World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 102 tools.
作者提供的说明(英文原文)
MCP server for IKA hotplate stirrers and overhead stirrers (NAMUR commands).
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"labmcp-ika": {
"command": "uvx",
"args": [
"labmcp-ika"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add labmcp-ika --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-ika运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-ika": {
"command": "uvx",
"args": [
"labmcp-ika"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"labmcp-ika": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-ika"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月10日
注册名称已通过 GitHub 账户 K-Dense-AI 验证,该账户拥有此仓库
代码最后更新于上个月
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 2 项适用的基础检查中通过了 2 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于上个月,最新版本(0.1.1)于上个月进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:World Monitor, Claude Flow, Tldraw
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:↓ 每周下载量i★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 102 tools.
AI orchestration with hive-mind swarms, neural networks, and 87 MCP tools for enterprise dev.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
Let an AI agent heat and stir with IKA hotplate stirrers (C-MAG HS control, IKA Plate / RCT digital) and drive IKA overhead stirrers (EUROSTAR control) through IKA's documented NAMUR interface commands: read plate, probe and medium temperatures, speed and torque; set and start heating and stirring; wait for a temperature; and arm the hotplate's hardware watchdog so it switches itself off if the computer stops talking to it.
| Package | labmcp-ika |
| Instruments | Hotplate stirrers: C-MAG HS 7 control, IKA Plate (RCT digital). Overhead stirrers (--option device=overhead): EUROSTAR 60 control, EUROSTAR 100 control. Other IKA devices with the same NAMUR set are likely to work but are unverified |
| Interfaces | RS-232 (9-pin, PC 1.1 cable), USB (virtual COM port) |
| Protocol | IKA NAMUR commands, "Interfaces and outputs" section of the operating instructions: IKA Plate (RCT digital) (11/2018), C-MAG HS 7 control (11/2018), EUROSTAR 60/100 control (20000003965c). Official downloads: ika.com |
| Status | 🧪 simulated: tested against a wire-level NAMUR simulator, not yet verified on hardware. Report a hardware test |
uvx labmcp-ika --simulate --check
uvx labmcp-ika --simulate --option device=overhead --check # EUROSTAR simulator
uvx labmcp ports uvx labmcp-ika --address /dev/ttyACM0 --check # Linux, hotplate
uvx labmcp-ika --address /dev/tty.usbmodem14101 --check # macOS uvx labmcp-ika --address COM5 --check # Windows uvx labmcp-ika --address COM6 --option device=overhead --check # EUROSTAR
`--check` prints the name the device reports (`IN_NAME`).
Claude Code
claude mcp add ika -- uvx labmcp-ika --address /dev/ttyACM0 --limit max_temperature_c=120
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "ika": { "command": "uvx", "args": ["labmcp-ika", "--address", "/dev/ttyACM0", "--limit", "max_temperature_c=120"] } } }
Add --read-only to allow monitoring only (the stop tools stay available). For other clients: uvx labmcp config ika-stirrer --address /dev/ttyACM0 --client vscode.
| Tool | Kind | Description |
|---|---|---|
disable_watchdog | 🎛 control | Cancel watchdog mode 2 (OUT_WD2@0) and stop the background refresh. Watchdog mode 1 has no cancel command; this tool reports an error for it. |
enable_watchdog | 🎛 control | Arm the hotplate's communication watchdog (OUT_WD1@m / OUT_WD2@m). The server then re-sends the watchdog command in the background; if the computer, this server or the cable fails, the hotplate switches heating and stirring off (mode 1) or falls back to the given safety values (mode 2) after timeout_s. Note: stopping or reconnecting the server also stops the refresh, so the watchdog trips unless you enable it again. Mode 1 cannot be cancelled over the interface. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_status | 👁 read | Read temperatures, stirring speed and setpoints. On hotplates: plate and external-probe temperature, temperature setpoint and the device's safety-circuit temperature. On overhead stirrers: PT1000 probe temperature, torque and the speed/torque limits set on the device. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_speed | ⚠️ hazard | Set the stirring speed setpoint (OUT_SP_4). Does not start the motor; if it is already running, the speed changes immediately. Refused above max_speed_rpm (and, on overhead stirrers, above the speed limit set on the device). |
set_temperature | ⚠️ hazard | Set the hotplate temperature setpoint (OUT_SP_1). With an external probe connected this is the target temperature of the medium. Does not start heating; if heating is already on, the plate starts moving to the new setpoint immediately. Refused above max_temperature_c or above the device's own safety-circuit temperature. |
start_heating | ⚠️ hazard | Switch the hotplate heater on (START_1). It heats towards the current setpoint, which is checked against max_temperature_c first. Make sure the vessel and its contents can take the setpoint temperature and that nothing flammable is near the plate. |
start_stirring | ⚠️ hazard | Start the stirring motor (START_4) at the current speed setpoint, which is checked against max_speed_rpm first. Make sure the stir bar or impeller is in place and the vessel is secured (a decoupled stir bar or an unclamped vessel can splash). |
stop_all | 🛑 safety | Emergency stop: switch the heater off (hotplates) and stop the motor. Every stop command is sent even if one of them fails. Also ends a running wait_for_temperature. |
stop_heating | 🛑 safety | Switch the hotplate heater off (STOP_1). Stirring continues. The plate stays hot for a long time after switching off. |
stop_stirring | 🛑 safety | Stop the stirring motor (STOP_4). Heating (if on) continues. |
wait_for_temperature | 👁 read | Poll a temperature until it is within tolerance_c of the target for stable_for_s seconds, or until timeout_s passes. Does not change anything on the device (start heating first). Returns whether the target was reached plus a short temperature trace. A stop command ends the wait early. |
| Limit | Default | Meaning |
|---|---|---|
max_temperature_c | 150 °C | Highest hotplate setpoint an agent may set (also checked before start_heating, and for the watchdog fallback temperature) |
max_speed_rpm | 1000 rpm | Highest stirring speed an agent may set (also checked before start_stirring) |
max_wait_s | 3600 s | Longest wait_for_temperature |
Override at launch, e.g. --limit max_temperature_c=250 --limit max_speed_rpm=1500. On top of these, the hotplate refuses setpoints above its own safety-circuit temperature (set with the screwdriver dial on the device, read with IN_SP_3), and overhead stirrers refuse speeds above the speed limit set in the device menu (IN_SP_6); the server checks both before sending.
--option device=hotplate. Overhead stirrers need --option device=overhead; they have no heater, report their PT1000 probe on IN_PV_3 and torque on IN_PV_5. Tools that don't apply to the configured type return a clear error and send nothing.get_status reports the last start/stop *this server* sent (heating_commanded, stirring_commanded) and None when unknown. The front-panel buttons can change it without the server knowing.set_temperature / set_speed (IN_SP_1 / IN_SP_4), and a warning is returned if the device reports a different value.OUT_WD1@m / OUT_WD2@m, 20–1500 s): enable_watchdog arms it and the server re-sends the command in the background every quarter of the watchdog time. If the server or the computer dies or the cable is pulled, the hotplate switches heating and stirring off (mode 1) or falls back to the safety temperature and speed (mode 2). Stopping or reconnecting the server also stops the refresh, so the watchdog trips. Mode 1 has no documented cancel command; mode 2 is cancelled with OUT_WD2@0. The manual's watchdog error codes differ between sections (ER 2 vs Err. 1/Err. 2); a trip is visible on the display, not over the interface.25.3 2), so both forms work. The value reported by IN_PV_1 when no external probe is plugged in is not documented; ignore external_temperature_c if you have no probe.0x20 0x0D 0x0A.SET_MODE_n (changes the power-on operating mode A/B/D, a persistent setting) and RESET; overhead-stirrer torque/speed-limit writes (OUT_SP_5/6/8) and direction change (OUT_MODE_n).| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|