World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
MCP server for Alicat mass flow and pressure meters/controllers.
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 0/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 7/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 7/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install Alicat Mass Flow & Pressure Controller. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-alicat.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Alicat Mass Flow & Pressure Controller for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-alicat": { "command": "uvx", "args": [ "labmcp-alicat" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Alicat Mass Flow & Pressure Controller tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-alicat": {
"command": "uvx",
"args": [
"labmcp-alicat"
]
}
}
}Use Alicat Mass Flow & Pressure Controller and tell me what you can do for me, then show me one thing✓ If Claude says it is using Alicat Mass Flow & Pressure Controller or shows a Alicat Mass Flow & Pressure Controller tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect Alicat Mass Flow & Pressure Controller yet
Alicat Mass Flow & Pressure Controller runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect Alicat Mass Flow & Pressure Controller
B · Others in Other that work with ChatGPT
Picked from the most used in the same category, only ones that connect by address with no key
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Alicat Mass Flow & Pressure Controller for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-alicat -- uvx labmcp-alicat 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Alicat Mass Flow & Pressure Controller tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-alicat -- uvx labmcp-alicatYou should see Alicat Mass Flow & Pressure Controller listed as connected
Use Alicat Mass Flow & Pressure Controller and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using Alicat Mass Flow & Pressure Controller or shows a Alicat Mass Flow & Pressure Controller tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Alicat Mass Flow & Pressure Controller for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-alicat": { "command": "uvx", "args": [ "labmcp-alicat" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Alicat Mass Flow & Pressure Controller tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Alicat Mass Flow & Pressure Controller and tell me what you can do for me, then show me one thing✓ If Cursor says it is using Alicat Mass Flow & Pressure Controller or shows a Alicat Mass Flow & Pressure Controller tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Alicat Mass Flow & Pressure Controller for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-alicat": { "type": "stdio", "command": "uvx", "args": [ "labmcp-alicat" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Alicat Mass Flow & Pressure Controller tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Alicat Mass Flow & Pressure Controller and tell me what you can do for me, then show me one thing✓ If VS Code says it is using Alicat Mass Flow & Pressure Controller or shows a Alicat Mass Flow & Pressure Controller tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-alicat -- uvx labmcp-alicatClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-alicat": {
"command": "uvx",
"args": [
"labmcp-alicat"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-alicat": {
"command": "uvx",
"args": [
"labmcp-alicat"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-alicat": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-alicat"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-alicatBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
No entries on OSV.dev for labmcp-alicat@0.1.2
Checks only this package version, not every dependency · checked Nov 16, 2026
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-alicat)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.2) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
Manage monitors, status pages, incidents and maintenances in your openstatus workspace.
Validate oh-my-posh configurations and segment snippets against the official schema.
MCP server for progressive tool usage at any scale (see https://klavis.ai)
Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.
| This one Alicat Mass Flow & Pressure Controller | World Monitor | openstatus | Oh My Posh Validator | Strata | Jitsu | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install |
| Needs a key | No | No | No | No | No | No |
| Add with + in Claude | No | No | No | No | No | No |
| Basic checks | 3/3 | 4/4 | 4/4 | 4/4 | 1/4 | 4/4 |
| License | Apache-2.0 | AGPL-3.0 | AGPL-3.0 | MIT | Apache-2.0 | MIT |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent read gas flow, pressure and temperature, set flow or pressure setpoints, switch the gas calibration, tare, and hold or close valves on Alicat Scientific mass flow meters and controllers and pressure controllers through Alicat's documented ASCII serial protocol.
| Package | labmcp-alicat |
| Instruments | Mass flow controllers (MC, MCR, MCS, MCE, MCV, MCW, ...), mass flow meters (M, MS, MW, ...), pressure controllers and gauges (PC, PCD, P), liquid flow devices (L, LC): any Alicat with RS-232/RS-485 ASCII serial (not Modbus/Profibus/EtherNet/IP builds) |
| Interfaces | RS-232, RS-485 (up to 26 devices per port, unit IDs A-Z), USB (virtual COM port), Ethernet via a serial-to-Ethernet bridge |
| Protocol | Alicat ASCII serial (Serial Communications Primer, Rev. 2, Feb 2023; Operating Manual DOC-MANUAL-MPL, Rev. 2, "Digital Control") |
| Status | 🧪 simulated: tested against a wire-level Alicat simulator, not yet verified on hardware. Report a hardware test |
uvx labmcp-alicat --simulate --check
The simulator is an MC-500SCCM-D on firmware 10v20 flowing N2, with a first-order flow response, a small sensor zero offset (remove it with tare_flow) and realistic data frames.
@ streaming).get_device_info warns about this).uvx labmcp ports uvx labmcp-alicat --address /dev/ttyUSB0 --check # Linux
uvx labmcp-alicat --address /dev/tty.usbserial-XXXX --check # macOS uvx labmcp-alicat --address COM4 --check # Windows uvx labmcp-alicat --address COM4 --option unit_id=B --check # device B on a shared bus uvx labmcp-alicat --address tcp://192.168.1.60:4001 --check # serial-to-Ethernet bridge
Non-default baud rates go in the address: `serial://COM4?baudrate=115200`.
Claude Code
claude mcp add alicat -- uvx labmcp-alicat --address /dev/ttyUSB0
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "alicat": { "command": "uvx", "args": ["labmcp-alicat", "--address", "/dev/ttyUSB0", "--limit", "max_setpoint=200"] } } }
Add --read-only to allow reading flow but block setpoints, gas changes, tares and valve holds (close_valve stays available). For several devices on one bus, add one server entry per unit ID (--option unit_id=A, --option unit_id=B, ...). For other clients, generate the snippet with uvx labmcp config alicat --address /dev/ttyUSB0 --client vscode.
| Tool | Kind | Description |
|---|---|---|
close_valve | 🛑 safety | Stop the flow: set the flow setpoint to 0 and hold all valves closed (Alicat HC). Safe to call at any time. On pressure controllers the pressure setpoint is left unchanged and the valves are held closed, trapping the current pressure. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Report model, serial number, firmware, calibration date, whether the device is a controller, the units of every data-frame field, the setpoint full scale and setpoint source. |
hold_valve | 🎛 control | Freeze the controller's valve(s) at their current position (HLD): closed-loop control stops, so flow will drift if upstream pressure changes. Use resume_control to release, or close_valve to shut off completely. |
list_gases | 👁 read | List the gases installed on this mass flow device (number and short name), as used by set_gas. Liquid and pressure-only devices have no gas list. |
log_flow_series | 👁 read | Record a time series of data frames (e.g. to check flow stability, settling after a setpoint change, or pressure drift). Returns every point plus mean/stdev/min/max of the mass flow (or the main measured quantity for non-flow devices). |
read_flow | 👁 read | Read the live data frame: mass flow, volumetric flow, pressure, temperature, setpoint (controllers), active gas and any status codes, each with the device's engineering units. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
resume_control | ⚠️ hazard | Cancel any valve hold and resume closed-loop control to the current setpoint. Flow restarts immediately if the setpoint is not 0 (check it with read_flow first). |
set_flow_setpoint | ⚠️ hazard | Change the controller setpoint: starts, changes or stops gas flow (or sets the target pressure on a pressure controller). 0 stops flow and closes the valve on a flow controller. Negative values only work on bidirectional controllers. Refused on meters, above the max_setpoint limit, and above the device's full scale. |
set_gas | 🎛 control | Select the gas calibration the mass flow device uses (Gas Select). This changes how flow is computed, so do it with the setpoint at 0. Only gases installed on the device work (see list_gases); corrosive gases need anti-corrosive (S-series) hardware. |
tare_flow | 🎛 control | Tare (zero) the flow reading. ONLY run with no flow through the device: upstream shut off or controller setpoint 0, with the line at its normal operating pressure. Refused if the setpoint is not 0 or a significant flow is still being measured. |
tare_pressure | 🎛 control | Tare a pressure reading. Requires no flow and the device OPEN TO ATMOSPHERE (gauge), or no flow and an unpressurised process line (absolute, barometer-equipped devices only). |
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
| Limit | Default | Meaning |
|---|---|---|
max_setpoint | 100 (device units) | Largest setpoint magnitude an agent may send, in the controller's own setpoint units (SCCM, SLPM, PSIA, ... as shown by get_device_info). Setpoints above the device's full scale are refused as well. |
max_series_duration_s | 600 s | Longest logging series an agent may start (never more than 850 s, so a series always finishes within one tool call) |
Override at launch, e.g. --limit max_setpoint=500. The default of 100 is deliberately conservative: on a 500 SCCM controller it caps the agent at 100 SCCM until you raise it.
??D*) and parses every poll against it, so field names, order and engineering units come from the device itself (both the 6v+ column table and the older pre-6v table are understood). If a device does not answer ??D*, frames are parsed by position using the default layouts in the Serial Primer (p. 8) and the manual; layout_source in every reading says which method was used.LS on firmware 9v00+ and S on older firmware. After every change the reply is checked: if the controller reports a different requested setpoint (out of range, negative on a unidirectional device, or an analog setpoint source), the tool reports an error with what the device is now using.HC (hold valves closed, firmware 5v07+), and confirms HLD in the reply. On a pressure controller it only sends HC, because a 0 pressure setpoint can *open* valves depending on the zero-pressure-control setting (Serial Primer p. 17). resume_control (C) releases the hold; it is marked as a hazard because flow restarts at the current setpoint.tare_flow and tare_pressure refuse if a flow controller's setpoint is not 0, or if the device still reads more than 2% of full scale. They cannot detect every unsafe situation (e.g. a meter with a small real flow), so still shut the gas off first. Gauge-pressure tares need the port open to atmosphere; absolute tares need the barometer option and an unpressurised line..csv file: ~ is expanded, missing folders are created, and an existing file is never overwritten. The path is checked before logging starts.GS (10v05+, not saved as the power-up gas unless save_as_power_up) or the older G. Only gases installed on the device are accepted; list_gases shows them.A49408) is Alicat's legacy *integer setpoint* command. The driver refuses to send anything of that shape.$$ after the unit ID), streaming mode (@), Modbus/Profibus/EtherNet/IP variants, totalizer, batching, PID tuning and COMPOSER mix creation.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |