World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 97 tools.
MCP server for programmable DC bench power supplies from Rigol, Siglent and Aim-TTi.
Pick the AI app you use, then copy the settings.
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
One time only; it works for every server that needs Python (uv)
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-bench-psu": {
"command": "uvx",
"args": [
"labmcp-bench-psu"
]
}
}
}Use Bench DC Power Supply and tell me what you can do for me, then show me one thing✓ If Claude says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect Bench DC Power Supply yet
Bench DC Power Supply runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect Bench DC Power Supply
B · Others in Other that work with ChatGPT
Picked from the most used in the same category, only ones that connect by address with no key
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
One time only; it works for every server that needs Python (uv)
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-bench-psu -- uvx labmcp-bench-psuYou should see Bench DC Power Supply listed as connected
Use Bench DC Power Supply and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
One time only; it works for every server that needs Python (uv)
Use Bench DC Power Supply and tell me what you can do for me, then show me one thing✓ If Cursor says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
One time only; it works for every server that needs Python (uv)
Use Bench DC Power Supply and tell me what you can do for me, then show me one thing✓ If VS Code says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-bench-psu -- uvx labmcp-bench-psuClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-bench-psu": {
"command": "uvx",
"args": [
"labmcp-bench-psu"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-bench-psu": {
"command": "uvx",
"args": [
"labmcp-bench-psu"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-bench-psu": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-bench-psu"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-bench-psuBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 14, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.3) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: World Monitor, Claude Flow, Windmill
Servers in the same category from other makers, sorted by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 97 tools.
AI orchestration with hive-mind swarms, neural networks, and 87 MCP tools for enterprise dev.
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent set voltages and current limits, switch outputs on and off, watch constant-voltage / constant-current behaviour and configure over-voltage / over-current protection on programmable DC bench power supplies from Rigol, Siglent and Aim-TTi, using each vendor's documented remote command set. The dialect is detected from *IDN?.
| Package | labmcp-bench-psu |
| Instruments | Rigol DP832/DP832A, DP831, DP822, DP821, DP811, DP813, DP711, DP712, DP932A/U/E; Siglent SPD3303X/X-E, SPD1168X, SPD1305X; Aim-TTi CPX400D/DP, MX100T/TP, MX180T/TP, QL355/QL564 (P, T/TP), PL-P (PL068/155/303/601, PL303QMD/QMT) |
| Interfaces | USB (USB-TMC via VISA, or virtual COM on Aim-TTi), LAN (VISA/VXI-11 or raw socket), RS-232, GPIB via VISA |
| Protocol | SCPI (Rigol DP800 Programming Guide, DP700, DP900; Siglent SPD3303X Quick Start, SPD1000X User Manual) and Aim-TTi remote commands (CPX400D/DP manual, MX100T/TP manual, manuals index) |
| Status | 🧪 simulated: tested against wire-level simulators of each dialect driving a resistive load, not yet verified on hardware. Report a hardware test |
Keysight / Agilent and Rohde & Schwarz supplies are intentionally not covered: both vendors publish official MCP servers. Use the Keysight MCP Server for Instrument Control or the MCP server included in Rohde & Schwarz RsInstrument. This server refuses to connect to them.
uvx labmcp-bench-psu --simulate --check # Rigol DP832
uvx labmcp-bench-psu --simulate --option dialect=siglent --check # Siglent SPD3303X uvx labmcp-bench-psu --simulate --option dialect=tti --option sim_model=MX100TP --check
The simulated outputs drive resistive loads (CH1 10 Ω, CH2 100 Ω, CH3 open), so you can watch the CV → CC crossover and trip OVP/OCP.
uvx labmcp ports (serial) or python -m pyvisa info / your VISA vendor's tool (USB/LAN). uvx labmcp-bench-psu --address "USB0::0x1AB1::0x0E11::DP8C123456789::INSTR" --check # Rigol over USB-TMC
uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --check # any LXI/VXI-11 supply uvx labmcp-bench-psu --address tcp://192.168.1.51:5025 --check # Siglent raw socket uvx labmcp-bench-psu --address tcp://192.168.1.52:9221 --check # Aim-TTi raw socket uvx labmcp-bench-psu --address /dev/ttyACM0 --check # Aim-TTi USB virtual COM uvx labmcp-bench-psu --address "serial://COM3?write_termination=CRLF" --check # Rigol DP800 RS-232
USB-TMC and VXI-11 addresses use PyVISA (installed with this package; add `?backend=@ivi` to use NI-VISA / Keysight IO Libraries instead of pyvisa-py).
Claude Code
claude mcp add psu -- uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --limit max_voltage_v=12 --limit max_current_a=1
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "psu": { "command": "uvx", "args": ["labmcp-bench-psu", "--address", "TCPIP0::192.168.1.50::INSTR", "--limit", "max_voltage_v=12", "--limit", "max_current_a=1"] } } }
Add --read-only to allow monitoring only: setpoint changes and output_on are hidden, while output_off and all_outputs_off stay available. For other clients, generate the snippet with uvx labmcp config bench-psu --address TCPIP0::192.168.1.50::INSTR --client vscode.
| Tool | Kind | Description |
|---|---|---|
all_outputs_off | 🛑 safety | Switch every output OFF (emergency stop for the whole supply). Each channel is switched individually and read back where the instrument supports it. |
clear_protection_trip | 🎛 control | Clear an OVP/OCP trip after fixing its cause. The output stays OFF; use output_on to re-energise. On Aim-TTi supplies this clears trips on all outputs. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_errors | 👁 read | Read (and clear) the instrument's error queue / error registers. Empty list = no errors. |
get_outputs | 👁 read | Report each channel: voltage and current-limit setpoints, measured voltage/current/power, output on/off, CV/CC mode, and OVP/OCP levels and trip state where the model supports them. |
output_off | 🛑 safety | Switch a channel's output OFF. Safe to call at any time. |
output_on | ⚠️ hazard | Switch a channel's output ON, energising the connected load at the present setpoints. The setpoints are read back first and the output is refused if they exceed the safety limits (e.g. after someone changed them on the front panel). |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_current_limit | 🎛 control | Set a channel's current limit (the constant-current setpoint). Refused above max_current_a (checked even with the output off) or above the channel's range. |
set_protection | 🎛 control | Set over-voltage (OVP) and/or over-current (OCP) protection for a channel. When exceeded, the supply switches the output off. Rigol: levels + on/off; Aim-TTi CPX/QL/PL-P: levels (always armed), MX: levels + on/off; Siglent SPD1000X: levels only; SPD3303X: not available. |
set_voltage | 🎛 control | Set a channel's voltage setpoint. Refused above max_voltage_v (checked even with the output off) or above the channel's range. If the output is on, the load sees the new voltage at once. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
| Limit | Default | Meaning |
|---|---|---|
max_voltage_v | 30 V | Largest voltage setpoint (magnitude) on any channel. Checked when setting the voltage, even with the output off, and again before output_on |
max_current_a | 3 A | Largest current-limit setpoint on any channel, checked the same way |
Override at launch, e.g. --limit max_voltage_v=12 --limit max_current_a=0.5. Setpoints are also checked against each model's settable range. output_on reads the setpoints back from the instrument first, so a value changed on the front panel cannot slip past the limits.
*IDN? manufacturer "RIGOL" → Rigol, "Siglent" → Siglent, "THURLBY THANDAR"/"TTi"/"Aim" → Aim-TTi. Force one with --option dialect=rigol|siglent|tti for rebadged units. Models not in the built-in table are treated as --option channels=N channels with no model maxima (the safety limits still apply).:SOUR :VOLT/CURR, readback via :APPL? CHn and :MEAS:ALL? CHn, mode via :OUTP:MODE? CHn (CV/CC/UR), OVP/OCP via :OUTP:OVP|OCP[:STAT|:VAL|:QUES?]. Trips are cleared with :OUTP:OVP|OCP:CLEAR, which only clears the flag. [:SOUR]:VOLT:PROT:CLE is never sent because the programming guide says it also turns the output on. DP831 CH3 is a negative output: give negative voltages (not yet verified on hardware). Over RS-232 the DP800 needs CR LF line endings (?write_termination=CRLF).SYST:STAT? status word (CH1/CH2). CH3 is fixed (2.5/3.3/5 V by front-panel switch) and can only be switched on/off; its state is not readable. SPD1000X has OVP/OCP levels only (always armed, trip state not readable). The error reply format (0 No Error) is not SCPI-standard, so settings are verified by reading them back. The server pauses 0.1 s after each command to Siglent supplies (--option write_delay_s= to change); Siglent's own examples wait between commands, but the required delay is not documented.mode is inferred from readback vs setpoints (mode_source: "inferred"). Trip flags come from the LSR ? limit event register, which latches events and is cleared by reading it. CPX/QL/PL-P protection is always armed (levels only); MX models can also switch OVP/OCP on/off. TRIPRST clears trips on all outputs (not documented for MX100T/TP). Original QL P/T models have no output-state query, so their output_on is reported as unknown. OPALL 0 is sent first in all_outputs_off, then every output individually.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |