World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
MCP server for JULABO heating and refrigerated circulators (CORIO, MAGIO, DYNEO).
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 0/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 7/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 7/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install JULABO Circulator. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-julabo.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server JULABO Circulator for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-julabo": { "command": "uvx", "args": [ "labmcp-julabo" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the JULABO Circulator tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-julabo": {
"command": "uvx",
"args": [
"labmcp-julabo"
]
}
}
}Use JULABO Circulator and tell me what you can do for me, then show me one thing✓ If Claude says it is using JULABO Circulator or shows a JULABO Circulator tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect JULABO Circulator yet
JULABO Circulator runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect JULABO Circulator
B · Others in Other that work with ChatGPT
Picked from the most used in the same category, only ones that connect by address with no key
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server JULABO Circulator for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-julabo -- uvx labmcp-julabo 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the JULABO Circulator tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-julabo -- uvx labmcp-julaboYou should see JULABO Circulator listed as connected
Use JULABO Circulator and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using JULABO Circulator or shows a JULABO Circulator tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server JULABO Circulator for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-julabo": { "command": "uvx", "args": [ "labmcp-julabo" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the JULABO Circulator tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use JULABO Circulator and tell me what you can do for me, then show me one thing✓ If Cursor says it is using JULABO Circulator or shows a JULABO Circulator tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server JULABO Circulator for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-julabo": { "type": "stdio", "command": "uvx", "args": [ "labmcp-julabo" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the JULABO Circulator tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use JULABO Circulator and tell me what you can do for me, then show me one thing✓ If VS Code says it is using JULABO Circulator or shows a JULABO Circulator tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-julabo -- uvx labmcp-julaboClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-julabo": {
"command": "uvx",
"args": [
"labmcp-julabo"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-julabo": {
"command": "uvx",
"args": [
"labmcp-julabo"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-julabo": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-julabo"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-julaboBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
No entries on OSV.dev for labmcp-julabo@0.1.2
Checks only this package version, not every dependency · checked Nov 16, 2026
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-julabo)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.2) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
Manage monitors, status pages, incidents and maintenances in your openstatus workspace.
Validate oh-my-posh configurations and segment snippets against the official schema.
MCP server for progressive tool usage at any scale (see https://klavis.ai)
Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.
| This one JULABO Circulator | World Monitor | openstatus | Oh My Posh Validator | Strata | Jitsu | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install |
| Needs a key | No | No | No | No | No | No |
| Add with + in Claude | No | No | No | No | No | No |
| Basic checks | 3/3 | 4/4 | 4/4 | 4/4 | 1/4 | 4/4 |
| License | Apache-2.0 | AGPL-3.0 | AGPL-3.0 | MIT | Apache-2.0 | MIT |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent run JULABO heating and refrigerated circulators through JULABO's documented interface commands: read the bath and external temperatures and the heating/cooling power, set the setpoint, start and stop temperature control, decode status and alarm messages, and wait until the bath is stable at temperature.
| Package | labmcp-julabo |
| Instruments | CORIO CD, CORIO CP, MAGIO MS (and MX), DYNEO DD circulators. PRESTO and older JULABO models use a similar command set but are unverified |
| Interfaces | USB (virtual COM port), RS-232 (CORIO CP, MAGIO, DYNEO) |
| Protocol | JULABO interface commands, appendix "Interface commands" of the original operating manuals: CORIO CD (1.950.0800.us.V10), CORIO CP (1.950.0900.us.V04), MAGIO MS (1.950.1700.us.V05), DYNEO DD (1.950.1300.us.V03). Official downloads: julabo.com |
| Status | 🧪 simulated: tested against a wire-level simulator, not yet verified on hardware. Report a hardware test |
uvx labmcp-julabo --simulate --check
MENU → IntE → rEM → USb (or 232 for RS-232). rOFF appears in standby.?rtscts=true to the address to enforce it.uvx labmcp ports uvx labmcp-julabo --address /dev/ttyACM0 --check # Linux (USB)
uvx labmcp-julabo --address /dev/tty.usbmodem1101 --check # macOS uvx labmcp-julabo --address COM3 --check # Windows uvx labmcp-julabo --address "serial://COM3?baudrate=9600" --check # RS-232, non-default baud rate
`--check` prints the firmware string (`version`) and the current status, e.g. `02 REMOTE STOP`.
Claude Code
claude mcp add julabo -- uvx labmcp-julabo --address /dev/ttyACM0
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "julabo": { "command": "uvx", "args": ["labmcp-julabo", "--address", "/dev/ttyACM0", "--limit", "max_temperature_c=120"] } } }
Add --read-only to allow monitoring only (stop_circulation stays available). For other clients: uvx labmcp config julabo-circulator --address /dev/ttyACM0 --client vscode.
| Tool | Kind | Description |
|---|---|---|
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_setpoint | 👁 read | Read the current temperature setpoint and whether temperature control is running. |
get_status | 👁 read | Report the circulator's status message (decoded: operating state, rejected command or alarm), whether temperature control is running, the setpoint, the device's own excess-temperature protection setting and warning limits, and the firmware version. |
read_temperatures | 👁 read | Read the bath temperature, the heating/cooling power in % and the safety-sensor temperature, and optionally the external Pt100 sensor. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
set_setpoint | ⚠️ hazard | Set the circulator's temperature setpoint (out_sp_00). If temperature control is running, the circulator starts heating or cooling to it immediately. Refused outside min_temperature_c..max_temperature_c; the circulator itself also rejects values outside its range or warning limits (reported as an error). Needs remote control enabled. |
start_circulation | ⚠️ hazard | Start temperature control (out_mode_05 1): the pump runs and the bath heats or cools to the setpoint, which is checked against the safety limits first (it may have been changed on the front panel). Make sure the bath is filled and any external hoses are connected and secured. Needs remote control enabled. |
stop_circulation | 🛑 safety | Stop temperature control and the pump (out_mode_05 0), then confirm with in_mode_05. Also ends a running wait_for_temperature. The bath stays hot/cold after stopping. |
wait_for_temperature | 👁 read | Poll the bath (or external) temperature until it has been within tolerance_c of the target for stable_for_s seconds, or timeout_s passes. Does not change anything; start circulation first. Stops early (reached = false) if the circulator raises an alarm or a stop command is sent. Returns a short temperature trace. |
| Limit | Default | Meaning |
|---|---|---|
max_temperature_c | 90 °C | Highest setpoint an agent may set (also checked before start_circulation) |
min_temperature_c | 5 °C | Lowest setpoint an agent may set (also checked before start_circulation) |
max_wait_s | 7200 s | Longest wait_for_temperature |
The defaults suit a water bath. Set them to your bath fluid's working range, e.g. --limit min_temperature_c=-30 --limit max_temperature_c=150 for a silicone oil / glycol-rated setup. The circulator additionally enforces its own working range, warning limits and excess-temperature protection; rejections come back as errors such as -11 VALUE TOO LARGE.
00 MANUAL STOP / 01 MANUAL START) the server refuses to send settings and tells you how to enable remote control.status (to catch -08 INVALID COMMAND, -09 COMMAND NOT ALLOWED IN CURRENT OPERATING MODE, -10 VALUE TOO SMALL, -11 VALUE TOO LARGE, -13 VALUE EXCEEDS TEMPERATURE LIMITS) and reads the setpoint or in_mode_05 back. stop_circulation retries once and reports an error if the circulator still says it is running.in_sp_03/04) need CORIO CP, MAGIO or DYNEO; the external Pt100 (in_pv_02) needs MAGIO or DYNEO. The server detects missing commands (no reply) and reports those values as null.command_delay_s (default 0.25 s) after each setting command before checking status; change it with --option command_delay_s=0.5 if your circulator misses commands.--option keepalive_s=10 (queries status every 10 s). JULABO's alarm list notes that it expects the setpoint at least every 30 s in "setpoint" restart mode, which this keep-alive does not do.-01, -14, -63, ...) using the alarm tables in the manuals; the exact wording the circulator sends is passed through unchanged.out_sp_07/27), warning-limit writes (out_sp_03/04), controller parameters (out_par_*), external/internal control switch (out_mode_04), EPROG and ATC calibration commands.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |