MinerU
Transforms complex documents like PDFs and Office docs into LLM-ready markdown/JSON for your Agentic workflows.
Read, check and what-if Ventsim mine ventilation models (.vsm files)
作者提供的原文
教 AI 做这类工作的 Skill,可与本项一起使用
Transforms complex documents like PDFs and Office docs into LLM-ready markdown/JSON for your Agentic workflows.
Agent skills for Obsidian. Teach your agent to use Obsidian CLI and open formats including Markdown, Bases, JSON Canvas.
列表按使用分(满分 100)排序,由以下部分组成
| 热度 | 0/80 | GitHub 星标或每周下载量:较大的计 60,较小的计 20 |
|---|---|---|
| 新鲜度 | 12/12 | 30 天内有发布或代码更新得满分 |
| 仍在响应 | 0/8 | 上次检查时云端端点有响应 |
| 使用分 | 12/100 |
质量: 基础检查通过 3/3 项(仅展示,不用于排序) · 上升势头: 暂无数据 (只用于“上升中”标签)
选择你使用的 AI 应用,然后复制设置。
用一句话让 AI 帮你安装
请帮我安装 Ventsim。按照 https://mcp.popnx.com/i/agenticeram-ventsim-mcp.md 操作,先把命令给我看,等我同意后再运行。粘贴到能在你电脑上工作的 AI(如 Claude Code、Cursor)。它会读取我们的步骤,先给你看命令,等你同意。无需密钥,无需注册。 · 查看 AI 会读取的全文
通过 3/3 项检查 · 在你的电脑上运行 · ✓ 命令已检查 2026年11月26日
第一步:你用哪个 AI?
选择你用的应用,步骤会显示在下方。
可连接 Claude,但需要先准备
需要先在电脑上安装 Python (uv)(只需一次) · 仅限电脑上的 Claude 应用(Windows 或 Mac),网页和手机不可用
把这段话复制到 Claude 的对话里。AI 会先检查电脑,告诉你要改哪个文件,并且每次都等你同意。
请在这台电脑上为 Claude 安装 MCP server Ventsim,按顺序:1) 用 uv --version 检查是否有 uv。没有的话,请让我从 https://docs.astral.sh/uv/getting-started/installation/ 安装,不要自己安装。2) 只使用这份配置(已通过 PopNx MCP 检查):{ "mcpServers": { "ventsim": { "command": "uvx", "args": [ "ventsim-mcp" ] } } } 3) 告诉我要修改的文件完整路径或要运行的命令,等我同意。4) 不需要密钥。5) 按约定执行,然后确认 Ventsim 的工具真的出现了。这段话不包含你的密钥。如果需要密钥,AI 会请你自己粘贴到文件或应用的输入框里。
已经装好了吗?先检查 · 打开终端,输入这条命令后按 Enter
uv --versionMac:按 ⌘ + Space,输入 Terminal 后按 Enter
Windows:打开“开始”菜单,输入 Windows PowerShell,然后选“打开”
还没安装: uv 没有点选式安装程序。从 uv 官方页面复制适合你系统(macOS 或 Windows)的一行命令,粘贴到终端 · 不需要单独安装 Python,uv 会在需要时自动下载
装好后关掉终端再打开,重新运行同一条命令,应显示版本号: uv --version
安装一次,所有需要 uv 的工具都能用
SettingsDeveloperEdit Config
{
"mcpServers": {
"ventsim": {
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}用 Ventsim 告诉我你能帮我做什么,然后做一件给我看✓ 如果 Claude 说正在使用 Ventsim,或回答中出现 Ventsim 的工具名称,就表示连接成功
菜单名称已于 2026年11月11日 对照 Anthropic 帮助页面核实 · 你的界面可能因版本略有不同
ChatGPT 暂时无法连接 Ventsim
Ventsim 需要安装在你的电脑上,而 ChatGPT 只能连接在网上运行的服务器
可连接 Claude Code,但需要先准备
需要先在电脑上安装 Python (uv)(只需一次)
把这段话复制到 Claude Code 的对话里。AI 会先检查电脑,告诉你要改哪个文件,并且每次都等你同意。
请在这台电脑上为 Claude Code 安装 MCP server Ventsim,按顺序:1) 用 uv --version 检查是否有 uv。没有的话,请让我从 https://docs.astral.sh/uv/getting-started/installation/ 安装,不要自己安装。2) 只使用这份配置(已通过 PopNx MCP 检查):claude mcp add --scope user ventsim -- uvx ventsim-mcp 3) 告诉我要修改的文件完整路径或要运行的命令,等我同意。4) 不需要密钥。5) 按约定执行,然后确认 Ventsim 的工具真的出现了。这段话不包含你的密钥。如果需要密钥,AI 会请你自己粘贴到文件或应用的输入框里。
已经装好了吗?先检查 · 打开终端,输入这条命令后按 Enter
uv --versionMac:按 ⌘ + Space,输入 Terminal 后按 Enter
Windows:打开“开始”菜单,输入 Windows PowerShell,然后选“打开”
还没安装: uv 没有点选式安装程序。从 uv 官方页面复制适合你系统(macOS 或 Windows)的一行命令,粘贴到终端 · 不需要单独安装 Python,uv 会在需要时自动下载
装好后关掉终端再打开,重新运行同一条命令,应显示版本号: uv --version
安装一次,所有需要 uv 的工具都能用
Mac:按 Command+空格,输入 Terminal · Windows:打开 PowerShell
claude mcp add --scope user ventsim -- uvx ventsim-mcp应能看到 Ventsim 在列表中并显示已连接
用 Ventsim 告诉我你能帮我做什么,然后做一件给我看✓ 如果 Claude Code 说正在使用 Ventsim,或回答中出现 Ventsim 的工具名称,就表示连接成功
菜单名称已于 2026年11月11日 对照 Anthropic 帮助页面核实 · 你的界面可能因版本略有不同
可连接 Cursor,但需要先准备
需要先在电脑上安装 Python (uv)(只需一次)
把这段话复制到 Cursor 的对话里。AI 会先检查电脑,告诉你要改哪个文件,并且每次都等你同意。
请在这台电脑上为 Cursor 安装 MCP server Ventsim,按顺序:1) 用 uv --version 检查是否有 uv。没有的话,请让我从 https://docs.astral.sh/uv/getting-started/installation/ 安装,不要自己安装。2) 只使用这份配置(已通过 PopNx MCP 检查):{ "mcpServers": { "ventsim": { "command": "uvx", "args": [ "ventsim-mcp" ] } } } 3) 告诉我要修改的文件完整路径或要运行的命令,等我同意。4) 不需要密钥。5) 按约定执行,然后确认 Ventsim 的工具真的出现了。这段话不包含你的密钥。如果需要密钥,AI 会请你自己粘贴到文件或应用的输入框里。
已经装好了吗?先检查 · 打开终端,输入这条命令后按 Enter
uv --versionMac:按 ⌘ + Space,输入 Terminal 后按 Enter
Windows:打开“开始”菜单,输入 Windows PowerShell,然后选“打开”
还没安装: uv 没有点选式安装程序。从 uv 官方页面复制适合你系统(macOS 或 Windows)的一行命令,粘贴到终端 · 不需要单独安装 Python,uv 会在需要时自动下载
装好后关掉终端再打开,重新运行同一条命令,应显示版本号: uv --version
安装一次,所有需要 uv 的工具都能用
用 Ventsim 告诉我你能帮我做什么,然后做一件给我看✓ 如果 Cursor 说正在使用 Ventsim,或回答中出现 Ventsim 的工具名称,就表示连接成功
菜单名称已于 2026年11月11日 对照 Cursor 帮助页面核实 · 你的界面可能因版本略有不同
可连接 VS Code,但需要先准备
需要先在电脑上安装 Python (uv)(只需一次)
把这段话复制到 VS Code 的对话里。AI 会先检查电脑,告诉你要改哪个文件,并且每次都等你同意。
请在这台电脑上为 VS Code 安装 MCP server Ventsim,按顺序:1) 用 uv --version 检查是否有 uv。没有的话,请让我从 https://docs.astral.sh/uv/getting-started/installation/ 安装,不要自己安装。2) 只使用这份配置(已通过 PopNx MCP 检查):{ "servers": { "ventsim": { "type": "stdio", "command": "uvx", "args": [ "ventsim-mcp" ] } } } 3) 告诉我要修改的文件完整路径或要运行的命令,等我同意。4) 不需要密钥。5) 按约定执行,然后确认 Ventsim 的工具真的出现了。这段话不包含你的密钥。如果需要密钥,AI 会请你自己粘贴到文件或应用的输入框里。
已经装好了吗?先检查 · 打开终端,输入这条命令后按 Enter
uv --versionMac:按 ⌘ + Space,输入 Terminal 后按 Enter
Windows:打开“开始”菜单,输入 Windows PowerShell,然后选“打开”
还没安装: uv 没有点选式安装程序。从 uv 官方页面复制适合你系统(macOS 或 Windows)的一行命令,粘贴到终端 · 不需要单独安装 Python,uv 会在需要时自动下载
装好后关掉终端再打开,重新运行同一条命令,应显示版本号: uv --version
安装一次,所有需要 uv 的工具都能用
用 Ventsim 告诉我你能帮我做什么,然后做一件给我看✓ 如果 VS Code 说正在使用 Ventsim,或回答中出现 Ventsim 的工具名称,就表示连接成功
菜单名称已于 2026年11月11日 对照 VS Code 帮助页面核实 · 你的界面可能因版本略有不同
Claude Code
claude mcp add --scope user ventsim -- uvx ventsim-mcpClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"ventsim": {
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"ventsim": {
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"ventsim": {
"type": "stdio",
"command": "uvx",
"args": [
"ventsim-mcp"
]
}
}
}这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
依据这个服务器的连接方式和各应用自己的文档,检查于 2026年11月10日。
在你的电脑上运行,适用于
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月26日
注册名称已通过 GitHub 账户 agenticeram 验证,该账户拥有此仓库
代码最后更新于今天
使用 MIT
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
尚未检查
如果你是作者,可把这段代码贴到 README。徽章会链接回本页。
[](https://mcp.popnx.com/en/servers/agenticeram-ventsim-mcp)提问、分享技巧或报告无法使用。按“有帮助”数量排序。
还没有评价
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 3 项适用的基础检查中通过了 3 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于今天,最新版本(0.11.0)于今天进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Puter MCP, XcodeBuildMCP, Vexa, Atlassian Rovo MCP Server, MR Office
同一分类、其他作者、命令已通过检查。官方的排在前面,再按星标排序。
如何看卡片:↓ 每周下载量i★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
Puter MCP enables AI tools to interact with Puter: manage files, websites, workers, and more
XcodeBuildMCP provides tools for Xcode project management, simulator management, and app utilities.
Meeting bot and transcripts for Google Meet, Teams and Zoom. Live or after, speakers labelled.
Connect to Atlassian Jira, Confluence, Loom, and more to search, create, and manage your work.
Create, open and edit documents, spreadsheets and PDFs in MR Office's editor, inline in chat.
| 本项 Ventsim | Puter MCP | XcodeBuildMCP | Vexa | Atlassian Rovo MCP Server | MR Office | |
|---|---|---|---|---|---|---|
| 运行位置 | 需要安装在电脑上 | 在云端运行,无需安装 | 需要安装在电脑上 | 在云端运行,无需安装 | 在云端运行,无需安装 | 云端或安装在电脑上都可以 |
| 需要密钥 | 否 | 否 | 否 | 是 | 否 | 否 |
| 可在 Claude 中按 + 添加 | 否 | 否 | 否 | 否 | 是 | 否 |
| 基础检查 | 3/3 | 4/4 | 3/3 | 2/4 | 4/4 | 5/5 |
| 许可证 | MIT | AGPL-3.0 | MIT | Apache-2.0 | Apache-2.0 | AGPL-3.0 |
| 价格 | 登记中未列出费用 | 登记中未列出费用 | 登记中未列出费用 | 登记中未列出费用 | 登记中未列出费用 | 登记中未列出费用 |
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
An MCP server that lets AI assistants read and inspect Ventsim mine ventilation models (.vsm files).
It works on the model file itself, so Ventsim does not need to be running. It reads the geometry, fans and the results Ventsim saved in the file, and has its own experimental airflow, temperature and gas solvers for what-if questions; confirm important results in Ventsim.
Unofficial. Not affiliated with or endorsed by Howden / Chasm Consulting. "Ventsim" is
their trademark. The
.vsmformat is undocumented; it was read from files saved by
Ventsim DESIGN 6 and may change between versions.
| Tool | What it does |
|---|---|
model_summary | Title, Ventsim version, airway and fan counts, total length, depth range |
list_airways | Filter by name/notes or minimum velocity, sort by any field (airflow, length, pressure...) |
get_airway | Every column of one airway |
list_fans | Fan airways with fan model name, duty airflow, fan pressure, power |
velocity_check | Airways above a maximum (or below a minimum) air velocity |
fan_duty_check | Where each fan runs on its curve: airflow per fan, stall margin, flags fans in or near the stall region or off the curve |
fan_summary | Fans by model with total Fan Power as stored in the file (kW) |
compare_models | Diff two saved versions: added/removed airways, airflow and pressure changes |
check_flow_balance | Airflow mass balance at every junction (finds un-simulated or broken networks) |
what_if | Experimental: re-solve the network after scaling airway resistance, switching fans off or changing fan speed, report airflow changes |
size_regulator | Experimental: resistance, pressure drop and approximate opening area of a regulator that brings one airway to a target airflow |
trace_airflow | Main airflow path through an airway from intake to exhaust, with length and frictional pressure along it |
simulate_airflow | Experimental: solve the airflow from the model inputs alone (no saved results needed), with optional changes |
simulate_heat | Experimental: air temperature through the network after airflow changes or with extra heat sources (diesel, fire, coolers) |
contaminant_spread | Experimental: steady-state gas / smoke concentration downstream of release points |
render_network | Draw the network to SVG (plan or section), coloured by any field, fans marked, paths highlighted |
export_csv | Airways to CSV, any columns |
edit_airways | Experimental: write a copy with changed Notes / Group / Branch Name, fan speed or fan on/off, airway size, length or friction factor (resistance follows) |
add_airways | Experimental: write a copy with new airways (copied from an existing one, joined to the network where the ends meet) |
list_airways takes units="imperial" (cfm, fpm, ft, in. w.g., hp).
All values are in the SI units Ventsim stores internally (m, m3/s, Pa, kW).
pip install ventsim-mcp
Claude Desktop / Claude Code config:
{ "mcpServers": { "ventsim": { "command": "ventsim-mcp" } } }
Then ask, for example: *"Open C:\models\mine.vsm and list the 10 airways with the highest velocity."*
A .vsm is a gzip-compressed, CRLF-separated, tab-delimited text file. The airway table starts at a header line beginning MAIN Unique No, which names all ~288 columns; the parser uses those names, never fixed positions. Reading and writing is byte-exact when nothing is edited. A .txt export of the same file (uncompressed) is read too. The CSV/NBC/XLSX exports are headerless or derived dumps of the same tables and are not supported; use the .vsm/.txt.
what_if solves node pressures for the airways of the simulated stage, balancing mass flow (air expands as it warms) with dP = R*Q|Q| - Ps(Q) - NVP on every airway. What it reads from the file:
Stage is a bit mask and an airway that differs between stages is stored once per stage, on top of each other. The stage whose saved airflow balances is used.what_if multiplies it. Closed airways carry no air.Because these inputs come from the saved state, re-solving an unchanged model reproduces Ventsim's airflow almost exactly. That checks the network was read correctly (stages, junctions, closed airways, fans); it is not an accuracy figure for changes (total absolute flow error / total flow, python bench/fit.py ):
| Ventsim DESIGN 6 example | Airways solved | Error |
|---|---|---|
| diamondmine | 1,057 | 0.06 % |
| Tutorial2 | 184 | 0.04 % |
| InclinedHeatMine | 810 | 0.02 % |
| the other 17 examples (CoalMine 3,403 airways, Blue_sky, Fire, HVAC, ...) | < 0.01 % |
Accuracy for changes. Fire and Fire2 are the same network with two airway resistances changed. Predicting Fire2 from Fire plus those two changes (python bench/predict.py Fire.vsm Fire2.vsm) gives an airflow error of 0.03 % of total flow; it reproduces 96.7 % of the airflow change Ventsim computed. This is the only such pair among the shipped examples, so treat it as one data point.
Heat, density and fire effects are not re-evaluated after a change. Treat results as an estimate and confirm in Ventsim.
simulate_airflow does not use any saved result: resistance (Resistance Total), fan curves at their speed and count, fixed-flow airways, fixed-pressure airways (only when Ventsim's flag for it is set), closed airways, ends open to surface and dead ends (read from Ventsim's branch flags). Air is taken as incompressible and natural ventilation is ignored, unless use_saved_heat=True borrows both from the saved results. Compared with the airflow Ventsim saved (python bench/simulate.py ):
| Ventsim DESIGN 6 examples | Error, cold | With saved heat |
|---|---|---|
| CoalMine2, Heat Strategies, Tutorial1, RealMine, DemoMine | 0.0 - 0.2 % | same |
| Tutorial2, DevSolids, RealMine 2 | 0.2 - 1.2 % | same |
| CoalMine, diamondmine, without_ducting, Natural Ventilation Effects | 2 - 4 % | 1.3 - 3.5 % |
| Fire, Fire2, InclinedHeatMine (heat-driven) | 6 - 28 % | 0.6 - 2 % |
| Blue_sky | 8.5 % | 5.4 % |
| HVACDemo, A, B (building ducts with room outlets) | not supported |
The remaining differences come from what the file does not spell out: heat and natural ventilation, how Ventsim applies total-pressure fan curves, leakage on ducts.
simulate_heat carries the dry-bulb temperature along the airflow, fully mixed at junctions. Each airway keeps the sensible heat Ventsim saved for it (rock, diesel, fans, other sources); the auto-compression part of it is split off and follows the new mass flow. Extra sources (kW, negative for cooling) can be added; a stopped fan's power is taken out and a speed change scales it with speed cubed. Changes are reported against the unchanged model, and baseline_fit says how well that matches Ventsim.
Re-running an unchanged model with its saved airflow (python bench/heat.py ) is a reproduction check, not an accuracy figure for changes, because the heat comes from the same saved results. Outlet dry-bulb temperature, airways above 0.5 kg/s, mass-flow weighted mean / 95th percentile / worst single airway of |error|:
| Ventsim DESIGN 6 example | Airways | Mean | p95 | Max |
|---|---|---|---|---|
| Heat Strategies | 30 | 0.03 K | 0.05 K | 0.05 K |
| diamondmine | 761 | 0.17 K | 0.31 K | 2.9 K |
| Natural Ventilation Effects | 186 | 0.18 K | 0.47 K | 0.6 K |
| InclinedHeatMine | 731 | 0.18 K | 0.65 K | 14 K |
| Blue_sky | 506 | 0.33 K | 0.55 K | 6.4 K |
| CoalMine | 1,989 | 0.36 K | 1.6 K | 8.8 K |
| Fire, Fire2 (fire airways) | 147 | 1.1 K | 2.7 K | 11.5 K |
There is no independent check yet: Fire2's saved temperatures are the same as Fire's, so the pair used for airflow says nothing about heat. Moisture (latent heat, wet-bulb) and the change of rock heat with air temperature are not modelled; treat temperatures after large changes as an estimate.
contaminant_spread gives the steady-state concentration of a gas released in airways (m3/s of pure gas): c_out = c_in + G/Q, mixed by airflow at junctions, recirculation included. It is checked against exact hand calculations in the tests only: the mine examples hold time-dependent contaminant results, and the one steady result (dust in HVACDemoB) is in an HVAC model, which is not supported. Reading the model's own source inputs (include_file_sources=True, Base Injection x Base Concentration) is an unverified interpretation of Ventsim's fields and is off by default.
edit_airways accepts Width, Height, Length and kFactor. Area and perimeter follow the airway shape (rectangle, round; other profiles are scaled) and Resistance Total is scaled with the Atkinson relation R ~ k * P * L / A^3, so shock and density factors Ventsim folded into it are kept in proportion. add_airways copies an existing airway to new end points; it does not copy fans, fixed flows or pressures, heat or gas sources. A new end joins the network where it meets an existing airway end (not at a surface connection, which it would close); an end that meets nothing is a dead end unless listed in open_ends. Run simulate_airflow on the copy for the new airflow. Edited and added copies have not yet been opened in Ventsim itself; check them there before relying on them.
Issues and pull requests are welcome; see CONTRIBUTING.md. Questions and ideas go to Discussions.
pip install -e ".[test]"
pytest
MIT licence.