Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server for LabJack T4, T7/T7-Pro and T8 DAQ devices (LJM).
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"labmcp-labjack": {
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add labmcp-labjack --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-labjack运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-labjack": {
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"labmcp-labjack": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月8日
注册名称已通过 GitHub 账户 K-Dense-AI 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.1.3)于42天前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, A1RO — Irish employment tools
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Irish temp worker cost, public holiday pay and holidays, and SafeHandle certificate checks.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
Let an AI agent read analog inputs, stream waveforms, read thermocouples, check digital lines and (with your permission) set DACs and digital outputs on LabJack T4, T7/T7-Pro and T8 DAQ devices through LabJack's official LJM library.
| Package | labmcp-labjack |
| Instruments | LabJack T4, T7, T7-Pro, T8 (and their OEM versions) |
| Interfaces | USB, Ethernet, WiFi (T7-Pro) |
| Protocol | LJM library + T-series Modbus register map (T-Series Datasheet, register map ljm_constants.json, labjack-ljm Python wrapper) |
| Status | 🧪 simulated: tested against a simulated LJM backend, not yet verified on hardware. Report a hardware test |
uvx labmcp-labjack --simulate --check
uvx labmcp-labjack --simulate --option sim_model=T8 --check # T4, T7, T7-Pro (default) or T8
The simulator wires a 2 V / 10 Hz sine to AIN0, a thermistor divider (~2.5 V) to AIN1, DAC0 back into AIN2, an LM34 cold-junction sensor to AIN3, and a ~37 °C thermocouple to AIN0-AIN3 when the thermocouple feature is used. Other inputs are grounded.
labjack-ljm Python package is installed automatically with this server, but it needs that native library. uvx labmcp-labjack --check # first LabJack found
uvx labmcp-labjack --address 470012345 --check # by serial number uvx labmcp-labjack --address 192.168.1.207 --option connection_type=ETHERNET --check uvx labmcp-labjack --option device_type=T4 --check # only open a T4
`--address` is the LJM identifier: a serial number, an IP address, a device name, or `ANY` (the default).
Claude Code
claude mcp add labjack -- uvx labmcp-labjack --address 470012345
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "labjack": { "command": "uvx", "args": ["labmcp-labjack", "--address", "470012345"] } } }
Add --read-only to allow measurements but block the DAC and digital-output tools (set_outputs_safe stays available). Add --option safe_dio=FIO0,FIO1 to make set_outputs_safe always release those lines, even if another program drove them. For other clients, generate the snippet with uvx labmcp config labjack --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Identify the connected LabJack (model, serial, firmware, connection) and list what it offers: analog inputs, valid input ranges, resolution indices, DAC range, digital lines and stream rate. Call this before configuring channels. |
read_analog_inputs | 👁 read | Read one or more analog inputs once (command-response) and return volts. |
read_device_temperature | 👁 read | Read the LabJack's internal temperature sensor (°C, about ±2 °C) and the estimated ambient air temperature. On the T8 also returns the sensor next to each AIN terminal. Cannot be read while a stream is running. |
read_digital_inputs | 👁 read | Report the logic level and direction (input/output/analog) of digital I/O lines. |
read_thermocouple | 👁 read | Read a thermocouple with the T7/T8 AIN thermocouple extended feature (types B, C, E, J, K, N, R, S, T) and return °C with the measured voltage and cold-junction temperature. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_digital_output | ⚠️ hazard | Make a digital line an output and drive it high (3.3 V) or low (0 V). |
set_outputs_safe | 🛑 safety | Put the outputs in a safe state: stop any stream, set DAC0 and DAC1 to 0 V, and release every digital line this server drove (plus the safe_dio option lines) to input - or drive them low with dio_mode='low'. Use when finished or if anything looks wrong. |
stream_analog | 👁 read | Acquire a hardware-timed waveform on one or more analog inputs (LJM stream mode) and return per-channel statistics plus a downsampled waveform; optionally save everything to CSV. |
write_dac | ⚠️ hazard | Set an analog output (DAC0/DAC1) to a DC voltage. The output stays at this value until changed or set_outputs_safe is called. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log records every LJM register read and write.
| Limit | Default | Meaning |
|---|---|---|
max_dac_voltage_v | 5 V | Highest DAC voltage an agent may set (hardware: T4/T7 0-5 V, T8 0-10 V) |
max_stream_duration_s | 60 s | Longest hardware-timed stream |
max_scan_rate_hz | 10 000 Hz | Highest stream scan rate (the device maximum still applies) |
Override at launch, e.g. --limit max_dac_voltage_v=2.5. Limits are checked before anything is sent. Streams are also capped at 2 million samples in total.
AIN#_RANGE) and resolution indices come from LabJack's register map: T7 ±10/±1/±0.1/±0.01 V and index 0-8 (T7-Pro 0-12, but 9-12 cannot stream); T8 ±11 … ±0.018 V and index 0-16 (one index shared by all inputs); T4 fixed ranges (AIN0-3 ±10 V, AIN4-11 0-2.5 V) and index 0-5. DAC range: T4/T7 0-5 V, T8 0-10 V.read_analog_inputs stay on the device until changed or power-cycled. Omitted settings are left as they are; every reading reports what it was measured against (GND, the T7 negative input, or the T8's isolated terminal).read_digital_inputs uses the DIO_STATE/DIO_DIRECTION bitmasks. (Reading a single-line register such as FIO3 would switch that line to input.)dio_mode="low" instead.AIN#_EF_INDEX 20-30). With cjc="internal" the CJC register is set to its documented default TEMPERATURE_DEVICE_K (address 60052), which the T8 firmware maps to each channel's own terminal sensor (TEMPERATURE#_CAPTURE); cjc="lm34" uses LabJack's LM34 conversion (55.56 K/V, 255.37 K). An open input returns valid=false (the device reports -9999).stream_basic.py example (internal clock, no trigger, auto settling). While a stream runs, command-response analog reads are blocked by the device. Skipped scans (buffer overflow) are reported and left empty. set_outputs_safe does not wait for a running stream: it stops it at the next read (the partial result is returned with aborted: true). A stream runs at 1 scan/s or faster (so that stop is prompt) and always takes at least two scans; that real duration is what the max_stream_duration_s limit checks. The returned waveform is downsampled by keeping each block's minimum and maximum, so short spikes are not lost; save_path must be a new .csv file (an existing file is never overwritten, and the path is checked before streaming).| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |