World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
MCP server for Mettler Toledo laboratory balances (MT-SICS): weigh, tare, zero, log drift, adjust.
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 11/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 7/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 19/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install Mettler Toledo Balance. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-mettler-toledo.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Mettler Toledo Balance for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-mettler-toledo": { "command": "uvx", "args": [ "labmcp-mettler-toledo" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Mettler Toledo Balance tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-mettler-toledo": {
"command": "uvx",
"args": [
"labmcp-mettler-toledo"
]
}
}
}Use Mettler Toledo Balance and tell me what you can do for me, then show me one thing✓ If Claude says it is using Mettler Toledo Balance or shows a Mettler Toledo Balance tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect Mettler Toledo Balance yet
Mettler Toledo Balance runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect Mettler Toledo Balance
B · Others in Other that work with ChatGPT
Picked from the most used in the same category, only ones that connect by address with no key
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Mettler Toledo Balance for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-mettler-toledo -- uvx labmcp-mettler-toledo 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Mettler Toledo Balance tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-mettler-toledo -- uvx labmcp-mettler-toledoYou should see Mettler Toledo Balance listed as connected
Use Mettler Toledo Balance and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using Mettler Toledo Balance or shows a Mettler Toledo Balance tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Mettler Toledo Balance for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-mettler-toledo": { "command": "uvx", "args": [ "labmcp-mettler-toledo" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Mettler Toledo Balance tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Mettler Toledo Balance and tell me what you can do for me, then show me one thing✓ If Cursor says it is using Mettler Toledo Balance or shows a Mettler Toledo Balance tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Mettler Toledo Balance for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-mettler-toledo": { "type": "stdio", "command": "uvx", "args": [ "labmcp-mettler-toledo" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Mettler Toledo Balance tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Mettler Toledo Balance and tell me what you can do for me, then show me one thing✓ If VS Code says it is using Mettler Toledo Balance or shows a Mettler Toledo Balance tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-mettler-toledo -- uvx labmcp-mettler-toledoClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-mettler-toledo": {
"command": "uvx",
"args": [
"labmcp-mettler-toledo"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-mettler-toledo": {
"command": "uvx",
"args": [
"labmcp-mettler-toledo"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-mettler-toledo": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-mettler-toledo"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-mettler-toledoBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 20, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
No entries on OSV.dev for labmcp-mettler-toledo@0.1.3
Checks only this package version, not every dependency · checked Nov 16, 2026
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-mettler-toledo)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.3) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
Manage monitors, status pages, incidents and maintenances in your openstatus workspace.
Validate oh-my-posh configurations and segment snippets against the official schema.
MCP server for progressive tool usage at any scale (see https://klavis.ai)
Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.
| This one Mettler Toledo Balance | World Monitor | openstatus | Oh My Posh Validator | Strata | Jitsu | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install |
| Needs a key | No | No | No | No | No | No |
| Add with + in Claude | No | No | No | No | No | No |
| Basic checks | 3/3 | 4/4 | 4/4 | 4/4 | 1/4 | 4/4 |
| License | Apache-2.0 | AGPL-3.0 | AGPL-3.0 | MIT | Apache-2.0 | MIT |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent weigh samples, tare containers, log drift and evaporation, run internal adjustments and drive the draft shield on Mettler Toledo balances through the open MT-SICS interface command set.
| Package | labmcp-mettler-toledo |
| Instruments | Excellence XPR/XSR, XP/XS, XA/XE, MS/ML, NewClassic ME/MS, and other MT-SICS balances and weighing terminals |
| Interfaces | RS-232, USB (virtual COM port), Ethernet (XPR/XSR, or any serial-to-Ethernet adapter) |
| Protocol | MT-SICS levels 0–2 (reference manual) |
| Status | 🧪 simulated: tested against a wire-level MT-SICS simulator, not yet verified on hardware. Report a hardware test |
uvx labmcp-mettler-toledo --simulate --check
uvx labmcp ports uvx labmcp-mettler-toledo --address /dev/ttyUSB0 --check # Linux
uvx labmcp-mettler-toledo --address /dev/tty.usbserial-XXXX --check # macOS uvx labmcp-mettler-toledo --address COM4 --check # Windows uvx labmcp-mettler-toledo --address tcp://192.168.1.60:8001 --check # Ethernet
Non-default settings go in the address: `serial://COM4?baudrate=19200&xonxoff=false`.
Claude Code
claude mcp add balance -- uvx labmcp-mettler-toledo --address /dev/ttyUSB0
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "balance": { "command": "uvx", "args": ["labmcp-mettler-toledo", "--address", "/dev/ttyUSB0"] } } }
Add --read-only to allow weighing but block taring, zeroing and door movement. For other clients, generate the snippet with uvx labmcp config mettler-toledo --address /dev/ttyUSB0 --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
clear_tare | 🎛 control | Clear the tare memory (tare = 0). |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_draft_shield | 👁 read | Report the position of the motorised draft-shield doors (Excellence/XPR balances only). |
get_tare | 👁 read | Return the weight currently stored in the tare memory. |
log_weight_series | 👁 read | Record a series of immediate (unfiltered) readings to monitor drift, evaporation, moisture uptake or stabilisation. Returns every reading plus summary statistics. |
read_temperature | 👁 read | Read the balance's internal temperature probe(s) in °C (MT-SICS M28, if supported). |
read_weight | 👁 read | Read the current net weight from the balance. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
reset_balance | 🛑 safety | Abort whatever the balance is doing (an adjustment, a repeating weight stream, a pending command) and reset it to its power-on state without zeroing (MT-SICS @). Clears the tare. Motorised draft-shield doors have their own obstruction detection and reverse if blocked. |
run_internal_adjustment | 🎛 control | Adjust (calibrate) the balance with its built-in reference weight (MT-SICS C3). The pan must be empty and the balance undisturbed. Takes roughly 1-3 minutes. |
set_draft_shield | ⚠️ hazard | Open or close the motorised draft-shield doors. Make sure nothing (and no one's fingers) is in the way of the doors. |
set_tare_preset | 🎛 control | Preset a known tare weight (e.g. a container weighed earlier). |
show_message | 🎛 control | Show a short message on the balance display (e.g. 'Add sample 3'). Use show_weight_display to return to the normal weight display. |
show_weight_display | 🎛 control | Switch the balance display back to showing the weight. |
tare | 🎛 control | Tare the balance: store the current load (e.g. an empty container) as the tare weight. Returns the stored tare weight. |
zero | 🎛 control | Zero the balance with the current load. Also clears the tare memory. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server.
| Limit | Default | Meaning |
|---|---|---|
max_series_duration_s | 600 s | Longest weight-logging series an agent may start |
Override at launch: --limit max_series_duration_s=3600. Whatever the limit says, a single series is capped at one hour (the tool's time limit).
read_weight(stable=True) sends S, which waits for stability. If the balance cannot settle (draughts, vibration), it returns S I. The server reports this as an error, so retry or use stable=false.WS) and temperature (M28) commands exist only on balances with that hardware; other balances answer ES/L, which the server reports clearly.run_internal_adjustment waits for the final C3 A without blocking the connection: reset_balance aborts a running adjustment, and other commands are refused until it ends (their replies would be mixed up with the result).show_message accepts printable ASCII only, and set_tare_preset only a unit symbol: a line break would otherwise reach the balance as a second MT-SICS command.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |