Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server for microscopes controlled by Micro-Manager (pymmcore-plus).
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"labmcp-micro-manager": {
"command": "uvx",
"args": [
"labmcp-micro-manager"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add labmcp-micro-manager --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-micro-manager运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-micro-manager": {
"command": "uvx",
"args": [
"labmcp-micro-manager"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"labmcp-micro-manager": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-micro-manager"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月8日
注册名称已通过 GitHub 账户 K-Dense-AI 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.1.3)于42天前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, Tethered Trust
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Fit, compatibility and recall checks for AI agents before they buy: verdicts, evidence, receipts.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
Let an AI agent snap images, acquire z-stacks and time-lapses, move the stage and focus within limits you set, switch channels and objectives, set exposure, operate shutters and run autofocus on any microscope controlled by Micro-Manager, through its open device layer (MMCore) and pymmcore-plus.
| Package | labmcp-micro-manager |
| Instruments | Any hardware with a Micro-Manager device adapter (hundreds of cameras, XY/Z stages, microscope stands, filter wheels, shutters and light sources from Hamamatsu, Photometrics, Andor, PCO, Basler, ASI, Prior, Ludl, Märzhäuser, Nikon, Zeiss, Olympus/Evident, Leica, Lumencor, CoolLED and others), described by a Micro-Manager .cfg hardware configuration |
| Interfaces | Whatever the device adapters use: USB, serial, Camera Link / CoaXPress / GigE frame grabbers |
| Protocol | Micro-Manager MMCore API via pymmcore-plus CMMCorePlus (MMCore API reference, pymmcore-plus API, configuration guide) |
| Status | 🧪 simulated: tested against a simulated microscope and against pymmcore-plus' real core with Python test devices, not yet verified on hardware. Report a hardware test |
uvx labmcp-micro-manager --simulate --check
The simulator is a widefield fluorescence microscope with a 512 x 512, 12-bit camera, an XY stage, a focus drive, a shutter, a DAPI / FITC / TRITC / Brightfield filter wheel, a 10x / 20x / 40x turret and a hardware autofocus, looking at a field of cell nuclei. Its images defocus with Z, scale with exposure, bleach with light dose, saturate at 4095 and carry shot and read noise, so focusing, exposure and bleaching behave like on a real microscope.
.cfg file with Micro-Manager's Hardware Configuration Wizard (in the Micro-Manager app), including config groups for channels (usually Channel) and objectives (Objective) and a pixel-size calibration. Close the Micro-Manager app afterwards: a device can only be opened by one program.pymmcore build. Either download them with pymmcore-plus' own installer: uvx --from labmcp-micro-manager mmcore install # into pymmcore-plus' data folder
uvx --from labmcp-micro-manager mmcore list # show what was found
or point to an existing Micro-Manager installation with `--option mm_path=/path/to/Micro-Manager` (it must be a build whose device interface matches pymmcore; `mmcore info` shows the version). Vendor camera SDKs and drivers must be installed separately, as for Micro-Manager itself.
uvx labmcp-micro-manager --address ~/scopes/Ti2_Prime95B.cfg --check
uvx labmcp-micro-manager --address MMConfig_demo.cfg --check # Micro-Manager demo devices
`--check` loads the configuration and prints the camera, stages and other device roles.
Claude Code
claude mcp add microscope -- uvx labmcp-micro-manager --address /path/to/MyScope.cfg --option z_min_um=0 --option z_max_um=4500
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "microscope": { "command": "uvx", "args": ["labmcp-micro-manager", "--address", "/path/to/MyScope.cfg", "--option", "z_min_um=0", "--option", "z_max_um=4500", "--option", "data_dir=/data/microscope"] } } }
Add --read-only to let the agent read positions and settings without imaging or moving anything (stop_stage and close_shutter stay available). For other clients, generate the snippet with uvx labmcp config micro-manager --address /path/to/MyScope.cfg --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
acquire_time_lapse | ⚠️ hazard | Acquire a time-lapse at the current position: images every interval_s (optionally several channels per timepoint), saves a multi-page TIFF and reports per-frame statistics and the intensity change (bleaching). Bounded by max_frames and max_acquisition_duration_s; stop_stage aborts it. |
acquire_z_stack | ⚠️ hazard | Acquire a z-stack around the current focus: moves Z through the slices (optionally imaging several channels at each), saves a multi-page TIFF, reports per-slice statistics and the sharpest slice, and returns Z to where it started. Every slice must stay within max_z_step_um of the start and the Z soft limits. |
autofocus | ⚠️ hazard | Run the configured autofocus device (e.g. a hardware focus lock) once; it moves the focus drive. If the result is outside the Z step or soft limits, the focus is moved back and an error is raised. |
close_shutter | 🛑 safety | Close the shutter (stop illuminating the sample) and abort any running acquisition. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_exposure | 👁 read | Return the camera exposure time in milliseconds. |
get_position | 👁 read | Read the XY stage and focus (Z) positions in micrometres, and which way increasing Z moves the objective. |
get_system_info | 👁 read | Describe the microscope: loaded devices (camera, stages, shutters, filter wheels...), which device has which role, camera size/bit depth/exposure, pixel size, config groups with their presets, the current position, and the soft limits. Call this first. |
list_config_groups | 👁 read | List Micro-Manager config groups (e.g. Channel, Objective) with their presets and the preset currently active. |
move_stage_xy | ⚠️ hazard | Move the XY stage. Moves longer than max_xy_step_um or outside the XY soft limits are refused before anything moves. Make sure the objective and condenser clear the sample holder. |
move_z | ⚠️ hazard | Move the focus drive (Z). Moving the objective toward the sample can crash it into the slide: moves larger than max_z_step_um or outside the Z soft limits are refused before anything moves. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_config | 🎛 control | Apply a config-group preset (e.g. switch the channel: filter cube, light source, emission filter). Objective/turret groups are refused here: use set_objective. |
set_exposure | 🎛 control | Set the camera exposure time (ms). Longer exposures give brighter images but more photobleaching. Returns the exposure the camera accepted. |
set_objective | ⚠️ hazard | Switch the objective (rotates the nosepiece/turret). A longer or immersion objective can hit the sample holder or need oil/water: confirm with the user first. Pixel size changes with the objective. |
set_shutter | ⚠️ hazard | Open or close the current shutter, and optionally switch auto-shutter. An open shutter illuminates (and bleaches) the sample until it is closed again. |
snap_image | 🎛 control | Acquire one image with the current channel, exposure and position. The sample is illuminated during the exposure. Saves the full image as TIFF and returns summary statistics (min/max/mean, saturation, sharpness) plus an optional contrast-stretched preview. |
stop_stage | 🛑 safety | Immediately stop XY and Z stage motion and abort any z-stack or time-lapse in progress. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. get_command_log lists every state-changing MMCore call (setPosition(1502.0), setConfig('Channel', 'FITC'), snapImage(), ...).
| Limit | Default | Meaning |
|---|---|---|
max_z_step_um | 50 µm | Largest focus move from the current position (also the largest z-stack offset, and the largest autofocus correction accepted) |
max_xy_step_um | 20000 µm | Largest XY stage move in one call (straight-line distance) |
max_exposure_ms | 10000 ms | Longest camera exposure |
max_frames | 500 | Most images in one z-stack or time-lapse (slices or timepoints x channels) |
max_acquisition_duration_s | 3600 s | Longest time-lapse (one tool call can run at most 3600 s whatever this is set to) |
Override at launch, e.g. --limit max_z_step_um=10 --limit max_frames=2000.
Soft limits (recommended): absolute stage bounds in micrometres, set with driver options. Find them by moving to the safe extremes in Micro-Manager (e.g. Z with the objective just below the coverslip) and reading the positions:
| Option | Meaning |
|---|---|
z_min_um, z_max_um | Allowed focus range. Set the side that moves the objective toward the sample tightly. |
x_min_um, x_max_um, y_min_um, y_max_um | Allowed XY range (e.g. the area of your slide or plate holder) |
Every Z and XY move, every z-stack slice and every autofocus result is checked against the step limits and soft limits before anything moves (autofocus results are checked afterwards and undone if out of range).
get_position / get_system_info report focus_direction (whether increasing Z moves the objective toward the sample, as declared by the device adapter; often unknown). Configure z_min_um / z_max_um for every microscope you connect.set_objective) rotate the nosepiece and are marked as hazardous; set_config refuses config groups whose names look like objective or turret groups (Objective, Nosepiece, Turret, Magnification, Lens). Other groups are applied as-is: if one of your presets moves hardware near the sample, name the group accordingly or leave it out of the configuration.set_shutter(open=True) leaves the sample lit until close_shutter is called.save_path, or in --option data_dir=... (default: the system temp folder, labmcp-micro-manager/). save_path must end in .tif/.tiff and must not be a folder; it is checked before anything moves or is exposed. Existing files are never overwritten (a numeric suffix is added). Tools return statistics (min/max/mean/std, saturated fraction, a sharpness score) and a small contrast-stre只显示了开头部分;其余内容请在仓库中阅读