Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Description from the maker (original English)
MCP server adapter for Thermo Fisher Orbitrap mass spectrometers via the licensed Instrument API.
These three are never merged into one score: opinions, measurements and popularity are different things.
We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.
Pick the AI app you use, then copy the settings.
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITSYou need
Which app do you use?
Pick your app above. We remember it, so next time the button says “Install in …”.
Open Claude Desktop → Settings → Developer → Edit Config, and paste this into claude_desktop_config.json
{
"mcpServers": {
"labmcp-thermo-iapi": {
"command": "uvx",
"args": [
"labmcp-thermo-iapi"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Run this in your terminal
claude mcp add labmcp-thermo-iapi --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-thermo-iapiFill in the empty values before running it.
Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-thermo-iapi": {
"command": "uvx",
"args": [
"labmcp-thermo-iapi"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.
Paste into .vscode/mcp.json in your project
{
"servers": {
"labmcp-thermo-iapi": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-thermo-iapi"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.
This one runs on your computer, and ChatGPT can only connect to servers on the internet. Pick another app.
Your choice stays on this device in a cookie; no account needed.
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envThese settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
We have not read this repo from GitHub yet
We have not read this repo from GitHub yet
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 1 of 1 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed –, and the latest version (0.1.1) reached the registry 42 days ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: Spec Driven Development, Remote Desktop Commander, Thalovant MCP
Servers in the same category from other makers, sorted by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Connect MCP clients to Thalovant control-plane and hub runtime APIs over stdio or Streamable HTTP.
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent watch and steer a Thermo Fisher Orbitrap mass spectrometer in real time: check the instrument mode and vacuum, read the scans streaming off the instrument (filtered by MS order, with the most intense centroids), place validated custom scans and pick up their results, set a repeating scan, and start, pause or stop acquisitions to a raw file. It does this through Thermo's own Instrument API (IAPI).
[!IMPORTANT]
This is an adapter. It contains no Thermo software. The IAPI is a Windows .NET API. To use it you need a signed IAPI software licence agreement with Thermo Fisher Scientific, with the licence applied to your instrument (legal requirements, licence FAQ, how to obtain a licence). This package never bundles or downloads the IAPI assemblies: you point it at the ones you obtained. It has never been tested on real hardware. Everything below was developed against the official IAPI interface definitions and examples and a simulator.
| Package | labmcp-thermo-iapi (install the [windows] extra on the instrument PC for pythonnet) |
| Instruments | Orbitrap Tribrid (Fusion, Fusion Lumos, Eclipse, Ascend), Orbitrap Exploris 240/480, Q Exactive family. Not the Orbitrap Astral: Thermo states the Astral line does not support IAPI (as of fall 2025). Not the Exploris 120, which Thermo's examples say doesn't support the API. |
| Interfaces | .NET API on the Windows instrument PC (through pythonnet) |
| Protocol | Thermo Fisher Instrument API (IAPI): interface definitions in lib/*.xml, examples in examples/ |
| Status | 🧪 simulated: tested against a simulated Orbitrap (FakeOrbitrap), not yet verified on hardware. Report a hardware test |
uvx labmcp-thermo-iapi --simulate --check
The simulator is an Orbitrap Exploris 480 by default (--option sim_model=eclipse or qexactive-hf for the others). It runs a synthetic tryptic digest: MS1 survey scans in On mode, a data-dependent top-10 method during an acquisition, custom and repeating scans that come back with their access id, realistic transient and injection times, and a status log with vacuum readings every ~5 s.
On the Windows instrument PC, with Tune installed and your IAPI licence applied:
API-2.0.dll, Spectrum-1.0.dll, Thermo.TNG.Factory.dll and Fusion.API-2.0.dll for Tune 4.3 or Fusion.API-1.0.dll for Tune 4.2 and earlier). Put them in a folder, e.g. C:\IAPI. pip install "labmcp-thermo-iapi[windows]"
labmcp-thermo-iapi --option instrument=tribrid --option assembly_dir=C:\IAPI --check # Fusion/Lumos/Eclipse/Ascend
labmcp-thermo-iapi --option instrument=exploris --option assembly_dir=C:\IAPI --check # Exploris 240/480 labmcp-thermo-iapi --option instrument=exactive --option assembly_dir=C:\IAPI --check # Q Exactive family
| Family | How the server connects (from the IAPI repository) | Assemblies expected in assembly_dir |
|---|---|---|
tribrid | Factory .Create(), StartOnlineAccess(), Get(1) | API-2.0.dll, Spectrum-1.0.dll, Thermo.TNG.Factory.dll, Fusion.API-2.0.dll or Fusion.API-1.0.dll |
exploris | HKLM\SOFTWARE\Thermo Exploris → DataSystem.xml (ApiFileName, ApiClassName) | Thermo.API.NetStd-1.0.dll, Thermo.API.Exploris.NetStd-1.0.dll, Thermo.API.Spectrum.NetStd-1.0.dll (4.3+) or the Thermo.API-2.0 / Thermo.API.Exploris-1.0 / Thermo.API.Spectrum-1.x set |
exactive | HKLM\SOFTWARE\Finnigan\Xcalibur\Devices\Thermo Exactive (ApiFileName_Clr2_32_V1, ApiClassName_Clr2_32_V1) | API-2.0.dll (or 1.x), Spectrum-1.0.dll, ESAPI-1.1.dll (or 1.0) |
The server gives a specific message if it is not running on Windows, pythonnet is missing, the folder or an assembly is missing, the IAPI service does not connect (Tune not running), or IAPI refuses a command for lack of a licence.
Other options: readbacks=Name1;Name2 (instrument values to show in get_instrument_status; the tool lists the names your instrument exposes), exclusive_scans=true (exclusive rather than cooperative IScans access), runtime=coreclr, connect_timeout_s, buffer_size (scans kept in memory, default 500).
claude mcp add orbitrap -- labmcp-thermo-iapi --option instrument=tribrid --option assembly_dir=C:\IAPI
{
"mcpServers": { "orbitrap": { "command": "labmcp-thermo-iapi", "args": ["--option", "instrument=exploris", "--option", "assembly_dir=C:\\IAPI"] } } }
Add --read-only to let the agent watch scans and status but not place scans or start acquisitions. The stop and cancel tools stay available. To reach the server from another computer, run it with --transport http --host 0.0.0.0 --port 8000 on the instrument PC and protect that port.
| Tool | Kind | Description |
|---|---|---|
cancel_custom_scans | 🛑 safety | Cancel any pending custom scan and its processing delay (IAPI CancelCustomScan). |
cancel_repeating_scan | 🛑 safety | Cancel the repeating scan set with set_repeating_scan (IAPI CancelRepetition). |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_instrument_status | 👁 read | Report the instrument model, IAPI service/instrument connection, system mode and state (On/Standby/Off; Running/ReadyToDownload/...), whether an acquisition can be paused or resumed, the IAPI licence where the API exposes it, requested readbacks, the latest scan status log (vacuum, source) and how many scans have arrived. |
get_possible_scan_parameters | 👁 read | List the scan parameters this instrument accepts for custom and repeating scans (IScans.PossibleParameters): name, allowed range or choices, default and help. The set depends on the model, licence and Tune version. |
get_recent_scans | 👁 read | Return the most recent scans received from the instrument (oldest first), optionally only one MS order or one custom scan's access id: scan number, MS order, precursor m/z, AGC target, injection time and the most intense centroids. Scans only arrive in On mode. |
pause_acquisition | 🛑 safety | Pause the running acquisition (IAPI Pause). Fails if the instrument reports it cannot pause. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
resume_acquisition | ⚠️ hazard | Resume a paused acquisition (IAPI Resume). Sample consumption continues. |
set_repeating_scan | ⚠️ hazard | Define or replace the scan the instrument repeats when no method or custom scan is running (IAPI CreateRepeatingScan/SetRepetitionScan). Values are validated like submit_custom_scan. Cancel with cancel_repeating_scan. |
start_acquisition | ⚠️ hazard | Start an acquisition with the instrument's current settings (IAPI StartAcquisition), recording to a raw file. This consumes sample. The instrument must be On; an acquisition must not already be running. Stop it with stop_acquisition. scan_count and until_stopped acquisitions are cancelled automatically after max_acquisition_duration_s. |
stop_acquisition | 🛑 safety | Stop the running acquisition (IAPI CancelAcquisition), by default also cancelling custom and repeating scans, and optionally switch the instrument to Standby (switch back to On in Tune). Every step is attempted even if an earlier one fails; failures are reported. |
submit_custom_scan | ⚠️ hazard | Place one custom scan to run next (IAPI CreateCustomScan/SetCustomScan); unset values fall back to the instrument's defaults. Every value is checked against PossibleParameters and the safety limits, and calls are rate-limited, before anything is sent. Fetch the result with wait_for_scan(access_id=running_number). |
wait_for_scan | 👁 read | Wait for the next scan that arrives after this call (optionally of one MS order, or the result of a custom scan by its access id) and return it. For a custom scan placed with submit_custom_scan, a result that arrived since it was placed is returned at once. Returns found=false after timeout_s if nothing matching arrived (e.g. the instrument is in Standby). |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. Every IAPI control call (with the exact scan values sent) is recorded in the command log.
| Limit | Default | Meaning |
|---|---|---|
max_custom_scans_per_minute | 60 scans/min | Custom scans an agent may place in any 60 s window (server-side rate limit; reconnect does not reset it) |
max_injection_time_ms | 1000 ms | Largest maximum injection time (MaxIT) in a custom or repeating scan (every element of a multi-valued MaxIT) |
max_acquisition_duration_s | 7200 s | Longest acquisition an agent may start: a duration above it is refused, and scan_count / until_stopped acquisitions are cancelled automatically when it runs out (wall-clock, pauses included) |
Override at launch: --limit max_custom_scans_per_minute=600.
On top of these limits, every custom and repeating scan value is checked against the instrument's own IScans.PossibleParameters before anything is sent: the parameter name must exist, numbers must lie inside the instrument's range (for example the m/z range for FirstMass/LastMass), and choice parameters such as OrbitrapResolution must be one of the allowed values. IAPI itself silently ignores illegal values, which is why the server checks first, and why accepted values are sent in the instrument's own spelling (hcd goes out as HCD, 2.0 for an integer parameter as 2).
stop_acquisition attempts every step (cancel the acquisition, the custom scans, the repeating scan, Standby) even if one fails, and reports what failed.
stop_acquisition(standby=true) switches to Standby. This server has no tool to switch back to On (do that in Tune).IScanDefinition.Values. running_number comes back as the scan's `access_idOnly the beginning is shown; read the rest in the repo