Prototype · Preview: every server in the official registry, synced every 30 minutes. Sign in with Google to write reviews.Prototype · updated every 30 min
PopNx MCPMCP servers for people who use AI · explained in plain words

Bench DC Power Supply

by K-Dense-AIversion 0.1.3i★ 30 (Stars for the whole repo)iRuns on your computer
Registry nameio.github.K-Dense-AI/labmcp-bench-psu

How to install

What it does

MCP server for programmable DC bench power supplies from Rigol, Siglent and Aim-TTi.

  • Connects Runs on your computer
  • Account or key No key needed
  • Category Other

Install

Pick the AI app you use, then copy the settings.

Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026

First: which AI do you use?

Pick your app and the steps appear below.

Works with Claude, with some setup first

Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone

  1. Install Python (uv)

    One time only; it works for every server that needs Python (uv)

    Open the Python (uv) download page ↗

  2. Open the Claude desktop app’s settings file

    SettingsDeveloperEdit Config

  3. Paste these settings and save the file

    {
      "mcpServers": {
        "labmcp-bench-psu": {
          "command": "uvx",
          "args": [
            "labmcp-bench-psu"
          ]
        }
      }
    }
  4. Quit Claude and open it again

  5. Try it

    Use Bench DC Power Supply and tell me what you can do for me, then show me one thing

    ✓ If Claude says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version

ChatGPT cannot connect Bench DC Power Supply yet

Bench DC Power Supply runs on your computer, but ChatGPT can only connect servers that run on the web

What you can do instead

A · Use an app that can connect Bench DC Power Supply

  • Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
  • Install Python (uv) on your computer first (one time)
  • Install Python (uv) on your computer first (one time)
  • Install Python (uv) on your computer first (one time)

B · Others in Other that work with ChatGPT

Picked from the most used in the same category, only ones that connect by address with no key

Works with Claude Code, with some setup first

Install Python (uv) on your computer first (one time)

  1. Install Python (uv)

    One time only; it works for every server that needs Python (uv)

    Open the Python (uv) download page ↗

  2. Open Terminal

    Mac: press Command+Space and type Terminal · Windows: open PowerShell

  3. Paste this command and press Enter

    claude mcp add --scope user labmcp-bench-psu -- uvx labmcp-bench-psu
  4. Type /mcp in Claude Code

    You should see Bench DC Power Supply listed as connected

  5. Try it

    Use Bench DC Power Supply and tell me what you can do for me, then show me one thing

    ✓ If Claude Code says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Works with Cursor, with some setup first

Install Python (uv) on your computer first (one time)

  1. Install Python (uv)

    One time only; it works for every server that needs Python (uv)

    Open the Python (uv) download page ↗

  2. Click this button to open Cursor

    Open in Cursor

    Cursor asks you to confirm; click Install

  3. Open the AI chat in Cursor in Agent mode

  4. Try it

    Use Bench DC Power Supply and tell me what you can do for me, then show me one thing

    ✓ If Cursor says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Works with VS Code, with some setup first

Install Python (uv) on your computer first (one time)

  1. Install Python (uv)

    One time only; it works for every server that needs Python (uv)

    Open the Python (uv) download page ↗

  2. Click this button to open VS Code

    Open in VS Code

    VS Code asks you to confirm; click Install

  3. Open the AI chat in VS Code in Agent mode

  4. Try it

    Use Bench DC Power Supply and tell me what you can do for me, then show me one thing

    ✓ If VS Code says it is using Bench DC Power Supply or shows a Bench DC Power Supply tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.

See every app that uses MCP →

JSON settings are under “For developers” below

Stuck? Ask people who use Bench DC Power Supply💬 Discussion →
For developers: Terminal commands and JSON settings

Installed on your computer

Claude Code

claude mcp add --scope user labmcp-bench-psu -- uvx labmcp-bench-psu

Claude Desktop (claude_desktop_config.json)

{
  "mcpServers": {
    "labmcp-bench-psu": {
      "command": "uvx",
      "args": [
        "labmcp-bench-psu"
      ]
    }
  }
}

Cursor (~/.cursor/mcp.json)

{
  "mcpServers": {
    "labmcp-bench-psu": {
      "command": "uvx",
      "args": [
        "labmcp-bench-psu"
      ]
    }
  }
}

VS Code (mcp.json)

{
  "servers": {
    "labmcp-bench-psu": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-bench-psu"
      ]
    }
  }
}

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

At a glance

GitHub starsi
30 (Stars for the whole repo)
This repo holds several MCP listings; its stars count once in rankings
Downloads per weeki
46/wk
Licencei
Apache-2.0
Connection
Runs on your computer
Latest versioni
0.1.3
Categoryi
Other
Published to registryi
Sep 27, 2026
Code last changedi
Sep 27, 2026
Maker
K-Dense-AI
Packages
pypi: labmcp-bench-psu
Website
github.com
Registry status
Active

Which apps can use it

Based on how this server connects and on each app’s own docs, checked Nov 10, 2026.

Run on your computer in

ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast

All apps, with pros and cons →

Related guides

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 14, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • ✓ Pass

    Still maintained

    Code last changed 2 months ago

  • ✓ Pass

    Has a licence

    Uses Apache-2.0

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Discussion

Ask, share a tip or report that it does not work. Sorted by what people marked helpful.

No posts yet. Be the first to ask or share.

Posts here are written by users, not the PopNx team.

Sign in with Google to post

User reviews

No reviews yet

Sign in with Google to write a review

Compared with others in Otheri

  • More stars than 95% of the other 19732 servers in this category
  • Published to the registry more recently than 48% of the other 19732 servers in this category
  • Basic checks equal to or better than 100% of the other 19732 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Bench DC Power Supply safe?

It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed 2 months ago, and the latest version (0.1.3) reached the registry 2 months ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: World Monitor, Claude Flow, Windmill

Others in the same category

Servers in the same category from other makers, sorted by stars.

Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

World Monitor

Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 97 tools.

by koala73Widely used★ 90.6KUpdated yesterday

Runs in the cloud✓ service owner · worldmonitor.app

Claude Flow

AI orchestration with hive-mind swarms, neural networks, and 87 MCP tools for enterprise dev.

by ruvnetWidely used↓ 13.5K/wk★ 81.6KUpdated 14 months ago

Runs on your computer

Windmill

Run Windmill scripts and flows and manage jobs, schedules, resources and variables.

by windmill-labsWidely used★ 18.6KUpdated 2 days ago

Runs in the cloud

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Bench DC Power Supply — MCP Server

Let an AI agent set voltages and current limits, switch outputs on and off, watch constant-voltage / constant-current behaviour and configure over-voltage / over-current protection on programmable DC bench power supplies from Rigol, Siglent and Aim-TTi, using each vendor's documented remote command set. The dialect is detected from *IDN?.

Packagelabmcp-bench-psu
InstrumentsRigol DP832/DP832A, DP831, DP822, DP821, DP811, DP813, DP711, DP712, DP932A/U/E; Siglent SPD3303X/X-E, SPD1168X, SPD1305X; Aim-TTi CPX400D/DP, MX100T/TP, MX180T/TP, QL355/QL564 (P, T/TP), PL-P (PL068/155/303/601, PL303QMD/QMT)
InterfacesUSB (USB-TMC via VISA, or virtual COM on Aim-TTi), LAN (VISA/VXI-11 or raw socket), RS-232, GPIB via VISA
ProtocolSCPI (Rigol DP800 Programming Guide, DP700, DP900; Siglent SPD3303X Quick Start, SPD1000X User Manual) and Aim-TTi remote commands (CPX400D/DP manual, MX100T/TP manual, manuals index)
Status🧪 simulated: tested against wire-level simulators of each dialect driving a resistive load, not yet verified on hardware. Report a hardware test

Keysight / Agilent and Rohde & Schwarz supplies are intentionally not covered: both vendors publish official MCP servers. Use the Keysight MCP Server for Instrument Control or the MCP server included in Rohde & Schwarz RsInstrument. This server refuses to connect to them.

Try it without hardware

uvx labmcp-bench-psu --simulate --check                                        # Rigol DP832

uvx labmcp-bench-psu --simulate --option dialect=siglent --check # Siglent SPD3303X uvx labmcp-bench-psu --simulate --option dialect=tti --option sim_model=MX100TP --check

The simulated outputs drive resistive loads (CH1 10 Ω, CH2 100 Ω, CH3 open), so you can watch the CV → CC crossover and trip OVP/OCP.

Connect your instrument

  1. Instrument setup: enable the interface you use (Rigol: Utility → I/O Config; Siglent: System → Interface; Aim-TTi: LAN works out of the box, USB appears as a virtual COM port). Note the IP address or VISA resource string.
  2. Find the address: uvx labmcp ports (serial) or python -m pyvisa info / your VISA vendor's tool (USB/LAN).
  3. Test the connection:
   uvx labmcp-bench-psu --address "USB0::0x1AB1::0x0E11::DP8C123456789::INSTR" --check   # Rigol over USB-TMC

uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --check # any LXI/VXI-11 supply uvx labmcp-bench-psu --address tcp://192.168.1.51:5025 --check # Siglent raw socket uvx labmcp-bench-psu --address tcp://192.168.1.52:9221 --check # Aim-TTi raw socket uvx labmcp-bench-psu --address /dev/ttyACM0 --check # Aim-TTi USB virtual COM uvx labmcp-bench-psu --address "serial://COM3?write_termination=CRLF" --check # Rigol DP800 RS-232

   USB-TMC and VXI-11 addresses use PyVISA (installed with this package; add `?backend=@ivi` to use NI-VISA / Keysight IO Libraries instead of pyvisa-py).

Add to your MCP client

Claude Code

claude mcp add psu -- uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --limit max_voltage_v=12 --limit max_current_a=1

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "psu": { "command": "uvx", "args": ["labmcp-bench-psu", "--address", "TCPIP0::192.168.1.50::INSTR", "--limit", "max_voltage_v=12", "--limit", "max_current_a=1"] } } }

Add --read-only to allow monitoring only: setpoint changes and output_on are hidden, while output_off and all_outputs_off stay available. For other clients, generate the snippet with uvx labmcp config bench-psu --address TCPIP0::192.168.1.50::INSTR --client vscode.

Tools

ToolKindDescription
all_outputs_off🛑 safetySwitch every output OFF (emergency stop for the whole supply). Each channel is switched individually and read back where the instrument supports it.
clear_protection_trip🎛 controlClear an OVP/OCP trip after fixing its cause. The output stays OFF; use output_on to re-energise. On Aim-TTi supplies this clears trips on all outputs.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_errors👁 readRead (and clear) the instrument's error queue / error registers. Empty list = no errors.
get_outputs👁 readReport each channel: voltage and current-limit setpoints, measured voltage/current/power, output on/off, CV/CC mode, and OVP/OCP levels and trip state where the model supports them.
output_off🛑 safetySwitch a channel's output OFF. Safe to call at any time.
output_on⚠️ hazardSwitch a channel's output ON, energising the connected load at the present setpoints. The setpoints are read back first and the output is refused if they exceed the safety limits (e.g. after someone changed them on the front panel).
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_current_limit🎛 controlSet a channel's current limit (the constant-current setpoint). Refused above max_current_a (checked even with the output off) or above the channel's range.
set_protection🎛 controlSet over-voltage (OVP) and/or over-current (OCP) protection for a channel. When exceeded, the supply switches the output off. Rigol: levels + on/off; Aim-TTi CPX/QL/PL-P: levels (always armed), MX: levels + on/off; Siglent SPD1000X: levels only; SPD3303X: not available.
set_voltage🎛 controlSet a channel's voltage setpoint. Refused above max_voltage_v (checked even with the output off) or above the channel's range. If the output is on, the load sees the new voltage at once.

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

LimitDefaultMeaning
max_voltage_v30 VLargest voltage setpoint (magnitude) on any channel. Checked when setting the voltage, even with the output off, and again before output_on
max_current_a3 ALargest current-limit setpoint on any channel, checked the same way

Override at launch, e.g. --limit max_voltage_v=12 --limit max_current_a=0.5. Setpoints are also checked against each model's settable range. output_on reads the setpoints back from the instrument first, so a value changed on the front panel cannot slip past the limits.

Example prompts

  • "Show me all channels of the power supply: setpoints, measured current and whether they're in CV or CC."
  • "Set CH1 to 12 V with a 200 mA current limit, set OVP at 13 V, then turn it on and tell me how much current the LED array draws."
  • "Ramp CH2 from 0 to 5 V in 0.5 V steps, reading the current at each step, and plot the I-V curve of the load."
  • "The heater is drawing more than expected: turn every output off now."
  • "Channel 1 tripped. What happened, and is it safe to clear the trip?"

Notes

  • Dialect detection: *IDN? manufacturer "RIGOL" → Rigol, "Siglent" → Siglent, "THURLBY THANDAR"/"TTi"/"Aim" → Aim-TTi. Force one with --option dialect=rigol|siglent|tti for rebadged units. Models not in the built-in table are treated as --option channels=N channels with no model maxima (the safety limits still apply).
  • Rigol: setpoints via :SOUR :VOLT/CURR, readback via :APPL? CHn and :MEAS:ALL? CHn, mode via :OUTP:MODE? CHn (CV/CC/UR), OVP/OCP via :OUTP:OVP|OCP[:STAT|:VAL|:QUES?]. Trips are cleared with :OUTP:OVP|OCP:CLEAR, which only clears the flag. [:SOUR]:VOLT:PROT:CLE is never sent because the programming guide says it also turns the output on. DP831 CH3 is a negative output: give negative voltages (not yet verified on hardware). Over RS-232 the DP800 needs CR LF line endings (?write_termination=CRLF).
  • Siglent: SPD3303X/X-E have no programmable OVP/OCP and report output state and CV/CC only through the SYST:STAT? status word (CH1/CH2). CH3 is fixed (2.5/3.3/5 V by front-panel switch) and can only be switched on/off; its state is not readable. SPD1000X has OVP/OCP levels only (always armed, trip state not readable). The error reply format (0 No Error) is not SCPI-standard, so settings are verified by reading them back. The server pauses 0.1 s after each command to Siglent supplies (--option write_delay_s= to change); Siglent's own examples wait between commands, but the required delay is not documented.
  • Aim-TTi: there is no live CV/CC query, so mode is inferred from readback vs setpoints (mode_source: "inferred"). Trip flags come from the LSR ? limit event register, which latches events and is cleared by reading it. CPX/QL/PL-P protection is always armed (levels only); MX models can also switch OVP/OCP on/off. TRIPRST clears trips on all outputs (not documented for MX100T/TP). Original QL P/T models have no output-state query, so their output_on is reported as unknown. OPALL 0 is sent first in all_outputs_off, then every output individually.
  • Tracking / series / parallel modes, timers, sequences, remote sense and saved set-ups are not exposed. Put the supply in independent mode before handing it to an agent.
  • GW Instek GPP and B&K Precision 9130/9140 supplies are not supported yet: too many reply formats are undocumented in their manuals to implement them safely.

Hardware verification

ModelFirmwareInterfaceVerified byDate
*none yet: be the first*