Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server for Inductive Automation Ignition: tags, alarms, history, and Perspective
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
IGNITION_URL, IGNITION_API_TOKEN, IGNITION_BRIDGE_SECRET, IGNITION_ALLOW_WRITES标为机密的值是你账户的钥匙。千万不要分享给别人,也不要粘贴到聊天里。
你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"ignition": {
"command": "uvx",
"args": [
"ignition-mcp"
],
"env": {
"IGNITION_URL": "your-value",
"IGNITION_API_TOKEN": "your-value",
"IGNITION_BRIDGE_SECRET": "your-value",
"IGNITION_ALLOW_WRITES": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add ignition --env IGNITION_URL=your-value --env IGNITION_API_TOKEN=your-value --env IGNITION_BRIDGE_SECRET=your-value --env IGNITION_ALLOW_WRITES=your-value -- uvx ignition-mcp运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"ignition": {
"command": "uvx",
"args": [
"ignition-mcp"
],
"env": {
"IGNITION_URL": "your-value",
"IGNITION_API_TOKEN": "your-value",
"IGNITION_BRIDGE_SECRET": "your-value",
"IGNITION_ALLOW_WRITES": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"ignition": {
"type": "stdio",
"command": "uvx",
"args": [
"ignition-mcp"
],
"env": {
"IGNITION_URL": "your-value",
"IGNITION_API_TOKEN": "your-value",
"IGNITION_BRIDGE_SECRET": "your-value",
"IGNITION_ALLOW_WRITES": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
IGNITION_ALLOW_WRITES env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月7日
注册名称已通过 GitHub 账户 jsgorana 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
你需要填写:IGNITION_URL, IGNITION_API_TOKEN, IGNITION_BRIDGE_SECRET
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.1.3)于4个月前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, EmbeddedCI BenchPod
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Drive a BenchPod hardware-in-the-loop bench: power, flash, UART, I2C, CAN, analog and logic.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
An MCP (Model Context Protocol) server for Inductive Automation Ignition. It gives an AI assistant, Claude Desktop, Claude Code, or any MCP client, structured access to an Ignition gateway: browse and write tags, query history and alarms, manage projects, and deploy full Perspective views.
Tested against Ignition 8.3. 43 tools spanning tags, history, alarms, projects, gateway administration, and Perspective. The server is read-only by default; every write is gated behind an explicit opt-in.
You: "Deploy a Perspective dashboard to a new project called LineOverview with a
gauge bound to [default]Line1/Speed." Claude: (bootstraps the project, writes the view, wires the tag binding, triggers a scan) -> https://gateway:8088/data/perspective/client/LineOverview
Ignition 8.3 ships a native REST API, but it doesn't expose live tag values, tag history, alarm queries, or Perspective view resources. ignition-mcp covers the gap with two transport planes:
/data/api/v1 API, authenticated with an API key, used for projects, gateway configuration, modules, logs, backups, and Perspective session diagnostics.mcp-bridge) you install once on the gateway. It exposes the gateway scripting surface (system.tag.*, system.alarm.*, system.db.*, and project file I/O) over HMAC-signed HTTP requests.Tools that need the bridge degrade with a clear message if it isn't installed. Run ignition_diagnose any time to see what's configured and what's missing.
Gateway web UI -> Config -> Security -> API Keys -> Create. Give it a name, for example claude. Copy the full token; it looks like claude:AbCd....
The key's auto-created security level (Authenticated/ ) needs to be granted gateway read/write access under Config -> Security -> General -> Gateway Read/Write Permissions. Skip this step and calls return HTTP 403; ignition_diagnose will tell you and give the exact fix.
pipx install ignition-mcp
Claude Desktop (claude_desktop_config.json) or Claude Code (.mcp.json):
{
"mcpServers": { "ignition": { "command": "ignition-mcp", "env": { "IGNITION_URL": "http://localhost:8088", "IGNITION_API_TOKEN": "claude:YOUR_SECRET_HERE" } } } }
Restart the client and ask it to run ignition_diagnose. You should get an all-green checklist, aside from a warning about the bridge, which is the next step.
Generate a random secret, enable writes, and let the server install the bridge for you:
"env": {
"IGNITION_URL": "http://localhost:8088", "IGNITION_API_TOKEN": "claude:YOUR_SECRET_HERE", "IGNITION_BRIDGE_SECRET": "a-long-random-string", "IGNITION_ALLOW_WRITES": "true" }
Ask your assistant to install the bridge (this runs the bridge_install tool), then run ignition_diagnose again to confirm the bridge check is green. See docs/bridge.md for the manual install path and troubleshooting.
| Variable | Required | Default | Meaning |
|---|---|---|---|
IGNITION_URL | yes | none | Gateway base URL, e.g. http://localhost:8088 |
IGNITION_API_TOKEN | yes | none | API key, name:secret |
IGNITION_BRIDGE_SECRET | no | unset | HMAC secret for the bridge; bridge tools are disabled without it |
IGNITION_ALLOW_WRITES | no | false | Master switch for every mutating tool |
IGNITION_TLS_VERIFY | no | true | Set to false for self-signed dev gateways |
IGNITION_TIMEOUT_S | no | 30 | Per-request timeout, in seconds |
IGNITION_TAG_WRITE_ALLOWLIST | no | unset | Comma-separated glob patterns; tag writes outside them are refused |
IGNITION_ALLOW_WRITES=true and the call passes confirm=true. Your assistant sets confirm after you approve the action.mcp-bridge logger. Secrets are never logged or echoed back.data/projects/; nothing outside that tree is reachable.| Area | Tools |
|---|---|
| Diagnostics | ignition_diagnose, gateway_info, gateway_trial_status, gateway_trial_reset |
| Tags | tag_browse, tag_read, tag_write, tag_create, tag_config_export, tag_config_import |
| History | history_query, history_providers |
| Alarms | alarm_status, alarm_journal, alarm_acknowledge |
| Projects | project_list, project_get, project_create, project_delete, project_export, project_import, project_scan |
| Perspective | perspective_bootstrap_project, perspective_list_views, perspective_get_view, perspective_upsert_view, perspective_delete_view, perspective_validate_view, perspective_page_config_get/set, perspective_session_props_get, perspective_style_upsert, perspective_list_sessions |
| Gateway admin | gateway_modules, gateway_logs_query, gateway_logger_set_level, gateway_backup, gateway_performance, config_resource_list |
| Database | db_run_named_query, db_query |
| Bridge | bridge_install, bridge_status |
The server also exposes MCP resources the assistant can read to author valid Perspective views: ignition://docs/view-schema and ignition://templates/view/{flex-basic,coordinate-basic,tag-bound-dashboard}.
See docs/perspective-authoring.md for the full writeup. In short: the assistant reads the view-schema resource, starts from a template, validates offline with perspective_validate_view, then deploys with perspective_upsert_view, which validates again, writes the view, and triggers a project scan. A full round-trip example is in examples/deploy-dashboard.md.
git clone https://github.com/jsgorana/ignition-mcp
cd ignition-mcp python -m venv .venv && source .venv/bin/activate pip install -e ".[dev]"
ruff check src tests # lint ruff format --check src tests # format check mypy src # type check pytest tests/unit # unit tests, no gateway needed python bridge/build_zip.py # rebuild the bridge project archive
IGNITION_URL=... IGNITION_API_TOKEN=... IGNITION_BRIDGE_SECRET=... \ IGNITION_ALLOW_WRITES=true python tests/live/live_check.py
Built on the Model Context Protocol and its Python SDK, using httpx for HTTP. The ignition-sdk-examples repository was a useful reference while working out how Ignition's module and scripting APIs fit together.
MIT. See LICENSE.
This project is independent and community-built. It is not affiliated with, endorsed by, or sponsored by Inductive Automation. "Ignition" and "Perspective" are trademarks of Inductive Automation, LLC, used here only to describe compatibility. Test any write-enabled tool against a non-production gateway before pointing it at something that matters.