Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
Let AI configure telecom gear over serial: Juniper and Cisco, Icom CI-V, Yaesu/Kenwood CAT, rotators
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"serial-console": {
"command": "uvx",
"args": [
"serial-console-mcp"
]
}
}
}在终端中运行这条命令
claude mcp add serial-console -- uvx serial-console-mcp粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"serial-console": {
"command": "uvx",
"args": [
"serial-console-mcp"
]
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"serial-console": {
"type": "stdio",
"command": "uvx",
"args": [
"serial-console-mcp"
]
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月8日
注册名称已通过 GitHub 账户 sbrunner-atx 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(0.3.2)于2个月前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, Brontide agent arena
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:↓ 每周下载量i★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
THE MECH ARENA BUILT FOR AI AGENTS. HUMANS WELCOME. Pilot mech duels over MCP, free, no sign-in.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
AI for the configuration of telecommunication equipment, through the console port it already has.
MIT licensed · Python 3.10+ · status: 0.3.2, verified live on a Juniper EX2200 console
serial-console-mcp connects an AI assistant such as Claude to the serial console of the equipment that runs networks and radio stations, and of anything else with a serial port:
commit confirmed on Junos, reload in on IOS), and leave the console as it was found.You say what you want in plain language. The assistant drives the console through this server, Claude Desktop asks you to approve each step, and bundled operating skills teach it the Junos and IOS basics: which mode a prompt means, how to get in and out, which show commands answer everyday questions.
Juniper support is verified on a real EX2200 console. Cisco, CI-V, CAT and rotator support follows the vendors' protocol references and has not yet met hardware on this bench. The other device types use the generic tools rather than device-specific helpers.
You do not need to know any programming. After it's installed you talk to Claude normally:
You: What serial ports do you see?
Claude: I found two. One looks like a Silicon Labs CP210x on COM4 — that's
probably your device.
You: Connect to COM4 at 9600 baud.
Claude: Connected.
You: Log in and show me the version.
A serial console isn't a simple question-and-answer channel. It echoes what you type, prints unsolicited messages on its own (logs, interface flaps), and can dump pages of output. So the moment a port is open, a background reader keeps draining it into a buffer. That means Claude can:
# , > , login: …) to capture the whole reply — even a long one — without cutting it off, orThis is the same model minicom and expect use, which is why it handles interactive CLIs properly.
| Tool | What it does |
|---|---|
list_serial_ports | Enumerate ports with description and USB hardware id; marks ones open here |
list_presets | Usual settings per device family: Cisco/Juniper/Linux consoles, full-screen consoles (BIOS, BMC, menus), Kenwood/Elecraft/Yaesu CAT, Icom and Xiegu CI-V, rotators, Arduino, NMEA GPS |
connect / reconnect_last / disconnect | Open a port by name. Defaults 9600 8N1, no flow control; baud, data bits, parity, stop bits, RTS/CTS, XON/XOFF, line ending and prompt are all settable, or loaded from a preset. Several ports at once |
send_keys / screen | Press Ctrl-C, Esc, Tab, arrows, F-keys by name; view the VT100/xterm screen of a full-screen console (BIOS, BMC, menu switches, vi) |
send_text / send_hex | Write an ASCII line (CR / LF / CRLF / none) or raw hex bytes. Write-only |
read_until_prompt | Return buffered output up to a literal or regex prompt, leaving the rest; auto_reply pages through --More-- |
read_available | Return whatever has arrived, as text and hex |
query_text | Clear, send, then read until the prompt or until the line goes idle |
expect | A scripted list of send-and-wait steps in one call: logins, command sequences |
set_lines / pulse_line / send_break | Drive DTR and RTS (PTT, Arduino reset), send BREAK |
capture_start / capture_stop / get_transcript | Log a session to a file (raw or timestamped TX/RX); re-read the rolling transcript |
port_in_use_by / detect_baud | Which program holds a port; which baud rate produces readable text |
cat_build / cat_parse | Kenwood, Elecraft and Yaesu ; commands: build a frequency set, decode ID, FA, MD, IF and error replies |
civ_build / civ_parse / civ_freq | Icom CI-V frames: build, decode (echo vs reply, BCD frequency, mode, PTT), convert |
rotator_build / rotator_parse | GS-232 rotator commands (read, move, stop, speed) and position replies |
clear_buffer / status | Housekeeping; status shows every open port with control-line states |
Ports are opened by name ("rig", "rotator"); tools default to the most recently used one. Each connection has a terminal mode: dumb (raw bytes, the default), ansi (colours and escape sequences stripped, CR/backspace overwrites applied, prompts matched on the line as displayed even after a device redraws it with spaces and backspaces; used by the console presets), or xterm/vt100 (a real screen you can read with screen; needs pip install 'serial-console-mcp[screen]', included in the desktop extension). The receive buffer is capped at 4 MB per port; if a device streams for hours unread, the oldest bytes are dropped and status says how many.
Three skill files in skills/ teach an agent the discipline, the way the fldigi-mcp skills do; copy them into ~/.claude/skills/ or a project's .claude/skills/:
| Skill | What it teaches | |
|---|---|---|
serial-console | The console model, the six rules, terminal modes, keys, presets | |
junos-operating | Junos modes from the prompt (% shell, > operational, # configure), out of the BSD shell and back, configure exclusive, `show \ | compare, commit confirmed, rollback, cli -c and start shell, health and interface show commands verified on an EX2200 (show chassis routing-engine, show interfaces terse/brief`) |
ios-operating | IOS modes (>, #, (config)#), enable/configure terminal/end, reload in 10 as the safety net, write memory, everyday show commands (show ip interface brief, show processes cpu sorted) |
| Variable | Effect |
|---|---|
SERIAL_CONSOLE_READ_ONLY=1 | Refuse writes except read-style commands (show, ID;, CI-V reads) and refuse control-line changes |
SERIAL_CONSOLE_ALLOW= | Override the read-only allowlist |
SERIAL_CONSOLE_IDLE_MINUTES=15 | Auto-close a port idle that long (default: never) |
Set them in the server's entry in claude_desktop_config.json under "env".
serial-console-mcp.mcpb from the Releases page. The same file works on Mac, Windows and Linux.No terminal, no Python, nothing to configure by hand.
Upgrading from the 0.3.x `.pkg` or `.exe` installer? Remove the old copy first, or Claude Desktop starts two servers. On a Mac:
"/Library/Application Support/SerialConsoleMCP/serial-console-mcp" configure --remove
sudo rm -rf "/Library/Application Support/SerialConsoleMCP"
On Windows, uninstall Serial Console MCP under Settings → Apps. Then quit and reopen Claude Desktop.
If you already have Python 3.10+ and uv or pipx, you can skip the extension:
uvx serial-console-mcp --version # fetches and runs it
uvx serial-console-mcp configure --command uvx --arg serial-console-mcp
or
pipx install serial-console-mcp
serial-console-mcp configure --command "$(which serial-console-mcp)"
configure writes a serial-console entry into claude_desktop_config.json (merging with whatever is already there and backing the old file up first). Quit and reopen Claude Desktop. serial-console-mcp configure --remove undoes it. Any other MCP client can launch the same command over stdio.
git clone https://github.com/sbrunner-atx/serial-console-mcp.git
cd serial-console-mcp uv sync # or: python3 -m venv .venv && . .venv/bin/activate && pip install -e . pytest uv run pytest # fake serial port, no hardware needed uv run serial-console-mcp configure --command "$PWD/.venv/bin/serial-console-mcp"
The package lives in src/serial_console_mcp/: server.py is the MCP server, configure.py the Claude Desktop registrar. manifest.json describes the desktop extension; npx @anthropic-ai/mcpb pack builds it. BUILD.md covers the retired .pkg and .exe installers.
Plain-English requests work. Some examples:
expect call: return, login, password, command).detect_baud).pulse_line("RTS", 2000), after you confirm).civ_build, send_hex, read_available, civ_parse).query_text("FA;"), cat_parse).rotator_build, query_text, rotator_parse).send_keys)screen-console preset, screen, send_keys)show interfaces terse, then show me all of it."For a router/switch console, tell Claude the prompt it should wait for (often # for enable mode or > for user mode) and it will read until it sees it. For an Icom radio (CI-V), tell Claude — it can send the hex commands those radios expect.
"No serial ports found."
"Could not open the port" / "access denied."
Claude says it can't access serial ports at all.
只显示了开头部分;其余内容请在仓库中阅读