Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者提供的说明(英文原文)
VMware vSphere storage with 16 MCP tools: datastores, iSCSI, vSAN, FC multipath.
这三项永远不会合并成一个分数:意见、测量和人气是不同的东西。
我们还没有为它写通俗的介绍。下面是我们从注册中心读取到的事实。
选择你使用的 AI 应用,然后复制设置。
VMWARE_STORAGE_CONFIG你需要
你用的是哪个应用?
在上方选择你的应用。我们会记住它,下次按钮会显示“安装到 …”。
打开 Claude Desktop → Settings → Developer → Edit Config,把下面的内容粘贴到 claude_desktop_config.json
{
"mcpServers": {
"vmware-storage": {
"command": "uvx",
"args": [
"vmware-storage",
"mcp"
],
"env": {
"VMWARE_STORAGE_CONFIG": "your-value"
}
}
}
}在终端中运行这条命令
claude mcp add vmware-storage --env VMWARE_STORAGE_CONFIG=your-value -- uvx vmware-storage mcp运行前请先填写空着的值。
粘贴到项目中的 .cursor/mcp.json,或 ~/.cursor/mcp.json
{
"mcpServers": {
"vmware-storage": {
"command": "uvx",
"args": [
"vmware-storage",
"mcp"
],
"env": {
"VMWARE_STORAGE_CONFIG": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
粘贴到项目中的 .vscode/mcp.json
{
"servers": {
"vmware-storage": {
"type": "stdio",
"command": "uvx",
"args": [
"vmware-storage",
"mcp"
],
"env": {
"VMWARE_STORAGE_CONFIG": "your-value"
}
}
}
}浏览器会先询问是否打开应用,然后应用会显示设置并请你确认。密钥的值会留空,由你自己填写。
这个服务器在你的电脑上运行,而 ChatGPT 只能连接互联网上的服务器。请选择其他应用。
你的选择通过 Cookie 保存在这台设备上,无需账户。
VMWARE_STORAGE_CONFIG env这些设置是根据作者在注册中心的条目生成的。如果 README 的写法不同,请以 README 为准。
它在你的电脑上运行;安装后,工具列表会显示在你的 AI 应用中。
我们检查的是任何人都能看到的信息;我们没有阅读代码。不适用的检查项不计入总数。 · 检查于 2026年11月7日
注册名称已通过 GitHub 账户 vmware-skills 验证,该账户拥有此仓库
我们还没有从 GitHub 读取这个仓库
我们还没有从 GitHub 读取这个仓库
它在你的电脑上运行,没有互联网端点
在你的电脑上运行,改用本地设置
它在你的电脑上运行;我们只能读取互联网端点的工具列表
与注册中心里这个分类中所有活跃的服务器比较。只有当发布者拥有该仓库时,星标数才计入。
它在 1 项适用的基础检查中通过了 1 项。我们没有阅读代码。在添加密钥或令牌之前,请先看看这个服务器要求哪些权限,并使用只具备所需权限的密钥。
注册中心没有列出必需的密钥,不过有些服务器会在首次使用时要求你登录。
它在你的电脑上运行。你的 AI 应用会在需要时启动它,数据不会经过作者的服务器(除非它自己调用在线服务)。
GitHub 仓库最后更新于–,最新版本(2.5.0)于6天前进入注册中心。
支持 MCP 的应用,例如 Claude Desktop、Claude Code、Cursor 和 VS Code。你的电脑上还需要有 Python (uv)。
同一分类中有:Spec Driven Development, Remote Desktop Commander, Georgia MCP
同一分类中其他作者的服务器,按星标数排序。
如何看卡片:★ GitHub 星标i三大支柱:评价 · 检查 · 使用情况i更新 = 最新版本发布到注册中心的时间i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
An MCP server for Georgian public data, read from the organizations that publish it.
按原文从作者的仓库复制。PopNx MCP 没有审查或背书其内容。HTML、图片和脚本已被移除。链接会离开本站。
For a read-only check of this skill with your model and agent host, use the shared model-fit self-test in the marketplace root.
Author: Wei Zhou, VMware by Broadcom — wei-wz.zhou@broadcom.com
This is a community-driven project by a VMware engineer, not an official VMware product.
For official VMware developer tools see developer.broadcom.com.
English | 中文
VMware vSphere storage management: datastores, iSCSI, vSAN, and read-only Fibre Channel / multipath diagnostics — 16 MCP tools, domain-focused and lightweight.
Split from vmware-aiops for lighter context and local model compatibility.
2.0 renames 10 of its MCP tools (all but the four that already started with a verb) so every name starts with a verb (e.g. fc_adapter_list → list_fc_adapters, storage_device_paths → list_storage_device_paths, storage_iscsi_add_target → add_iscsi_target). The full old → new table is in RELEASE_NOTES.md. Three tools also change a parameter: browse_datastore and scan_datastore_images take datastore_name (was ds_name, now the same as vmware-aiops' browse_datastore), and list_all_datastores gains an optional limit (same as vmware-monitor's). Everything else stays: same tools, safety gates and CLI commands (the CLI still takes the datastore name as before). If an agent prompt, script or ~/.vmware/rules.yaml names a tool, update it — though deny rules written with the old names keep working with vmware-policy ≥ 1.18 (vmware-audit policy lists any rule the renames widened), and vmware-pilot ≥ 1.13 translates old names in saved workflows. If an install older than 2.0 shares that rules.yaml, give it vmware-policy ≥ 1.18.2 too: it matches each rule against both the old and the new name, so one file serves both.
| Skill | Scope | Tools | Install |
|---|---|---|---|
| [vmware-aiops](https://github.com/vmware-skills/VMware-AIops) ⭐ entry point | VM lifecycle, deployment, guest ops, clusters | 49 | uv tool install vmware-aiops |
| [vmware-monitor](https://github.com/vmware-skills/VMware-Monitor) | Read-only monitoring, alarms, events, VM info | 27 | uv tool install vmware-monitor |
| [vmware-vks](https://github.com/vmware-skills/VMware-VKS) | Tanzu Namespaces, TKC cluster lifecycle | 20 | uv tool install vmware-vks |
| [vmware-nsx](https://github.com/vmware-skills/VMware-NSX) | NSX networking: segments, gateways, NAT, IPAM | 33 | uv tool install vmware-nsx-mgmt |
| [vmware-nsx-security](https://github.com/vmware-skills/VMware-NSX-Security) | DFW microsegmentation, security groups, Traceflow | 21 | uv tool install vmware-nsx-security |
| [vmware-aria](https://github.com/vmware-skills/VMware-Aria) | Aria Ops metrics, alerts, capacity planning | 28 | uv tool install vmware-aria |
# Via PyPI
uv tool install vmware-storage
pip install vmware-storage
This project uses the modern PEP 517 build system (hatchling), so there is no `setup.py` by design — that is expected, not a missing file. If you cloned the source and hit ERROR: File "setup.py" or "setup.cfg" not found ... editable mode currently requires a setuptools-based build, your pip is older than 21.3 and cannot do an *editable* (-e) install with a non-setuptools backend. Editable mode is a developer convenience, not needed to run the tool — do one of:
# From the source tree — a normal (non-editable) install builds a wheel:
pip install . # NOT pip install -e .
pip install --upgrade pip && pip install -e .
For a truly air-gapped host, build the wheels on a connected machine and copy them over — the target then needs no network:
# On a connected machine, collect this package + its dependencies as wheels:
pip wheel . -w dist # → dist/*.whl (or: uv build, for just this package)
pip install --no-index --find-links dist vmware-storage
mkdir -p ~/.vmware-storage
cp config.example.yaml ~/.vmware-storage/config.yaml
echo "VMWARE_MY_VCENTER_PASSWORD=your_password" > ~/.vmware-storage/.env chmod 600 ~/.vmware-storage/.env
vmware-storage doctor
| Category | Tools | Type |
|---|---|---|
| Datastore | list_all_datastores, get_datastore_vm_usage, browse_datastore, scan_datastore_images, list_cached_images | Read |
| iSCSI | enable_iscsi, get_iscsi_status, add_iscsi_target, remove_iscsi_target, rescan_storage | Read/Write |
| vSAN | get_vsan_health, get_vsan_capacity, get_vsan_efficiency | Read |
| FC / multipath | list_fc_adapters, list_storage_device_paths | Read |
| Access | get_access_info — which account the server uses and whether it holds each tool's vSphere privileges (root folder) | Read |
The patterns/ directory hosts L5 auto-remediation candidate patterns from the Enterprise Harness Engineering framework. The first PoC pattern, patterns/iscsi-target-stale-rescan.yaml, describes an iSCSI HBA rescan as a low-risk, reversible, repeatable operation. The pattern schema is documented here only — runtime enforcement is not yet wired up, so this is a reference design, not production auto-remediation.
vmware-storage iscsi enable esxi-01vmware-storage iscsi add-target esxi-01 10.0.0.100vmware-storage iscsi status esxi-01The add-target command automatically rescans storage. Use --dry-run to preview any write command first.
vmware-storage datastore listvmware-storage datastore scan-images datastore01vmware-storage datastore browse datastore01 --pattern "*.iso"vmware-storage vsan health Cluster-Prodvmware-storage vsan capacity Cluster-Prodvmware-monitor for alarms and eventsvmware-storage paths devices --datastore ds-fc-01vmware-storage paths devices --cluster Cluster-Prod --only-differencesvmware-storage paths fc-adapters --cluster Cluster-ProdHosts that could not be read are listed in hosts_not_read and are never reported as missing a device. Path states are reported as vSphere reports them — standby is not flagged.
# Datastore
vmware-storage datastore list vmware-storage datastore browse datastore01 vmware-storage datastore scan-images datastore01
vmware-storage iscsi status esxi-01 vmware-storage iscsi enable esxi-01 vmware-storage iscsi add-target esxi-01 192.168.1.100 vmware-storage iscsi remove-target esxi-01 192.168.1.100 vmware-storage iscsi rescan esxi-01
vmware-storage vsan health Cluster-Prod vmware-storage vsan capacity Cluster-Prod
vmware-storage paths fc-adapters --cluster Cluster-Prod vmware-storage paths devices --datastore ds-fc-01
vmware-storage doctor
After `uv tool install vmware-storage`, start the MCP server with one command (v1.5.15+):
# Recommended — single command, no network re-resolve
vmware-storage mcp
VMWARE_STORAGE_CONFIG=/path/to/config.yaml vmware-storage mcp
docker compose up -d
Add to your AI agent's MCP config:
{
"mcpServers": { "vmware-storage": { "command": "vmware-storage", "args": ["mcp"], "env": { "VMWARE_STORAGE_CONFIG": "~/.vmware-storage/config.yaml" } } } }
Alternative: uvx (no install) or legacy entry point
# Run without installing (requires PyPI access each launch)
uvx --from vmware-storage vmware-storage mcp
vmware-storage-mcp
Behind a corporate TLS proxy? uvx may fail with
invalid peer certificate: UnknownIssuer.
Use the recommended
vmware-storage mcpform above (no network needed), or setUV_NATIVE_TLS=true.
vmware-aiops has 61 MCP tools — too heavy for local LLMs (7B-14B). By splitting storage into its own skill:
Python: 3.10+ (since v1.5.27 — previously 3.11+). Tested on 3.10 / 3.11 / 3.12.
| vSphere / VCF | Support | Notes |
|---|---|---|
| VCF 9.1 / vSphere 9.1 | Full | Released 2026-05-12. pyVmomi+vSAN SDK <10.0 works via SOAP. |
| VCF 9.0 / vSphere 9.0 | Full | pyVmomi 8.0.3+ with bundled vSAN SDK connects to vSphere 9. |
| 8.0 | Full | vSAN SDK built into pyVmomi 8.0.3+ |
| 7.0 | Full | All storage APIs work |
| 6.7 | Compatible | iSCSI + datastore features work; vSAN limited |
| Feature | Description |
|---|---|
| Read-heavy | 12/16 tools are read-only |
| Preview by default (MCP) | The 4 write tools take confirm (default false): a call without it changes nothing and returns blast_radius (host, adapters, and for target removal the paths, devices and datastores behind the target). confirm=true is refused when a datastore would lose every path or part of the blast radius could not be read. the old dry_run alias was removed in 2.4.3 and is refused as an unknown argument |
| Input validation | IP addresses and ports validated before iSCSI operations |
| Audit logging | All operations logged to ~/.vmware-storage/audit.log |
| No VM operations | Cannot create, delete, or modify VMs |
| Credential safety | Passwords only from environment variables, never config files |
| Problem | Cause & Fix |
|---|---|
| iSCSI enable fails with "already enabled" | Not an error — adapter is already active. Run iscsi status to see configured targets. |
| "Datastore not found" when browsing | Datastore names are case-sensitive. Run datastore list to get the exact name. |
get_vsan_health returns overall_health: null | null = not asked (see health_not_queried_reason), never a measurement; a string is always vSAN's own answer, including its own "unknown". Usual cause: connected to standalone ESXi, but the health service runs in vCenter. |
| Rescan doesn't discover new LUNs | Wait 15-30 seconds after adding targets, then rescan again. Verify target IP is reachable from ESXi. |
| "Password not found" error | Varia
只显示了开头部分;其余内容请在仓库中阅读