltage input range. Use DC coupling below ~160 mHz. Omitted parameters are left unchanged. |
set_reference | 🎛 control | Set the reference: source (internal/external), internal frequency, detection harmonic and phase shift. Omitted parameters are left unchanged. Changing the frequency also changes the frequency of the SINE OUT drive (at the current amplitude). |
set_sensitivity | 🎛 control | Set the sensitivity (full-scale range). The smallest available range that is at least full_scale is chosen, so a signal of that size does not overload. On SR810/SR830 the dynamic reserve can be set at the same time. |
set_time_constant | 🎛 control | Set the output filter time constant (nearest available value), and optionally the filter slope and synchronous filter. The SR830 may raise a too-short time constant to its minimum for the current slope/reserve; the returned settings show the value actually used. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
| Limit | Default | Meaning |
|---|---|---|
max_amplitude_v | 1.0 V | Largest sine-output amplitude (V rms) set_amplitude may set; a sweep also refuses to run if the present amplitude is above it |
max_sweep_duration_s | 600 s | Longest estimated frequency sweep (points × settle time) an agent may start |
Override at launch: --limit max_amplitude_v=0.1 --limit max_sweep_duration_s=1800.
set_amplitude checks max_amplitude_v; set_amplitude_minimum is the closest thing to "output off": the SR810/SR830 cannot go below 4 mV rms, so disconnect the cable if the sample must see no drive. On the SR86x it sets 1 nV rms and a 0 V DC level (SOFF). The SR830 powers up and resets (*RST) to 1.000 V rms.*ESR?; if the lock-in flags an execution error (parameter out of range, e.g. FREQ in external-reference mode) or an illegal command, the tool reports it instead of silently continuing.set_sensitivity picks the smallest range that is at least the requested full scale (never a smaller one, which would overload). set_time_constant picks the nearest available value; the SR830 may raise it to the minimum allowed for the slope/reserve, and the returned settings show the value actually used.read_outputs returns unit = V for voltage inputs and A for the current input (1 V ↔ 1 µA sensitivity mapping from the manuals). The SR830 manual (SR530-compatibility QX/QY commands, ch. 5) states that outputs are returned in amps when the current input is selected; the SR86x manual does not say explicitly — please report what your instrument returns.overloads comes from LIAS?, whose bits are latched since the last read; the first reading after a transient may show an overload that has already cleared.frequency_sweep waits the manual's 99 % settling time at each point (5/7/9/10 time constants for 6/12/18/24 dB/oct) unless settle_time_constants is given, and restores the starting frequency afterwards. Calling set_amplitude_minimum stops a running sweep at the next point (also one that is still reading its settings). One sweep can take at most 3640 s (the tool's timeout minus a margin) whatever max_sweep_duration_s is: longer estimates are refused, and a sweep running slower than estimated stops early and returns the points measured so far (completed: false). save_path must end in .csv and must not exist yet (an existing file is never overwritten); it is checked before the sweep starts.set_amplitude_minimum tries both the amplitude and (SR86x) the DC level even if one of them fails, then reports every failure.auto_gain maps to AGAN (SR830) or ASCL (SR86x); auto_range maps to ARSV (SR830 auto reserve) or ARNG (SR86x auto input range). SR830 AGAN does nothing when the time constant is above 1 s.--option model=... lets you try a compatible model at your own risk.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |