Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Descripción del creador (original en inglés)
MCP server for LabJack T4, T7/T7-Pro and T8 DAQ devices (LJM).
Estos tres nunca se combinan en una sola puntuación: las opiniones, las mediciones y la popularidad son cosas distintas.
Todavía no escribimos un resumen sencillo para este. Abajo están los datos que leímos del registro.
Elige la app de IA que usas y copia la configuración.
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITSNecesitas
¿Qué app usas?
Elige tu app arriba. La recordamos, así que la próxima vez el botón dirá “Instalar en …”.
Abre Claude Desktop → Settings → Developer → Edit Config y pega esto en claude_desktop_config.json
{
"mcpServers": {
"labmcp-labjack": {
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Ejecuta esto en tu terminal
claude mcp add labmcp-labjack --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-labjackCompleta los valores vacíos antes de ejecutarlo.
Pégalo en .cursor/mcp.json de tu proyecto, o en ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-labjack": {
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Tu navegador te pide permiso para abrir la app; luego la app muestra la configuración y te pide confirmar. Los valores de las claves quedan vacíos para que los completes tú.
Pégalo en .vscode/mcp.json de tu proyecto
{
"servers": {
"labmcp-labjack": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}Tu navegador te pide permiso para abrir la app; luego la app muestra la configuración y te pide confirmar. Los valores de las claves quedan vacíos para que los completes tú.
Este se ejecuta en tu computadora, y ChatGPT solo puede conectarse a servidores en internet. Elige otra app.
Tu elección se guarda en una cookie en este dispositivo; no necesitas cuenta.
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envEsta configuración se genera a partir de la ficha del creador en el registro. Si el README dice otra cosa, sigue el README.
Se ejecuta en tu computadora; la lista de herramientas aparece en tu app de IA después de instalarlo.
Revisamos información que cualquiera puede ver; no hemos leído el código. Las revisiones que no aplican no se cuentan. · Revisado el 7 nov 2026
El nombre en el registro se verificó con la cuenta de GitHub K-Dense-AI, dueña del repo
Todavía no hemos leído este repo en GitHub
Todavía no hemos leído este repo en GitHub
Este se ejecuta en tu computadora; no hay endpoint en internet
Se ejecuta en tu computadora y usa ajustes locales en su lugar
Se ejecuta en tu computadora; solo podemos leer listas de herramientas de endpoints en internet
Comparado con todos los servidores activos de esta categoría en el registro. Las estrellas solo cuentan cuando quien lo publica es dueño del repo.
Superó 1 de 1 revisiones básicas aplicables. No hemos leído el código. Antes de agregar una clave o un token, revisa qué acceso pide el servidor y usa una clave que tenga solo los permisos que necesitas.
El registro no indica ninguna clave obligatoria, aunque algunos servidores te piden iniciar sesión la primera vez que los usas.
Se ejecuta en tu computadora. Tu app de IA lo inicia cuando hace falta, y los datos no pasan por los servidores del creador (a menos que el propio servidor llame a un servicio en línea).
El repo de GitHub cambió por última vez –, y la última versión (0.1.3) llegó al registro hace 41 días.
Las apps compatibles con MCP, como Claude Desktop, Claude Code, Cursor y VS Code. También necesitas Python (uv) en tu computadora.
En la misma categoría: Spec Driven Development, Remote Desktop Commander, Foliosio
Servidores de la misma categoría hechos por otros creadores, ordenados por estrellas.
Cómo leer una tarjeta:★ Estrellas de GitHubiTres pilares: reseñas · revisiones · usoiActualizado = fecha en que se publicó la última versión en el registroi
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Read your support inbox, tag conversations and save draft replies from your AI agent. Never sends.
Copiado tal cual del repo del creador. PopNx MCP no lo ha revisado ni lo respalda. Se quitaron HTML, imágenes y scripts. Los enlaces llevan fuera de este sitio.
Let an AI agent read analog inputs, stream waveforms, read thermocouples, check digital lines and (with your permission) set DACs and digital outputs on LabJack T4, T7/T7-Pro and T8 DAQ devices through LabJack's official LJM library.
| Package | labmcp-labjack |
| Instruments | LabJack T4, T7, T7-Pro, T8 (and their OEM versions) |
| Interfaces | USB, Ethernet, WiFi (T7-Pro) |
| Protocol | LJM library + T-series Modbus register map (T-Series Datasheet, register map ljm_constants.json, labjack-ljm Python wrapper) |
| Status | 🧪 simulated: tested against a simulated LJM backend, not yet verified on hardware. Report a hardware test |
uvx labmcp-labjack --simulate --check
uvx labmcp-labjack --simulate --option sim_model=T8 --check # T4, T7, T7-Pro (default) or T8
The simulator wires a 2 V / 10 Hz sine to AIN0, a thermistor divider (~2.5 V) to AIN1, DAC0 back into AIN2, an LM34 cold-junction sensor to AIN3, and a ~37 °C thermocouple to AIN0-AIN3 when the thermocouple feature is used. Other inputs are grounded.
labjack-ljm Python package is installed automatically with this server, but it needs that native library. uvx labmcp-labjack --check # first LabJack found
uvx labmcp-labjack --address 470012345 --check # by serial number uvx labmcp-labjack --address 192.168.1.207 --option connection_type=ETHERNET --check uvx labmcp-labjack --option device_type=T4 --check # only open a T4
`--address` is the LJM identifier: a serial number, an IP address, a device name, or `ANY` (the default).
Claude Code
claude mcp add labjack -- uvx labmcp-labjack --address 470012345
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "labjack": { "command": "uvx", "args": ["labmcp-labjack", "--address", "470012345"] } } }
Add --read-only to allow measurements but block the DAC and digital-output tools (set_outputs_safe stays available). Add --option safe_dio=FIO0,FIO1 to make set_outputs_safe always release those lines, even if another program drove them. For other clients, generate the snippet with uvx labmcp config labjack --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Identify the connected LabJack (model, serial, firmware, connection) and list what it offers: analog inputs, valid input ranges, resolution indices, DAC range, digital lines and stream rate. Call this before configuring channels. |
read_analog_inputs | 👁 read | Read one or more analog inputs once (command-response) and return volts. |
read_device_temperature | 👁 read | Read the LabJack's internal temperature sensor (°C, about ±2 °C) and the estimated ambient air temperature. On the T8 also returns the sensor next to each AIN terminal. Cannot be read while a stream is running. |
read_digital_inputs | 👁 read | Report the logic level and direction (input/output/analog) of digital I/O lines. |
read_thermocouple | 👁 read | Read a thermocouple with the T7/T8 AIN thermocouple extended feature (types B, C, E, J, K, N, R, S, T) and return °C with the measured voltage and cold-junction temperature. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_digital_output | ⚠️ hazard | Make a digital line an output and drive it high (3.3 V) or low (0 V). |
set_outputs_safe | 🛑 safety | Put the outputs in a safe state: stop any stream, set DAC0 and DAC1 to 0 V, and release every digital line this server drove (plus the safe_dio option lines) to input - or drive them low with dio_mode='low'. Use when finished or if anything looks wrong. |
stream_analog | 👁 read | Acquire a hardware-timed waveform on one or more analog inputs (LJM stream mode) and return per-channel statistics plus a downsampled waveform; optionally save everything to CSV. |
write_dac | ⚠️ hazard | Set an analog output (DAC0/DAC1) to a DC voltage. The output stays at this value until changed or set_outputs_safe is called. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log records every LJM register read and write.
| Limit | Default | Meaning |
|---|---|---|
max_dac_voltage_v | 5 V | Highest DAC voltage an agent may set (hardware: T4/T7 0-5 V, T8 0-10 V) |
max_stream_duration_s | 60 s | Longest hardware-timed stream |
max_scan_rate_hz | 10 000 Hz | Highest stream scan rate (the device maximum still applies) |
Override at launch, e.g. --limit max_dac_voltage_v=2.5. Limits are checked before anything is sent. Streams are also capped at 2 million samples in total.
AIN#_RANGE) and resolution indices come from LabJack's register map: T7 ±10/±1/±0.1/±0.01 V and index 0-8 (T7-Pro 0-12, but 9-12 cannot stream); T8 ±11 … ±0.018 V and index 0-16 (one index shared by all inputs); T4 fixed ranges (AIN0-3 ±10 V, AIN4-11 0-2.5 V) and index 0-5. DAC range: T4/T7 0-5 V, T8 0-10 V.read_analog_inputs stay on the device until changed or power-cycled. Omitted settings are left as they are; every reading reports what it was measured against (GND, the T7 negative input, or the T8's isolated terminal).read_digital_inputs uses the DIO_STATE/DIO_DIRECTION bitmasks. (Reading a single-line register such as FIO3 would switch that line to input.)dio_mode="low" instead.AIN#_EF_INDEX 20-30). With cjc="internal" the CJC register is set to its documented default TEMPERATURE_DEVICE_K (address 60052), which the T8 firmware maps to each channel's own terminal sensor (TEMPERATURE#_CAPTURE); cjc="lm34" uses LabJack's LM34 conversion (55.56 K/V, 255.37 K). An open input returns valid=false (the device reports -9999).stream_basic.py example (internal clock, no trigger, auto settling). While a stream runs, command-response analog reads are blocked by the device. Skipped scans (buffer overflow) are reported and left empty. set_outputs_safe does not wait for a running stream: it stops it at the next read (the partial result is returned with aborted: true). A stream runs at 1 scan/s or faster (so that stop is prompt) and always takes at least two scans; that real duration is what the max_stream_duration_s limit checks. The returned waveform is downsampled by keeping each block's minimum and maximum, so short spikes are not lost; save_path must be a new .csv file (an existing file is never overwritten, and the path is checked before streaming).| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |