Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server for Sartorius laboratory balances (SBI protocol).
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"labmcp-sartorius": {
"command": "uvx",
"args": [
"labmcp-sartorius"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add labmcp-sartorius --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-sartorius运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"labmcp-sartorius": {
"command": "uvx",
"args": [
"labmcp-sartorius"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"labmcp-sartorius": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-sartorius"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月9日
注册名称已通过 GitHub 账户 K-Dense-AI 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.1.2)于44天前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, MCP Tennis Match Data
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:↓ 每周下载量i★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
ATP and WTA match results, schedules, and rankings by date
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
Let an AI agent weigh samples, tare containers, log drift and evaporation, and run internal adjustments on Sartorius laboratory balances through the documented SBI (Sartorius Balance Interface) ASCII protocol.
| Package | labmcp-sartorius |
| Instruments | Cubis MSE, Cubis II MCA, Secura, Quintix, Practum, Entris II; older CP/CPA-series balances with --option legacy=true. Other SBI balances are likely to work |
| Interfaces | RS-232, USB (virtual COM port, "PC-SBI"), Ethernet (Cubis II "serial transmission via Ethernet", or any serial-to-Ethernet adapter) |
| Protocol | SBI: Entris II interface description (technical note 10/2020), Secura/Quintix/Practum user manual §10.3 (WSE6004), Cubis MSE operating instructions (WMS6004), Cubis MCA operating instructions (WMC6028), SBI interface description (98647-000-53) |
| Status | 🧪 simulated: tested against a wire-level SBI simulator, not yet verified on hardware. Report a hardware test |
uvx labmcp-sartorius --simulate --check
ESC P toggles the automatic output instead of sending one reading. Either line format works (16 characters, or 22 with ID code).?rtscts=true to enforce it, or e.g. ?bytesize=7&parity=E if your balance is set differently.uvx labmcp ports uvx labmcp-sartorius --address /dev/ttyUSB0 --check # Linux
uvx labmcp-sartorius --address /dev/tty.usbmodem14201 --check # macOS uvx labmcp-sartorius --address COM4 --check # Windows uvx labmcp-sartorius --address tcp://192.168.1.61:49155 --check # Cubis II via Ethernet (port as configured)
`--check` prints the model, serial number and software version (`ESC x1_`, `x2_`, `x3_`) when the balance supports them.
Claude Code
claude mcp add balance -- uvx labmcp-sartorius --address /dev/ttyUSB0
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "balance": { "command": "uvx", "args": ["labmcp-sartorius", "--address", "/dev/ttyUSB0"] } } }
Add --read-only to allow weighing but block taring, zeroing and adjustment. For other clients: uvx labmcp config sartorius-balance --address /dev/ttyUSB0 --client vscode.
| Tool | Kind | Description |
|---|---|---|
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
lock_keypad | 🎛 control | Block or unblock the balance keys, e.g. so nobody tares by accident during a long logging run. |
log_weight_series | 👁 read | Record a series of immediate (unfiltered) readings to monitor drift, evaporation, moisture uptake or stabilisation. Returns every reading plus summary statistics. |
read_weight | 👁 read | Read the current net weight from the balance (ESC P). With stable=True the server polls until the balance reports a stable value; if it cannot settle (draughts, vibration, evaporation) you get an error; retry, or use stable=false for the current value. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
run_internal_adjustment | 🎛 control | Adjust (calibrate) the balance with its built-in weight (ESC Z; isoCAL models only). The pan must be empty and the balance undisturbed. SBI sends no completion message, so the server watches for the adjustment status and waits until the balance weighs again; check observed_adjustment and the balance display or GLP printout for the result. |
set_ambient_conditions | 🎛 control | Adapt the balance's filter to the ambient conditions (ESC K/L/M/N). Use 'unstable' or 'very_unstable' for draughty or vibrating benches (slower but steadier readings). |
tare | 🎛 control | Tare the balance (ESC U, or ESC T on legacy balances): the current load (e.g. an empty container) becomes the tare. Then waits for a stable reading and checks that it is ~0; returns that reading. |
zero | 🎛 control | Zero the balance (ESC V). Only works with the pan (nearly) empty, within the balance's zero-setting range; clears the tare. Confirms by reading ~0 afterwards. |
| Limit | Default | Meaning |
|---|---|---|
max_series_duration_s | 600 s | Longest weight-logging series an agent may start |
Override at launch: --limit max_series_duration_s=3600. Whatever the limit says, a single series is capped at one hour (the tool's time limit). No tool of this server moves anything or heats, so there are no hazard tools.
read_weight(stable=true) therefore polls ESC P until a reading with a unit arrives. Unstable readings report the last unit seen.N, G#, T, Stat, then the same 16). It also accepts the Cubis II "one line with full length" format, a decimal comma, and a G#/T/N weighing block (the N line is reported). High, Low, Err ###, APP.ERR, DIS.ERR and PRT.ERR are reported as clear errors.ESC U tare, ESC V zero, ESC Z adjust, ESC K–N filter, ESC O/R keys) produce no reply, so a balance that does not support one silently ignores it. tare and zero therefore wait for a stable reading and check it is ~0, and report an error otherwise.ESC V only zeroes within the balance's zero-setting range (nearly empty pan); ESC U tares any load. Older balances (CP/CPA, LE, ...) only have ESC T (the tare key): start the server with --option legacy=true.ESC Z starts isoCAL on balances with a built-in weight. SBI sends no completion or result message; the server watches for the Cal. status (or a balance too busy to answer) and waits for a stable weight again, and reports observed_adjustment=false if it never sees one. Confirm the result on the display or GLP printout. The exact status output during adjustment could not be verified in the manuals.ESC x1_/x2_/x3_ print the model, serial number and software version; their exact layout is not documented, so the text is passed through as sent.1b 50 0d 0a = ESC P CR LF) because of the ESC character.ESC W, needs a reference weight), ESC S restart and the function-key commands.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |