Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
MCP server for Motor Current Signature Analysis — fault detection in electric motors
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"mcsa": {
"command": "uvx",
"args": [
"mcp-server-mcsa"
]
}
}
}在终端中运行这条命令
claude mcp add mcsa -- uvx mcp-server-mcsa粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"mcsa": {
"command": "uvx",
"args": [
"mcp-server-mcsa"
]
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"mcsa": {
"type": "stdio",
"command": "uvx",
"args": [
"mcp-server-mcsa"
]
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月7日
注册名称已通过 GitHub 账户 LGDiMaggio 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.2.1)于9个月前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, Aiterm MCP
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Persistent terminals and one launcher for Claude, Codex, Grok, Cursor, and Antigravity harnesses.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
A Model Context Protocol (MCP) server for Motor Current Signature Analysis (MCSA) — non-invasive spectral analysis and fault detection in electric motors using stator-current signals.
mcp-server-mcsa turns any LLM into a predictive-maintenance expert. By integrating advanced techniques such as Fast Fourier Transform (FFT) and envelope analysis, the system can *listen* to a motor's electrical signature and automatically identify mechanical and electrical anomalies — all through natural language.
MCSA is an industry-standard condition-monitoring technique that analyses the harmonic content of the stator current to detect rotor, stator, bearing, and air-gap faults in electric motors — without requiring vibration sensors, downtime, or physical access to the machine. This server brings the full MCSA diagnostic workflow to any MCP-compatible AI assistant (Claude Desktop, VS Code Copilot, and others), enabling both interactive expert analysis and automated condition-monitoring pipelines.
.npy files~/.mcsa_data/ as compressed .npz files; referenced by short IDs (sig_xxxx, spec_xxxx) to keep large arrays out of the chat context; data survives server restarts| Tool | Description |
|---|---|
inspect_signal_file | Inspect a signal file format and metadata without loading |
load_signal_from_file | Load a current signal from CSV / WAV / NPY file → returns signal_id |
calculate_motor_params | Compute slip, sync speed, rotor frequency from motor data |
compute_fault_frequencies | Calculate expected fault frequencies for all common fault types |
compute_bearing_frequencies | Calculate BPFO, BPFI, BSF, FTF from bearing geometry |
preprocess_signal | DC removal, filtering, normalisation, windowing pipeline → returns new signal_id |
compute_spectrum | Single-sided FFT amplitude spectrum → returns spectrum_id |
compute_power_spectral_density | Welch PSD estimation → returns spectrum_id |
find_spectrum_peaks | Detect and characterise peaks in a spectrum |
detect_broken_rotor_bars | BRB fault index with severity classification |
detect_eccentricity | Air-gap eccentricity detection via sidebands |
detect_stator_faults | Stator inter-turn short circuit detection |
detect_bearing_faults | Bearing defect detection from current spectrum |
compute_envelope_spectrum | Hilbert envelope spectrum for modulation analysis |
compute_band_energy | Integrated spectral energy in a frequency band |
compute_time_frequency | STFT analysis with optional frequency tracking |
generate_test_current_signal | Synthetic motor current with optional faults → returns signal_id |
run_full_diagnosis | Complete MCSA diagnostic pipeline from signal or signal_id |
diagnose_from_file | Complete MCSA diagnostic pipeline directly from file |
list_stored_data | List all signals and spectra persisted on disk |
clear_stored_data | Delete one or all stored items from disk |
| URI | Description |
|---|---|
mcsa://fault-signatures | Reference table of fault signatures, frequencies, and empirical thresholds |
| Prompt | Description |
|---|---|
analyze_motor_current | Step-by-step guided workflow for MCSA analysis |
uv is the recommended Python package manager. It handles everything (Python, packages, virtual environments) in a single tool and is used throughout the MCP ecosystem.
Windows (PowerShell):
powershell -ExecutionPolicy ByPass -c "irm https://astral.sh/uv/install.ps1 | iex"
macOS / Linux:
curl -LsSf https://astral.sh/uv/install.sh | sh
After installing, restart your terminal so the
uv/uvxcommands are available.
uvx mcp-server-mcsa --help
You should see the help text. That's it — no pip install needed. uvx downloads and runs the package automatically in an isolated environment.
Pick your client and add the configuration below. No other steps are required.
Open the config file:
%APPDATA%\Claude\claude_desktop_config.json~/Library/Application Support/Claude/claude_desktop_config.jsonAdd mcsa inside the mcpServers object (create the file if it doesn't exist):
{
"mcpServers": { "mcsa": { "command": "uvx", "args": ["mcp-server-mcsa"] } } }
Then restart Claude Desktop.
Create (or edit) .vscode/mcp.json in your workspace:
{
"servers": { "mcsa": { "command": "uvx", "args": ["mcp-server-mcsa"] } } }
Go to Settings → MCP Servers → Add new server:
commanduvx mcp-server-mcsaIn your MCP client, try:
"Generate a test signal with a broken rotor bar fault and run a full diagnosis. Motor: 4 poles, 50 Hz, 1470 RPM."
If the server responds with a diagnostic report, you're all set.
Alternative: install with pip (not recommended — see note)
pip install mcp-server-mcsa
Then configure your client with:
{
"mcpServers": { "mcsa": { "command": "python", "args": ["-m", "mcp_server_mcsa"] } } }
⚠️ Common issue on Windows: if you installed Python from the Microsoft Store, the
mcp-server-mcsacommand may not be in your PATH, causing a "server disconnected" error. In that case, find your Python path withpython -c "import sys; print(sys.executable)"and use the full path in the config:
`json
{
"mcpServers": {
"mcsa": {
"command": "C:/Users/YOU/AppData/Local/.../python.exe",
"args": ["-m", "mcp_server_mcsa"]
}
}
}
`
Using
uvxavoids this problem entirely.
Alternative: install from source (for development)
git clone https://github.com/LGDiMaggio/mcp-motor-current-signature-analysis.git
cd mcp-motor-current-signature-analysis uv sync --dev
Configure the client to point to the local repo:
{
"mcpServers": { "mcsa": { "command": "uv", "args": ["--directory", "/absolute/path/to/mcp-motor-current-signature-analysis", "run", "mcp-server-mcsa"] } } }
Run tests:
uv run pytest
Debug with MCP Inspector:
uv run mcp dev src/mcp_server_mcsa/server.py
| Problem | Fix |
|---|---|
| "server disconnected" on Claude Desktop | Check the logs at %APPDATA%\Claude\logs\ (Windows) or ~/Library/Logs/Claude/ (macOS). Most common cause: the command in the config is not found. Use uvx to avoid PATH issues. |
uvx: command not found | Restart your terminal after installing uv. On Windows, you may need to close and reopen PowerShell. |
mcp-server-mcsa: command not found (pip) | The script wasn't added to PATH. Use python -m mcp_server_mcsa instead, or switch to uvx. |
| Server starts but tools don't appear | Make sure you restarted the MCP client after editing the config. |
Signals and spectra are persisted to disk as compressed .npz files in ~/.mcsa_data/ (configurable via the MCSA_DATA_DIR environment variable). This means:
sig_xxxx, spec_xxxx) and compact summaries are returned to the LLM.~/.mcsa_data/
signals/ sig_a1b2c3d4.npz ← loaded from CSV sig_e5f6g7h8.npz ← generated test signal spectra/ spec_i9j0k1l2.npz ← FFT result
Use list_stored_data to see everything on disk and clear_stored_data to remove items.
The fastest way to analyse a measured signal is the diagnose_from_file tool. Simply provide the file path and motor nameplate data:
"Diagnose the motor from
C:\data\motor_phaseA.csv— 50 Hz supply,
4 poles, 1470 RPM"
The server loads the file, preprocesses the signal, computes the spectrum, runs all fault detectors, and returns a complete JSON report with severity-classified results.
"Load the signal from
measurement.wav" → returnssignal_id: sig_a1b2
or: "Generate a test signal with a broken-rotor-bar fault" →
sig_c3d4
"Calculate motor parameters for a 4-pole motor, 50 Hz supply, running at 1470 RPM"
"What are the expected fault frequencies for this motor?"
"Preprocess signal sig_a1b2" → returns new
signal_id: sig_e5f6
"Compute the FFT spectrum of sig_e5f6" → returns
spectrum_id: spec_g7h8
"Check for broken rotor bars in spec_g7h8"
"Compute the envelope spectrum of sig_e5f6"
The run_full_diagnosis tool runs the entire pipeline on a stored signal in a single call:
Input: signal_id + motor nameplate data
Output: complete report with fault severities and recommendations
For bearing fault analysis, you need the bearing geometry (number of balls, ball diameter, pitch diameter, contact angle). The server will:
| Format | Extensions | Sampling Rate |
|---|---|---|
| CSV / TSV | .csv, .tsv, .txt | From time column or user-supplied |
| WAV | .wav | Embedded in header |
| NumPy | .npy | User-supplied |
Sidebands at $(1 \pm 2s) \cdot f_s$ where $s$ is slip and $f_s$ is supply frequency. Severity is classified by the dB ratio of sideband to fundamental amplitude.
只显示了开头部分;其余内容请在仓库中阅读