World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
MCP server for Keithley SourceMeter SMUs (2400 series SCPI, 2450 family SCPI, 2600B TSP).
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 0/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 7/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 7/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install Keithley SourceMeter SMU. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-keithley-smu.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Keithley SourceMeter SMU for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-keithley-smu": { "command": "uvx", "args": [ "labmcp-keithley-smu" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Keithley SourceMeter SMU tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-keithley-smu": {
"command": "uvx",
"args": [
"labmcp-keithley-smu"
]
}
}
}Use Keithley SourceMeter SMU and tell me what you can do for me, then show me one thing✓ If Claude says it is using Keithley SourceMeter SMU or shows a Keithley SourceMeter SMU tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect Keithley SourceMeter SMU yet
Keithley SourceMeter SMU runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect Keithley SourceMeter SMU
B · Others in Other that work with ChatGPT
Picked from the most used in the same category, only ones that connect by address with no key
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Keithley SourceMeter SMU for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-keithley-smu -- uvx labmcp-keithley-smu 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Keithley SourceMeter SMU tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-keithley-smu -- uvx labmcp-keithley-smuYou should see Keithley SourceMeter SMU listed as connected
Use Keithley SourceMeter SMU and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using Keithley SourceMeter SMU or shows a Keithley SourceMeter SMU tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Keithley SourceMeter SMU for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-keithley-smu": { "command": "uvx", "args": [ "labmcp-keithley-smu" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Keithley SourceMeter SMU tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Keithley SourceMeter SMU and tell me what you can do for me, then show me one thing✓ If Cursor says it is using Keithley SourceMeter SMU or shows a Keithley SourceMeter SMU tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Keithley SourceMeter SMU for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-keithley-smu": { "type": "stdio", "command": "uvx", "args": [ "labmcp-keithley-smu" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Keithley SourceMeter SMU tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Keithley SourceMeter SMU and tell me what you can do for me, then show me one thing✓ If VS Code says it is using Keithley SourceMeter SMU or shows a Keithley SourceMeter SMU tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-keithley-smu -- uvx labmcp-keithley-smuClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-keithley-smu": {
"command": "uvx",
"args": [
"labmcp-keithley-smu"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-keithley-smu": {
"command": "uvx",
"args": [
"labmcp-keithley-smu"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-keithley-smu": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-keithley-smu"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-keithley-smuBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
No entries on OSV.dev for labmcp-keithley-smu@0.1.2
Checks only this package version, not every dependency · checked Nov 16, 2026
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-keithley-smu)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.2) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
Manage monitors, status pages, incidents and maintenances in your openstatus workspace.
Validate oh-my-posh configurations and segment snippets against the official schema.
MCP server for progressive tool usage at any scale (see https://klavis.ai)
Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.
| This one Keithley SourceMeter SMU | World Monitor | openstatus | Oh My Posh Validator | Strata | Jitsu | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install |
| Needs a key | No | No | No | No | No | No |
| Add with + in Claude | No | No | No | No | No | No |
| Basic checks | 3/3 | 4/4 | 4/4 | 4/4 | 1/4 | 4/4 |
| License | Apache-2.0 | AGPL-3.0 | AGPL-3.0 | MIT | Apache-2.0 | MIT |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent source voltage or current with a compliance limit, measure V and I, and run bounded IV sweeps (linear, log, dual) on Keithley (Tektronix) SourceMeter SMUs. Every sweep ends with the output switched off, even when something goes wrong. The server speaks all three Keithley remote dialects: 2400-series SCPI, 2450-family SCPI, and 2600B TSP.
| Package | labmcp-keithley-smu |
| Instruments | 2400, 2400-LV, 2401, 2410, 2420, 2425, 2430 (DC mode), 2440 · 2450, 2460, 2461, 2470 (SCPI command set) · 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, 2634B, 2635B, 2636B |
| Interfaces | GPIB, USB (USBTMC), Ethernet (VXI-11 / raw socket 5025), RS-232 (2400 series), via VISA or tcp:// |
| Protocol | SCPI: 2400 Series User's Manual 2400S-900-01 Rev. K §18, 2450 Reference Manual 2450-901-01 Rev. D §6. TSP: 2600B Reference Manual 2600BS-901-01 Rev. F §9 |
| Status | 🧪 simulated: tested against wire-level simulators of all three dialects, not yet verified on hardware. Report a hardware test |
uvx labmcp-keithley-smu --simulate --check # 2450 + 1 kΩ resistor
uvx labmcp-keithley-smu --simulate --option dialect=2600 --option sim_dut=diode --check uvx labmcp-keithley-smu --simulate --option dialect=2400 --option sim_resistance_ohm=47 --check
The simulated DUT is a resistor (1 kΩ by default) or a 1N4148-like diode (Shockley equation, I_s = 2.52 nA, n = 1.752, R_s = 0.568 Ω). Compliance clamping behaves as on a real SMU.
SCPI2400 emulation mode it is driven with the 2400 dialect. Above ±21 V the 2450 needs its safety interlock closed.localnode.prompts disabled (the default); prompts would be mixed into replies.uvx labmcp ports (or python -m pyvisa info). GPIB and USBTMC need a VISA library with GPIB support. NI-VISA works everywhere; pyvisa-py covers USBTMC/LAN (and GPIB with gpib-ctypes/linux-gpib). uvx labmcp-keithley-smu --address GPIB0::24::INSTR --check
uvx labmcp-keithley-smu --address USB0::0x05E6::0x2450::04096331::INSTR --check uvx labmcp-keithley-smu --address tcp://192.168.1.50:5025 --check # 2450 / 2600B LAN uvx labmcp-keithley-smu --address TCPIP0::192.168.1.51::inst0::INSTR --option channel=b --check # 2602B, SMU B
The dialect is detected from `*IDN?` (and `*LANG?` on the 2450 family). Force it with `--option dialect=2400|2450|2600`.
Claude Code
claude mcp add smu -- uvx labmcp-keithley-smu --address GPIB0::24::INSTR --limit max_voltage_v=5 --limit max_current_a=0.02
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "smu": { "command": "uvx", "args": ["labmcp-keithley-smu", "--address", "USB0::0x05E6::0x2450::04096331::INSTR", "--limit", "max_voltage_v=5", "--limit", "max_current_a=0.02"] } } }
Add --read-only to allow status and measurements but block configuration, output-on and sweeps (output_off stays available). For other clients, generate the snippet with uvx labmcp config keithley-smu --address --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
configure_source | 🎛 control | Set up the source (function, level, compliance, range, measurement speed) while the output is OFF. Measures V and I with auto-ranging. Refused if the output is on; turn it off first or use set_source_level. Limits are checked before anything is sent. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Identify the SMU: manufacturer, model, serial, firmware, command dialect (2400 / 2450 / 2600), channel (2600B) and the model's maximum source voltage and current. |
get_status | 👁 read | Report whether the output is on, the source function (voltage/current), programmed level, compliance limit, whether the source is in compliance, terminals and 2/4-wire sense. |
measure | 👁 read | Take one source-measure reading (voltage, current, V/I, power, compliance flag) of the energised DUT. Does not change any setting; refused if the output is off. |
output_off | 🛑 safety | Switch the SMU output OFF immediately (and abort any IV sweep in progress). Always available, including in read-only mode. |
output_on | ⚠️ hazard | Switch the SMU output ON: the configured voltage or current is applied to the DUT. The programmed level and compliance are read back from the instrument and checked against the safety limits first. Confirm with the user that the DUT is connected and safe to energise. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
run_iv_sweep | ⚠️ hazard | Run a stepped IV sweep: configure the source, switch the output ON, step through the levels measuring V and I at each, then ALWAYS switch the output OFF (also on errors or when output_off is called). Returns the curve (downsampled), compliance flags, a linear fit and optional full CSV (a new file; an existing file is never overwritten). The output must be off beforehand. Limits are checked first. |
set_4wire | 🎛 control | Select 4-wire (remote sense, Kelvin) or 2-wire measurement. 4-wire removes lead resistance for low-resistance DUTs but needs the SENSE leads connected. Refused while the output is on. |
set_source_level | ⚠️ hazard | Change the level of the configured source. If the output is ON the new voltage/current is applied to the DUT immediately. The level and the present compliance are checked against the safety limits first. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
| Limit | Default | Meaning | ||
|---|---|---|---|---|
max_voltage_v | 20 V | Largest \ | voltage\ | an agent may source, or allow as voltage compliance |
max_current_a | 0.1 A | Largest \ | current\ | an agent may source, or allow as current compliance |
max_power_w | 2 W | Largest worst-case power \ | source level × compliance\ | |
max_sweep_points | 501 | Most points in one IV sweep (the return leg of a dual sweep counts) | ||
max_sweep_duration_s | 600 s | Longest estimated sweep duration (points × (delay + 2·NPLC/50 s + 20 ms)) |
The limits are checked before anything is sent: by configure_source and set_source_level, by run_iv_sweep (on the largest \|start\|, \|stop\|), and by output_on, which reads the programmed level and compliance back from the instrument. A level set on the front panel is therefore caught too. Requests beyond the model's own maximum (e.g. 40 V on a 2602B) are also refused. Override at launch: --limit max_voltage_v=60 --limit max_power_w=10. Tighten the defaults for fragile DUTs.
delay_s, take one reading, check compliance. Built-in instrument sweeps and trigger models are not used, so every point shows up in get_command_log. The output is switched off in a try/finally at the end of every sweep. Calling output_off while a sweep runs (even while it is still configuring) sets an abort flag and switches the output off at once; the sweep then stops without switching the output on again and reports aborted: true.max_sweep_duration_s, one sweep can take at most 1740 s (the tool's 30-minute timeout minus a margin): longer estimates are refused, and a sweep that runs slower than estimated stops early with the output off and returns the points measured so far (stop_reason says why)..csv and must not exist yet (an existing file is never overwritten); missing folders are created. It is checked before the output is switched on.null in the sweep curve, counted in overflow_points and left out of the statistics and the fit; measure reports them as an error.:SENS:FUNC:CONC ON, :SENS:FUNC "VOLT","CURR"), read with :READ? (:FORM:ELEM VOLT,CURR,STAT). Compliance comes from status-word bit 3.:READ? "defbuffer1",SOUR,READ returns both. Compliance comes from :SOUR:VOLT:ILIM:TRIP? / :SOUR:CURR:VLIM:TRIP?.print(smuX.measure.iv()) and print(smuX.source.compliance).In compliance, the reported V and I are the measured values, not the programmed level.
measure refuses to run when the output is off.configure_source and set_4wire refuse while the output is on. Use set_source_level (a hazard tool) to change a running source.limitp power compliance are not used.delay_s adds settling time per point.+802 "Not permitted with OUTPUT off", -222, -113; 2600B 1101 "Parameter too big", -285/-286). The exact message wording on real firmware may differ.| Model | Firmware | Interface | Verified by | Date |
|---|
| *none yet: [be the first](https://github.com/K-Dense-AI/lab-inst