Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Descripción del creador (original en inglés)
ISO 286 limits and fits, ISO 2768 tolerances, material properties, and process limits.
Estos tres nunca se combinan en una sola puntuación: las opiniones, las mediciones y la popularidad son cosas distintas.
Todavía no escribimos un resumen sencillo para este. Abajo están los datos que leímos del registro.
Elige la app de IA que usas y copia la configuración.
Necesitas
¿Qué app usas?
Elige tu app arriba. La recordamos, así que la próxima vez el botón dirá “Instalar en …”.
Abre Claude Desktop → Settings → Developer → Edit Config y pega esto en claude_desktop_config.json
{
"mcpServers": {
"standards": {
"command": "npx",
"args": [
"-y",
"standards-mcp-server"
]
}
}
}Ejecuta esto en tu terminal
claude mcp add standards -- npx -y standards-mcp-serverPégalo en .cursor/mcp.json de tu proyecto, o en ~/.cursor/mcp.json
{
"mcpServers": {
"standards": {
"command": "npx",
"args": [
"-y",
"standards-mcp-server"
]
}
}
}Tu navegador te pide permiso para abrir la app; luego la app muestra la configuración y te pide confirmar. Los valores de las claves quedan vacíos para que los completes tú.
Pégalo en .vscode/mcp.json de tu proyecto
{
"servers": {
"standards": {
"type": "stdio",
"command": "npx",
"args": [
"-y",
"standards-mcp-server"
]
}
}
}Tu navegador te pide permiso para abrir la app; luego la app muestra la configuración y te pide confirmar. Los valores de las claves quedan vacíos para que los completes tú.
Este se ejecuta en tu computadora, y ChatGPT solo puede conectarse a servidores en internet. Elige otra app.
Tu elección se guarda en una cookie en este dispositivo; no necesitas cuenta.
Esta configuración se genera a partir de la ficha del creador en el registro. Si el README dice otra cosa, sigue el README.
Se ejecuta en tu computadora; la lista de herramientas aparece en tu app de IA después de instalarlo.
Revisamos información que cualquiera puede ver; no hemos leído el código. Las revisiones que no aplican no se cuentan. · Revisado el 6 nov 2026
El nombre en el registro se verificó con la cuenta de GitHub ottonic, dueña del repo
Todavía no hemos leído este repo en GitHub
Todavía no hemos leído este repo en GitHub
Este se ejecuta en tu computadora; no hay endpoint en internet
Se ejecuta en tu computadora y usa ajustes locales en su lugar
Se ejecuta en tu computadora; solo podemos leer listas de herramientas de endpoints en internet
Comparado con todos los servidores activos de esta categoría en el registro. Las estrellas solo cuentan cuando quien lo publica es dueño del repo.
Superó 1 de 1 revisiones básicas aplicables. No hemos leído el código. Antes de agregar una clave o un token, revisa qué acceso pide el servidor y usa una clave que tenga solo los permisos que necesitas.
El registro no indica ninguna clave obligatoria, aunque algunos servidores te piden iniciar sesión la primera vez que los usas.
Se ejecuta en tu computadora. Tu app de IA lo inicia cuando hace falta, y los datos no pasan por los servidores del creador (a menos que el propio servidor llame a un servicio en línea).
El repo de GitHub cambió por última vez –, y la última versión (0.3.0) llegó al registro hace 7 días.
Las apps compatibles con MCP, como Claude Desktop, Claude Code, Cursor y VS Code. También necesitas Node.js en tu computadora.
En la misma categoría: Spec Driven Development, Remote Desktop Commander, Reelsaw
Servidores de la misma categoría hechos por otros creadores, ordenados por estrellas.
Cómo leer una tarjeta:★ Estrellas de GitHubiTres pilares: reseñas · revisiones · usoiActualizado = fecha en que se publicó la última versión en el registroi
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Drive a self-hosted Reelsaw: turn long videos into vertical clips, edit, re-render and export them.
Copiado tal cual del repo del creador. PopNx MCP no lo ha revisado ni lo respalda. Se quitaron HTML, imágenes y scripts. Los enlaces llevan fuera de este sitio.
Reference standards for mechanical engineering, as data an assistant can query: ISO 286 limits and fits, ISO 2768 general tolerances, indicative material properties, and published process feasibility limits. Nothing here comes from a CAD file — it is the reference layer that turns a measurement, or a measurement-plus-drawing question, into an answer you can cite.
Every value is taken from the published tables, carries the edition it came from, and is checked against independent fixtures. Anything the server cannot verify, it refuses with a reason rather than approximating — so a number from this server is one you can put your name to.
| Tool | Returns |
|---|---|
list_standards | Which standards are implemented, and what within each is covered. |
limits_of_size | Upper and lower deviations and limits for one ISO 286 class at one nominal size, e.g. 36H7. |
iso286_applicability | Exact size intervals where one ISO 286 tolerance class is supported, e.g. H7, j5 or N9. |
fit | Fit type, clearance and interference for a hole and shaft pair at one nominal size, e.g. 12 H7/h6. |
it_grade | The standard tolerance value for one IT grade at one size, in micrometres and millimetres (IT01, IT0, IT1–IT18). |
general_tolerance | The ISO 2768-1 general tolerance for a class: linear, broken-edge, or angular. |
general_tolerance_complies | Whether a stated deviation complies with a general-tolerance note. |
material_properties | Typical SI properties for one material designation. |
material_coverage | Which material grades and families are covered. |
process_limits | Published geometric feasibility limits for a process. |
process_feasibility | A check of a stated value against those process limits. |
process_list | Which processes are covered. |
ISO 286-1:2010, with Cor 1:2013 applied provides standard tolerance grades IT01, IT0 and IT1 to IT18 for nominal sizes up to 500 mm. Shaft limits cover c–h, k, m, n, p, r–v, x–z, and za–zc where Table 4/5 publishes a cell, using its exact size intervals and grade rules. Verified hole classes C, D, E, F, G, H, JS, K, M, N, P, R, S, T, U, V, X, Y, Z, ZA, ZB, ZC use the Table 2/3 ∆ corrections and the M6 exception, and grade-specific shaft j5–j7 (and j8 up to 3 mm) and hole J6–J8 use their own table values. iso286_applicability reports the exact supported size intervals for a class; gaps are stated, never interpolated.
ISO 2768-1:1989 provides general tolerances for linear dimensions (classes f, m, c, v), broken edges (classes f and c), and angular dimensions (classes f, c, v), plus a compliance check for a stated deviation.
Materials are indicative typical values for common metals and plastics, from an Apache-2.0 reference, tagged basis: typical. Process limits are published rules of thumb for cnc-machining, sheet-metal, injection-molding, and additive-sls.
Out of scope, and refused rather than guessed: nominal sizes above 500 mm and the inch counterparts (ANSI B4.2); IT01–IT2 K/M/N/P–ZC combinations and sparse Table 2/3 cells with no published ∆ value; design allowables, fatigue, and high-temperature data; and a specific shop's capability, achievable tolerance, cost, or lead time.
The values are the published tables, which are normative. The earlier editions also define the tolerance factor i = 0.45·∛D + 0.001·D and give the grades as multiples of it; that arithmetic reproduces the table at 18 mm and above but diverges at the smallest size step, where the published IT18 is 1400 µm against 2500i = 1355 µm. toleranceFactor() is kept as a documented cross-check, and the tests assert both the table and the divergence.
It reports what a standard specifies. It does not decide whether a design is acceptable, whether a fit suits a joint, or whether a part can be made — those are engineering judgements and they stay with you. Approval, compliance, and certification are out of scope.
npm install
npm run build node dist/src/index.js # serves MCP over stdio
Point an MCP host at dist/src/index.js. The server serves both protocol eras: the 2025-11-25 handshake that stock MCP hosts negotiate, and the 2026-07-28 envelope through server/discover.
just check # fmt-check, lint, typecheck, test
just build just test
just check is keyless and needs no data files: the values are in the source.
npm pack builds first and includes the compiled server and this README; tests and source maps are excluded. Install the tarball to check the standards-mcp executable with a compatible MCP client.
MIT. Third-party notices: THIRD_PARTY_NOTICES.md.