Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server that builds and validates LC-MS worklists for MassLynx, SCIEX OS, MassHunter, Xcalibur.
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"labmcp-ms-worklist": {
"command": "uvx",
"args": [
"labmcp-ms-worklist"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add labmcp-ms-worklist --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-ms-worklist运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-ms-worklist": {
"command": "uvx",
"args": [
"labmcp-ms-worklist"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"labmcp-ms-worklist": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-ms-worklist"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月8日
注册名称已通过 GitHub 账户 K-Dense-AI 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.1.1)于42天前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, Readfirst
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:↓ 每周下载量i★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
What to read and check before changing a file: project rules, risks, checks and tests per file.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
Let an AI agent build LC-MS sample queues (worklists, sequences, batches) and export them as import files for Waters MassLynx, SCIEX OS, Agilent MassHunter Acquisition and Thermo Xcalibur. The agent can lay out samples on a tray, insert blanks and QCs, randomise the run order with a recorded seed, check the list for mistakes, convert an existing file from one vendor to another, and write the file for a person to import. It uses only documented import formats. It never starts an acquisition and doesn't talk to the mass spectrometer.
| Package | labmcp-ms-worklist |
| Software | Waters MassLynx 4.x, SCIEX OS, Agilent MassHunter Acquisition (LC/TQ, LC/Q-TOF), Thermo Xcalibur 2.2+ |
| Interfaces | File (writes CSV/TXT import files into one output folder) |
| Protocol | Vendor sample-list import formats (see Formats for sources) |
| Status | 🧪 simulated: tested with golden files and round-trip tests, not yet imported into the vendor software by us. Report a test |
uvx labmcp-ms-worklist --simulate --check
--simulate uses a temporary output folder that is deleted when the server stops. Everything else is the same code.
The "instrument address" is the output folder where worklist files are written (default ./worklists, created if missing):
uvx labmcp-ms-worklist --address "D:\Worklists" --check # Windows acquisition PC or a shared drive
uvx labmcp-ms-worklist --address ~/lcms/worklists --check # macOS / Linux, then copy the files over
.., absolute paths elsewhere and symlinks that point outside it. It never overwrites an existing file unless the agent passes overwrite=true.--address at a folder the acquisition software watches only if the vendor documents that behaviour for your setup. Otherwise import the file by hand (instructions below).Claude Code
claude mcp add ms-worklist -- uvx labmcp-ms-worklist --address ~/lcms/worklists
Claude Desktop / Cursor / Windsurf
{
"mcpServers": { "ms-worklist": { "command": "uvx", "args": ["labmcp-ms-worklist", "--address", "/path/to/worklists"] } } }
--read-only keeps only the tools that inspect things (list_formats, validate_worklist, import_worklist, get_worklist, list_worklists).
| Tool | Kind | Description |
|---|---|---|
add_samples | 🎛 control | Append samples to a draft worklist (the worklist's defaults and automatic positions apply; any blank/QC/randomisation plan is re-applied to the longer list with the same seed). |
create_worklist | 🎛 control | Create an in-memory draft worklist from a sample list plus defaults (methods, injection volume, tray positions, data-file naming pattern). Nothing is written to disk until export_worklist. Injection volumes above the max_injection_volume_ul limit are refused. |
export_worklist | 🎛 control | Validate the draft and write the vendor import file into the output folder. Returns the path, a preview of the first lines, warnings and import instructions. Refuses if validation finds errors or the file exists (unless overwrite=true). This does not start an acquisition: a person imports the file into the acquisition software. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_worklist | 👁 read | Show a draft worklist in run order, with its defaults, blank/QC plan, randomisation seed and the history of operations applied to it. |
import_worklist | 👁 read | Parse an existing MassLynx, SCIEX OS, MassHunter or Xcalibur import file from the output folder into a draft, so it can be validated, edited or exported in another vendor's format. Columns without a neutral equivalent are kept verbatim. Only reads; nothing is written. |
insert_qc_blanks | 🎛 control | Insert blanks and QC injections and optionally randomise the run order (with a recorded seed). Replaces any previous plan, so calling it again does not duplicate blanks. The plan is re-applied whenever samples are added; data-file names follow the new run order. |
list_formats | 👁 read | List the supported import formats (Waters MassLynx, SCIEX OS, Agilent MassHunter, Thermo Xcalibur): columns, required fields, sample-type names, file extensions, how to import, what is verified against vendor documents and what is assumed, and the source URLs. Also lists the position patterns and the formats that were researched but not implemented. |
list_worklists | 👁 read | List the draft worklists in memory and the files in the output folder. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
validate_worklist | 👁 read | Check a draft against the target format: required fields, duplicate data-file names, characters Windows does not allow in file names, tray/vial position format and plate bounds, injection volume (> 0 and <= the max_injection_volume_ul limit), and method file extensions. Errors block export; warnings don't. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. There are no HAZARD tools: nothing here moves, heats, injects or acquires. The server only writes files. The CONTROL tools change in-memory drafts or write a file, and --read-only hides them.
Typical flow: create_worklist → add_samples (optional) → insert_qc_blanks → validate_worklist → export_worklist, then import the file in the vendor software.
The table below separates what the vendor documents say (verified) from what the server assumes. list_formats returns the same information to the agent. To be sure of the header for your software version, export an empty batch, sequence or worklist from your own system, put it in the output folder, and pass it to export_worklist as template_path. The server then writes that header, and that delimiter, exactly.
waters_masslynx)Index column is added. Source: WKB63781.FILE_NAME, INLET_FILE, MS_FILE, SAMPLE_LOCATION and INJ_VOL. Source: MassLynx 4.2 Getting Started Guide 715009602, Table 5-1. The "Bottle" column's FIELD ID is SAMPLE_LOCATION, not BOTTLE.TYPE values Blank/Standard/QC/Analyte, and method names without an extension.FILE_NAME = data file, FILE_TEXT = sample name, MS_FILE, MS_TUNE_FILE, INLET_FILE, SAMPLE_LOCATION, TYPE, ID, INJ_VOL, Index. You can add any other FIELD ID (for example CONC_A or QUAN_REF) per sample through extra.solvent and double_blank are written as Blank..exp for MS_FILE and .ipr for the tune file, applied only when an extension is given.waters_plate_well position pattern (1:A,1) is a common convention. Its comma is CSV-quoted.sciex_os).txt or .csv, and the column layout must come from a batch exported from SCIEX OS. Source: SCIEX KB.Sample Name,Sample ID,Sample Type,MS Method,LC Method,Rack Type,Rack Position,Plate Type,Plate Position,Vial Position,Injection Volume,Data File,Processing Method,Comment) is a best guess. Use template_path with your own export. validate_worklist and export_worklist warn when no template was used..msm, .lcm and .qmethod produce warnings only.vendor_columns or per sample with extra.agilent_masshunter)Sample Name,Barcode,Rack Code,Sample Position,Method,Data File,Sample Type,Level Name,Inj Vol (µL),Comment, positions like P1-A1, and the types Calibration and Sample come from the example file shipped in D:\MassHunter\Worklist_Import, as quoted on the Agilent Community.Inj Vol = -1 means "As method". Source: Agilent Known Problem Report..d suffix..m.solvent is written as Blank.thermo_xcalibur).csv files are accepted.Bracket Type=n (1 Overlapped, 2 None, 3 Non-Overlapped, 4 Open).只显示了开头部分;其余内容请在仓库中阅读