Prototype · Preview: every server in the official registry, synced every 30 minutes. Reviews and accounts come in a later step.
PopNx MCPMCP servers for people who use AI · explained in plain words

uniwire

by uniwire-devversion 0.1.8i★ –iRuns in the cloud
Registry nameio.github.uniwire-dev/uniwire

Install

Overview

Description from the maker (original English)

Electrical single-line and multi-line diagrams: build, check (NF C 15-100, IEC 60364), draw, PDF.

PopNx MCP’s three pillars

These three are never merged into one score: opinions, measurements and popularity are different things.

What you can do with it

We have not written a plain-language summary for this one yet. Below are the facts we read from the registry.

  • Connection: Runs in the cloud
  • Transport: Streamable HTTP
  • Category: Design, images & audio

Install

Pick the AI app you use, then copy the settings.

Before you install

You need

Which app do you use?

Pick your app above. We remember it, so next time the button says “Install in …”.

Works in Claude on the web, desktop and mobile:

  1. Open Settings → Connectors
  2. Press Add custom connector
  3. Paste the address below and press Add
  4. If it asks you to sign in, sign in with the maker
SettingsConnectors1+ Add2https://…3
https://mcp.uniwire.sh/mcp

Run this in your terminal

claude mcp add --transport http uniwire https://mcp.uniwire.sh/mcp

Open in Cursor

Or copy the settings yourself

Paste into .cursor/mcp.json in your project, or ~/.cursor/mcp.json

{
  "mcpServers": {
    "uniwire": {
      "url": "https://mcp.uniwire.sh/mcp"
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

Open in VS Code

Or copy the settings yourself

Paste into .vscode/mcp.json in your project

{
  "servers": {
    "uniwire": {
      "type": "http",
      "url": "https://mcp.uniwire.sh/mcp"
    }
  }
}

Your browser asks to open the app, then the app shows the settings and asks you to confirm. Key values are left empty for you to fill in.

ChatGPT connects only to servers on the internet:

  1. Open ChatGPT on the web → Settings → Connectors (Apps)
  2. Press Create or Add (some plans need Developer mode under Advanced first)
  3. Paste the address below, give it a name and save
  4. If it asks you to sign in, sign in with the maker
SettingsConnectors1+ Create2https://…3
https://mcp.uniwire.sh/mcp

Menu names can differ slightly by plan and over time.

Your choice stays on this device in a cookie; no account needed.

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

What it can do

Tool names and descriptions exactly as the server reported them on Nov 6, 2026. The maker wrote them, not us; we show them as plain text.

  • get_reference_card

    Return the reference card of the uniwire format for electrical diagrams: document skeleton, node types (breakers, RCDs, cables, loads, transformers, PV...) and their fields, enums, links, pitfalls, examples. Read it once before writing a document; type_info gives the fields of on

  • list_types

    List the node types of the format (type, category, label), optionally for one category. Use it to find the type name of a device or load before writing a node; type_info then gives its fields.

  • type_info

    Return every field of one node type with its description, unit and allowed values (enums). Use it before writing or editing a node of that type; list_types gives the type names.

  • validate

    Validate a uniwire document (electrical diagram as JSON) against the format only: structure, types, ids, references and links, without the electrical rules (use check for those). Returns valid + issues, each naming the node id and field when possible, plus viewer_url (the documen

  • check

    Check an electrical installation (single-line diagram, panel, schéma unifilaire, tableau électrique): validates the document, then applies the rule profiles (NF C 15-100 'nfc15100', French grid connection 'enedis', IEC 60364 'iec60364', PLC; default: the document's 'profiles'; 'c

  • describe

    Return a text outline of an electrical diagram: installation, full tree of the panel with stable ids, ratings and cables, links, interlocks, boards and findings summary. Use it to read a document and find the node ids before apply_patch.

  • apply_patch

    Edit an electrical diagram by node id (change a rating, add a circuit, move a load...) and return the new document. ops (applied in order): {"op":"set","id":ID,"path":"in_A","value":20} (null value removes; no id = document root, e.g. path "installation.earthing"); {"op":"add","p

  • render

    Draw the electrical diagram (schéma unifilaire / multifilaire). kind: 'single-line' or 'multi-line'; view: a view id of the document (e.g. a wire-marking view). format 'svg' returns the SVG text of every sheet (or of 'sheet', numbered from 1); 'pdf' writes to 'path' if given, els

  • viewer_link

    Links to a document: viewer_url opens it in the uniwire web editor (drawing, single-line and multi-line, rule findings, PDF and SVG downloads, nothing to install); pdf_url is the PDF drawn by uniwire. On the hosted server the document is kept 30 days so that the short links open

  • wiring

    Wiring exports of an installation as rows with stable column names (repérage des fils, carnet de câbles): what='markers' (one row per wire end, for label printers), 'wires' (wire list) or 'cables' (cable schedule). Marks follow the wire_marking rules of the view (id), by default

  • bom

    Compute the bill of materials (nomenclature) of an electrical installation from its document: one row per manufacturer / part number for the nodes with a product reference, then one row per kind of equipment without a reference (type and main characteristics in 'spec', e.g. 'C16

  • list_examples

    List the 53 example installations (dwellings, shops, offices, workshops, PV, EV charging, UPS, MV/LV substations, PLCs): name, title, language, profiles, earthing, system.

  • get_example

    Return an example installation document by name. Use it as a starting point for a similar installation, then edit it with apply_patch; list_examples gives the names.

  • normalize

    Return the resolved form of a document: templates ('use') applied, every node and link id assigned, numbers in canonical form. Use it to read a document exactly as the rules and drawings see it, or to get stable ids before apply_patch; it does not apply the electrical rules (see

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 8, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account uniwire-dev, which owns the repo

  • … Not checked yet

    Still maintained

    We have not read this repo from GitHub yet

  • … Not checked yet

    Has a licence

    We have not read this repo from GitHub yet

  • ✓ Pass

    Endpoint responds

    Responded in 2344 ms (HTTP 200)

  • – Not applicable

    Sign-in with OAuth

    No sign-in needed

  • ✓ Pass

    No hidden instructions in tool descriptions

    Read 14 tool descriptions and found no hidden instructions to the AI

Compared with others in Design, images & audioi

  • More stars than 0% of the other 2757 servers in this category
  • Published to the registry more recently than 86% of the other 2757 servers in this category
  • Basic checks equal to or better than 100% of the other 2757 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is uniwire safe?

It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs in the maker’s cloud. Connect over the internet with nothing to install, but what you send passes through the maker’s servers.

Is it still maintained?

The GitHub repo last changed –, and the latest version (0.1.8) reached the registry 5 days ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. It connects by URL, so apps that accept remote MCP servers work too, such as ChatGPT in developer mode.

What can I use instead?

In the same category: Figma Context MCP, Claude Real Video, Figma MCP Server

Alternatives

Servers in the same category from other makers, sorted by stars.

Reading a card:★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

Give your coding agent access to your Figma data. Implement designs in any framework in one-shot.

Runs on your computer★ 16,165MITUpdated 5 months ago
Install

Claude Real Video

by HUANGCHIHHUNGLeo

Let any LLM watch a video locally — and search everything it has ever watched.

Runs on your computer★ 2,284MITUpdated 2 months ago
Install

Figma’s official server gives AI your design data so it can turn designs into code or describe them accurately. Connects to Figma’s cloud.

Runs in the cloud★ 2,152Updated 13 months ago
Install

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

uniwire

Electrical diagrams, as code.

An open standard to describe electrical installations, and the reference Python library that validates them, checks them against rules and draws their single-line and multi-line diagrams.

You describe the installation (sources, protective devices, cables, loads, PLCs) in a *.uniwire.json file or in Python, and uniwire computes the drawings. No coordinates, no CAD file: a text file you can review and diff.

Features

  • Single-line and multi-line diagrams from the same document: the multi-line view derives every conductor (L1, L2, L3, N, PE, PEN) from the single-line data, with no extra input.
  • 53 node types: utility grid, transformers, generators, UPS, PV, batteries, inverters; breakers, RCDs, RCBOs, fuses, switch-disconnectors, contactors, motor starters, transfer switches, SPDs, protection relays, instrument transformers, insulation monitors; busbars, boards, terminal blocks; lighting, sockets, heating, motors, EV chargers, modular PLCs and more.
  • Tree + links: the power tree is the backbone; transfers, bus ties, infeeds, earthing, control, interlocks, trips, measurements and data buses are links. A terminal / connectivity-node graph is derived automatically, with CIM, IFC and IEC 61850 SCL mappings.
  • Closed typing and unit-suffixed fields: in_A, idn_mA, section_mm2, p_kW; unknown fields are errors (calibre instead of in_A is caught), extensions live in ext. Templates declare a device once.
  • Rule profiles: core (always), nfc15100 (French dwellings), vde0100 (German installations), iec60364 (cable current-carrying capacity), enedis (connection to the French public network), plus PLC consistency checks.
  • Bill of materials: structured product references (manufacturer, part number, range, accessories) on any node or PLC module, aggregated to CSV (uniwire bom).
  • Wire and cable marking: marking rules per view (manual, sequential, per potential, pattern), marks drawn on the multi-line diagram, and CSV exports: wire list (uniwire wires), wire marker list (uniwire markers), cable schedule (uniwire cables); uniwire marks --write freezes the marks.
  • Colour modes: conductors in their IEC 60445 or North-American colours, or colouring by phase, source, status or voltage level.
  • Sheets: paper size, sub-tree views, automatic sheet splitting with cross-references, circuit schedule, enclosure frames, title block, revisions and notes. SVG output is deterministic and diff-friendly; the multi-sheet PDF has clickable links between sheets.
  • Drawings in English, French, German, Spanish, Portuguese, Italian, Dutch, Polish, Turkish, Russian and Simplified Chinese, selected per document with meta.lang.
  • LLM tooling: a reference card generated from the model (uniwire card), a text outline with stable ids (uniwire describe), id-based edits (uniwire patch), an MCP server (uniwire-mcp, stdio) and a hosted MCP endpoint at https://mcp.uniwire.sh/mcp, plus llms.txt for assistants (full reference card included). Setup for ChatGPT, Claude, Cursor and VS Code: uniwire in your assistant (in ChatGPT, the uniwire plugin of the plugin directory); details in LLM tools.

Gallery

French house, TT (NF C 15-100), single-line

German house, TN-C-S, multi-line in conductor colours

Office building, main LV switchboard

MV/LV substation, 1000 kVA

Standby generator, ATS, load shedding

Motor control centre, multi-line with wire marks

All 53 examples are in examples/ and listed in the documentation; open any of them in the web viewer.

Install

pip install uniwire                 # validation, rules, SVG rendering, bill of materials, exports

pip install "uniwire[pdf]" # + PDF output (reportlab) pip install "uniwire[mcp]" # + MCP server (uniwire-mcp) pip install "uniwire[iec81346]" # + optional IEC 81346-2 class table (separate CC BY-SA 4.0 data package)

Python 3.10 or later. The only required dependency is pydantic.

Quickstart

A document in JSON:

{

"$schema": "https://uniwire.sh/schema/v1/uniwire.schema.json", "uniwire": "1.0.0", "profiles": ["nfc15100"], "meta": { "title": "Small house", "lang": "en" }, "installation": { "earthing": "TT", "system": "1P+N", "un_V": 230 }, "templates": { "C16": { "type": "breaker", "in_A": 16, "curve": "C" } }, "sources": [ { "type": "grid", "label": "Utility", "children": [ { "type": "main_breaker", "ref": "-Q0", "range_A": "15-45", "in_A": 45, "idn_mA": 500, "selective": true, "children": [ { "type": "rcd", "ref": "-Q1", "in_A": 40, "idn_mA": 30, "rcd_type": "AC", "children": [ { "type": "breaker", "ref": "-Q11", "use": "C16", "cable": { "cores": "3G", "section_mm2": 1.5 }, "children": [ { "type": "lighting", "label": "Lighting", "points": 6 } ] } ] }, { "type": "rcd", "ref": "-Q2", "in_A": 40, "idn_mA": 30, "rcd_type": "A", "children": [ { "type": "breaker", "ref": "-Q21", "in_A": 20, "curve": "C", "cable": { "cores": "3G", "section_mm2": 2.5 }, "children": [ { "type": "socket", "label": "Sockets", "points": 8 } ] } ] } ] } ] } ] }

The tree is the power flow (source, protective devices, loads); whatever falls outside the tree (transfer switches, bus ties, control and data connections) goes in links.

uniwire validate house.uniwire.json                 # schema + integrity

uniwire check house.uniwire.json # rule profiles (exit code 1 on errors) uniwire render house.uniwire.json # SVG sheets in out/house/ uniwire render house.uniwire.json -f pdf -o house.pdf uniwire render house.uniwire.json --kind multi-line # multi-line power diagram uniwire bom house.uniwire.json -o house.bom.csv # bill of materials uniwire wires house.uniwire.json # wire list (also: markers, cables, marks) uniwire card # reference card for assistants

The same installation in Python:

from uniwire.build import *

with Installation("Small house", earthing="TT", system="1P+N", un="230 V", profiles=["nfc15100"]) as inst: with Grid("Utility"), MainBreaker("-Q0", "15-45 A", idn="500 mA", selective=True): with RCD("-Q1", "40 A", "30 mA", type="AC"): Breaker("-Q11", "C16", cable="3G1,5") >> Lighting("Lighting", points=6) with RCD("-Q2", "40 A", "30 mA", type="A"): Breaker("-Q21", "C20", cable="3G2,5 18 m") >> Socket("Sockets", points=8)

for finding in inst.check(): print(finding) inst.save("house.uniwire.json") inst.render("house.pdf")

with makes an element the parent of everything created inside it, >> chains elements, ratings and cables are written the way they appear on drawings ("C16", "3G2,5 18 m"). See the code-first API and the Python API and CLI.

Roadmap

  • Terminals, terminal strips and wires: UEP-0001, a draft for format 2.0 (named ports, terminal strips, wires and cables as objects, potentials).
  • Control schematics: coils, auxiliary contacts with cross-references, terminal plans and wire numbers, built on named ports.
  • Exports: DXF drawings, pandapower networks for load-flow and short-circuit studies.

Ideas and format proposals are welcome: see CONTRIBUTING.md.

Contributing

Bug reports, examples, rules, symbols and translations are welcome. Read CONTRIBUTING.md (development setup, tests, uniwire Enhancement Proposals) and the Code of Conduct. Report security issues privately, see SECURITY.md.

Licences

  • Code, CLI and JSON Schema: Apache License 2.0.
  • Specification text: CC BY 4.0: implement it freely, in any software.
  • Optional data package uniwire-data-iec81346 (IEC 81346-2 class table): CC BY-SA 4.0, distributed separately (pip install "uniwire[iec81346]").

See NOTICE for third-party notices.

Ask PopNx