Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server for Rigol oscilloscopes (DS1000Z, MSO5000, DHO series): measurements and waveforms.
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"labmcp-rigol-scope": {
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add labmcp-rigol-scope --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-rigol-scope运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-rigol-scope": {
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"labmcp-rigol-scope": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月8日
注册名称已通过 GitHub 账户 K-Dense-AI 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.1.2)于42天前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, UniMCP
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:↓ 每周下载量i★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Aula virtual (Moodle) y SIU Guaraní de universidades argentinas: cursos, entregas, notas, historia.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
Let an AI agent read the setup, adjust channels, timebase and trigger, run single acquisitions, take the scope's own measurements, capture calibrated waveforms and grab screenshots on Rigol digital oscilloscopes over SCPI.
| Package | labmcp-rigol-scope |
| Instruments | DS1000Z / MSO1000Z (DS1054Z, DS1074Z, DS1104Z, MSO1104Z, "Plus" models), DS1000Z-E (DS1102Z-E, DS1202Z-E), MSO5000 (MSO5072 … MSO5354), DHO800 / DHO900 (DHO802, DHO804, DHO914, DHO924), DHO1000 / DHO4000 (DHO1072 … DHO4804) |
| Interfaces | USB (USB-TMC), LAN (VXI-11/LXI, raw socket) |
| Protocol | SCPI per Rigol's programming guides: MSO1000Z/DS1000Z PGA19109-1110, DS1000Z-E PGA27100-1110, MSO5000 PGA25104-1110, DHO800/DHO900, DHO1000/DHO4000 PGA34101-1110 |
| Status | 🧪 simulated: tested against a wire-level SCPI simulator (including binary waveform and screenshot blocks), not yet verified on hardware. Report a hardware test |
uvx labmcp-rigol-scope --simulate --check
uvx labmcp-rigol-scope --simulate --option sim_model=DHO804 --check # also DS1202Z-E, MSO5074, DHO1204 ...
The simulated scope has a 1 kHz, 0-3 V square wave on CH1 and a 2 kHz, 1 V sine on CH2 (CH3/CH4 grounded). It answers :WAVeform:DATA? and :DISPlay:DATA? with real IEEE 488.2 binary blocks, keeps an SCPI error queue, and its trigger only fires when the level is inside the signal, so you can try single with a bad trigger level.
pyvisa-py backend, which needs libusb on the system (brew install libusb, apt install libusb-1.0-0; on Windows use NI-VISA with ?backend=@ivi). Find the resource with python -m pyvisa info or uvx labmcp ports. uvx labmcp-rigol-scope --address USB0::0x1AB1::0x04CE::DS1ZA123456789::INSTR --check # USB-TMC
uvx labmcp-rigol-scope --address TCPIP0::192.168.1.50::INSTR --check # LAN (VXI-11) uvx labmcp-rigol-scope --address tcp://192.168.1.50:5555 --check # LAN raw socket
`--check` prints the `*IDN?` identity and the detected command family.
Claude Code
claude mcp add scope -- uvx labmcp-rigol-scope --address TCPIP0::192.168.1.50::INSTR
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "scope": { "command": "uvx", "args": ["labmcp-rigol-scope", "--address", "TCPIP0::192.168.1.50::INSTR"] } } }
Add --read-only to allow reading settings, measurements, waveforms and screenshots while blocking every tool that changes the scope setup. For other clients, generate the snippet with uvx labmcp config rigol-oscilloscope --address TCPIP0::192.168.1.50::INSTR --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
autoscale | 🎛 control | Run the scope's automatic setup (AUTO key): it picks vertical scales, timebase and trigger for the connected signals. This overwrites the user's current setup - only use it when asked. Needs signals of roughly >20 mVpp and >40 Hz. |
capture_waveform | 👁 read | Capture a channel's waveform, scaled to volts and seconds with the scope's waveform preamble, and return statistics plus a downsampled trace; optionally save all points to CSV. |
force_trigger | 🎛 control | Force one trigger (FORCE key). Only has an effect in NORMal or SINGle sweep while waiting. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Identify the oscilloscope (model, serial, firmware), the command family used for it, the number of analog channels, and the current sample rate and memory depth. |
get_settings | 👁 read | Read the current vertical settings of every channel (on/off, V/div, offset, coupling, probe ratio, bandwidth limit), the timebase, the trigger (type, sweep, status, edge source/level/slope) and the acquisition sample rate / memory depth. |
measure | 👁 read | Read the scope's automatic measurements for one channel: voltages (Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, overshoot, preshoot) and timing (period, frequency, rise/fall time, +/- width, +/- duty). Values the scope cannot determine are null. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
run | 🎛 control | Start continuous acquisition (RUN). |
screenshot | 👁 read | Save a screenshot of the oscilloscope display (PNG; BMP on the MSO5000) and return its path. For PNG screenshots the image is also returned so the model can look at the screen. |
set_channel | 🎛 control | Change a channel's vertical settings; unspecified settings are left alone. The probe ratio is applied first because it changes the valid scale range. Returns the settings the scope actually applied (the scale snaps to 1-2-5 steps). Rejected values are reported from the scope's error queue. |
set_timebase | 🎛 control | Set the main timebase scale and/or offset. Returns the applied values. |
set_trigger | 🎛 control | Configure an edge trigger (source, level, slope) and the sweep mode. Sets the trigger type to EDGE. The level must lie within the source channel's screen range. |
single | 🎛 control | Arm a single acquisition (SINGLE key): the scope triggers once, then stops. With wait_s > 0 it waits until the acquisition is complete (status STOP). If the trigger condition is never met the status stays WAIT - check the trigger level/source or use force_trigger. |
stop | 🎛 control | Stop acquisition (STOP) and freeze the current waveforms, e.g. before reading deep memory. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log shows every SCPI command sent.
| Limit | Default | Meaning |
|---|---|---|
max_memory_points | 1 200 000 points | Most points read from acquisition memory in one capture (bounds transfer time) |
Override at launch, e.g. --limit max_memory_points=24000000. An oscilloscope does not source energy, so there are no hazard tools; this server does not control the built-in waveform generator some models have.
:TRIGger:EDGE:LEVel, :MEASure:ITEM? VPP,CHANnel1, :WAVeform:PREamble?). The differences are taken from each guide: autoscale is :AUToscale (DS1000Z, MSO5000) or :AUToset (DHO); screenshots are :DISPlay:DATA? ON,OFF,PNG (DS1000Z), :DISPlay:DATA? PNG (DHO) or :DISPlay:DATA? → BMP (MSO5000); screen captures return 1200 points (DS1000Z, 12 divisions) or 1000 (MSO5000/DHO, 10 divisions). The family is detected from *IDN?; unknown Rigol models are refused unless you force --option profile=DS1000Z|MSO5000|DHO.:WAVeform:PREamble? and BYTE format: volts = (byte − YORigin − YREFerence) × YINCrement. WORD format is not used because the DHO guides do not document its byte order. For the 12-bit DHO scopes this means 8-bit screen/memory data.mode="memory") follows the documented RAW procedure: stop the scope, then read in batches of 250 000 points with :WAVeform:STARt/STOP (the DS1000Z maximum for BYTE). The MSO5000 and DHO guides document batched reads but not a maximum; the server checks every batch length and fails clearly if a batch comes back short. *Not yet verified on MSO5000/DHO hardware.*clipped_fraction counts points at the ADC limits (codes 0/255) in both modes. The returned trace keeps each block's minimum and maximum sample, so narrow glitches survive downsampling. save_path (CSV) and the screenshot save_path (.png, .bmp on the MSO5000) must be new files: they are checked before anything is read, and existing files are never overwritten.null when the scope answers 9.9E37 (cannot measure). Duty cycle and overshoot are reported exactly as the scope returns them (the DS1000Z guide defines duty as a ratio).:SYSTem:ERRor? afterwards, so an out-of-range scale, offset or trigger level is reported instead of silently ignored. The scale snaps to 1-2-5 steps unless fine adjustment (VERNier) is on.TCPIP0:: ::INSTR). Rigol scopes also accept raw SCPI on TCP port 5555 (tcp:// :5555); that port is widely used but not stated in these guides.libusb for pyvisa-py; pyusb is installed with this package.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |