Prototype · Preview: every server in the official registry, synced every 30 minutes. Sign in with Google to write reviews.Prototype · updated every 30 min
PopNx MCPMCP servers for people who use AI · explained in plain words

Opentrons OT-2 / Flex

by K-Dense-AIversion 0.1.3i★ 32 (Stars for the whole repo)iRuns on your computerRepository ↗
Registry nameio.github.K-Dense-AI/labmcp-opentrons

How to install

What it does

MCP server for Opentrons OT-2 and Flex liquid-handling robots (HTTP API).

  • Connects Runs on your computer
  • Account or key No key needed
  • Category Other

Why it ranks here

Lists are ordered by a usage score (out of 100) built from these parts

Popularity0/80GitHub stars or weekly downloads: the larger counts 60, the smaller 20
Freshness7/12Full marks for a release or code change within 30 days
Still answering0/8The cloud endpoint answered at the last check
Usage score7/100

Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)

Install

Pick the AI app you use, then copy the settings.

Let your AI install it with one sentence

Please install Opentrons OT-2 / Flex. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-opentrons.md, show me the commands and wait for my OK before running them.

Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads

Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026

First: which AI do you use?

Pick your app and the steps appear below.

Works with Claude, with some setup first

Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone

Let AI install it

Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Opentrons OT-2 / Flex for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-opentrons": { "command": "uvx", "args": [ "labmcp-opentrons" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Open the Claude desktop app’s settings file

    SettingsDeveloperEdit Config

  3. Paste these settings and save the file

    {
      "mcpServers": {
        "labmcp-opentrons": {
          "command": "uvx",
          "args": [
            "labmcp-opentrons"
          ]
        }
      }
    }
  4. Quit Claude and open it again

  5. Try it

    Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing

    ✓ If Claude says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version

ChatGPT cannot connect Opentrons OT-2 / Flex yet

Opentrons OT-2 / Flex runs on your computer, but ChatGPT can only connect servers that run on the web

What you can do instead

A · Use an app that can connect Opentrons OT-2 / Flex

  • Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
  • Install Python (uv) on your computer first (one time)
  • Install Python (uv) on your computer first (one time)
  • Install Python (uv) on your computer first (one time)

B · Others in Other that work with ChatGPT

Picked from the most used in the same category, only ones that connect by address with no key

Works with Claude Code, with some setup first

Install Python (uv) on your computer first (one time)

Let AI install it

Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Opentrons OT-2 / Flex for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-opentrons -- uvx labmcp-opentrons 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Open Terminal

    Mac: press Command+Space and type Terminal · Windows: open PowerShell

  3. Paste this command and press Enter

    claude mcp add --scope user labmcp-opentrons -- uvx labmcp-opentrons
  4. Type /mcp in Claude Code

    You should see Opentrons OT-2 / Flex listed as connected

  5. Try it

    Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing

    ✓ If Claude Code says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Works with Cursor, with some setup first

Install Python (uv) on your computer first (one time)

Let AI install it

Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Opentrons OT-2 / Flex for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-opentrons": { "command": "uvx", "args": [ "labmcp-opentrons" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Click this button to open Cursor

    Open in Cursor

    Cursor asks you to confirm; click Install

  3. Open the AI chat in Cursor in Agent mode

  4. Try it

    Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing

    ✓ If Cursor says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Works with VS Code, with some setup first

Install Python (uv) on your computer first (one time)

Let AI install it

Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Opentrons OT-2 / Flex for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-opentrons": { "type": "stdio", "command": "uvx", "args": [ "labmcp-opentrons" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Click this button to open VS Code

    Open in VS Code

    VS Code asks you to confirm; click Install

  3. Open the AI chat in VS Code in Agent mode

  4. Try it

    Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing

    ✓ If VS Code says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.

See every app that uses MCP →

JSON settings are under “For developers” below

Stuck? Ask people who use Opentrons OT-2 / Flex💬 Discussion →
For developers: Terminal commands and JSON settings

Installed on your computer

Claude Code

claude mcp add --scope user labmcp-opentrons -- uvx labmcp-opentrons

Claude Desktop (claude_desktop_config.json)

{
  "mcpServers": {
    "labmcp-opentrons": {
      "command": "uvx",
      "args": [
        "labmcp-opentrons"
      ]
    }
  }
}

Cursor (~/.cursor/mcp.json)

{
  "mcpServers": {
    "labmcp-opentrons": {
      "command": "uvx",
      "args": [
        "labmcp-opentrons"
      ]
    }
  }
}

VS Code (mcp.json)

{
  "servers": {
    "labmcp-opentrons": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-opentrons"
      ]
    }
  }
}

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

At a glance

GitHub starsi
32 (Stars for the whole repo)
This repo holds several MCP listings; its stars count once in rankings
Downloads per weeki
43/wk
Licencei
Apache-2.0
Connection
Runs on your computer
Latest versioni
0.1.3
Categoryi
Other
Published to registryi
Sep 27, 2026
Code last changedi
Sep 27, 2026
Maker
K-Dense-AI
Packages
pypi: labmcp-opentrons
Website
github.com
Registry status
Active

Which apps can use it

Based on how this server connects and on each app’s own docs, checked Nov 10, 2026.

Run on your computer in

ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast

All apps, with pros and cons →

Related guides

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • ✓ Pass

    Still maintained

    Code last changed 2 months ago

  • ✓ Pass

    Has a licence

    Uses Apache-2.0

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Published vulnerabilities (OSV.dev)

No entries on OSV.dev for labmcp-opentrons@0.1.3

Checks only this package version, not every dependency · checked Nov 16, 2026

What we check → · JSON

Makers: ask for a re-check or report wrong info
For makers: add a badge to your README

If you made this, paste this code into your README. The badge links back to this page.

[![Featured on PopNx MCP](https://mcp.popnx.com/badge/k-dense-ai-labmcp-opentrons.svg)](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-opentrons)

Discussion

Ask, share a tip or report that it does not work. Sorted by what people marked helpful.

No posts yet. Be the first to ask or share.

Posts here are written by users, not the PopNx team.

Sign in to post

User reviews

No reviews yet

Sign in to write a review

Compared with others in Otheri

  • More stars than 0% of the other 20693 servers in this category
  • Published to the registry more recently than 45% of the other 20693 servers in this category
  • Basic checks equal to or better than 99% of the other 20693 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Opentrons OT-2 / Flex safe?

It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed 2 months ago, and the latest version (0.1.3) reached the registry 2 months ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu

Similar alternatives

Same category, other makers, commands already checked. Official ones first, then by stars.

Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

World Monitor

Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.

by koala73Widely used★ 90.9KUpdated 3 days ago

Runs in the cloud✓ service owner · worldmonitor.app

openstatus

Manage monitors, status pages, incidents and maintenances in your openstatus workspace.

by openstatusHQWidely used★ 9.3KUpdated 2 months ago

Runs in the cloud✓ service owner · openstatus.dev

Oh My Posh Validator

Validate oh-my-posh configurations and segment snippets against the official schema.

by JanDeDobbeleerWidely used★ 23.8K Stars for the whole repoUpdated 30 days ago

Runs in the cloud✓ service owner · ohmyposh.dev

Strata

MCP server for progressive tool usage at any scale (see https://klavis.ai)

by Klavis-AIGrowing★ 5.8KUpdated 14 months ago

Runs in the cloudRepo archived✓ klavis.ai

Jitsu

Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.

by jitsucomWidely used★ 5.1KUpdated 4 months ago

Runs in the cloud✓ service owner · jitsu.com
Compared with similar ones
This one
Opentrons OT-2 / Flex
World MonitoropenstatusOh My Posh ValidatorStrataJitsu
Runs whereInstalls on your computerRuns in the cloud, nothing to installRuns in the cloud, nothing to installRuns in the cloud, nothing to installRuns in the cloud, nothing to installRuns in the cloud, nothing to install
Needs a keyNoNoNoNoNoNo
Add with + in ClaudeNoNoNoNoNoNo
Basic checks3/34/44/44/41/44/4
LicenseApache-2.0AGPL-3.0AGPL-3.0MITApache-2.0MIT
PriceNo cost listed in the registryNo cost listed in the registryNo cost listed in the registryNo cost listed in the registryNo cost listed in the registryNo cost listed in the registry

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Opentrons OT-2 / Flex — MCP Server

Let an AI agent upload and check protocols, review the deck layout with you, start, pause, stop and resume runs, follow their progress, and read pipettes and modules on Opentrons Flex and OT-2 liquid-handling robots through the robot's documented HTTP API.

Packagelabmcp-opentrons
InstrumentsOpentrons Flex, Opentrons OT-2 (robot software 5.1 or newer)
InterfacesEthernet, Wi-Fi, USB (network over USB)
ProtocolOpentrons robot-server HTTP API on port 31950, Opentrons-Version: 3 (HTTP API guide, robot-server source; every robot also serves its spec at http:// :31950/openapi.json and /redoc)
Status🧪 simulated: tested against an in-memory robot-server simulator, not yet verified on hardware. Report a hardware test

Why this server rather than a generic HTTP wrapper: it refuses to start a run unless the robot's own protocol analysis passed, the user has confirmed the deck, the door is closed, the E-stop is released and module setpoints are within your limits. It exposes no single-move pipetting commands, keeps pause and stop available even in read-only mode, and records every HTTP request in the command log.

Try it without hardware

uvx labmcp-opentrons --simulate --check

uvx labmcp-opentrons --simulate --option sim_model=ot2 --check # simulate an OT-2

The simulator runs protocols in memory: Python protocols are compiled and scanned for labware, pipettes, modules and steps, runs go through the real status lifecycle, and module temperatures respond to the protocol.

Connect your robot

  1. Find the IP address: Opentrons App > Devices > your robot > Robot settings > Networking (or on the Flex touchscreen: Settings > Network). The robot must be on the same network as the computer running the MCP server. USB-connected robots also get an IP address (OT-2: 169.254.x.x).
  2. Test the connection:
   uvx labmcp-opentrons --address 192.168.1.20 --check

uvx labmcp-opentrons --address http://ot2-lab.local:31950 --check

   `--check` prints the robot's name, model, software and firmware versions.
  1. Access control (Flex only, rarely needed): if your Flex has access control enabled and requests fail with HTTP 401, pass a token with --option access_token= .

Add to your MCP client

Claude Code

claude mcp add opentrons -- uvx labmcp-opentrons --address 192.168.1.20

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "opentrons": { "command": "uvx", "args": ["labmcp-opentrons", "--address", "192.168.1.20"] } } }

Add --read-only to let the agent monitor the robot (status, runs, protocols, modules) while blocking uploads, runs, homing and lights. pause_run, stop_run and deactivate_modules stay available. For other clients, generate the snippet with uvx labmcp config opentrons --address 192.168.1.20 --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
deactivate_modules🛑 safetySwitch attached modules off: stop heating/cooling (Temperature Module, Thermocycler block and lid, Heater-Shaker heater), stop shaking, and lower Magnetic Module magnets. Only possible when no run is in progress: stop the run first.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_protocol👁 readShow a stored protocol's analysis: whether it is ready to run, analysis errors, the deck layout it expects (labware and modules per slot, pipettes per mount, liquids), the number of steps and the highest module temperature / shake speed it requests. Review this with the user before start_run.
get_robot_status👁 readReport the robot's name, model (Flex/OT-2), software and firmware versions, lights, door and E-stop state, and the current run. Call this first to check the robot is ready.
get_run_status👁 readReport a run's status, the step it is on, progress, recent steps and any errors, plus advice on what to do next (e.g. when the run is waiting for error recovery).
home_robot⚠️ hazardHome all axes of the robot (the gantry and pipettes move to their home positions). Refused while a run is active. Make sure nothing is in the robot's path and the door is closed.
list_instruments👁 readList attached pipettes (and the Flex gripper): mount, name, channels, volume range, and whether a tip is detected and calibration data exists.
list_modules👁 readList attached modules (Temperature Module, Heater-Shaker, Thermocycler, Magnetic Module, Absorbance Plate Reader, ...) with live temperatures, targets, shake speed and status.
list_protocols👁 readList protocols stored on the robot (newest last) with their analysis status and result.
list_runs👁 readList recent protocol runs, newest first, with their status.
pause_run🛑 safetyPause a running protocol. The robot finishes its current step and then holds; resume_run continues it.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
resume_run⚠️ hazardResume a paused run (the robot starts moving again), or leave error recovery. Refused while the door is open. For a run awaiting recovery, error_recovery must be given.
set_lights🎛 controlTurn the robot's deck (rail) lights on or off.
start_run⚠️ hazardCreate a run of an analyzed protocol and start it: the robot begins moving and pipetting. Refused unless the protocol's analysis completed without errors, its module setpoints are within the safety limits, no other run is active, the door is closed and the E-stop is released.
stop_run🛑 safetyStop (cancel) a run immediately. A stopped run cannot be resumed; the robot homes and drops any attached tips into the trash. Use this whenever something looks wrong.
upload_protocol🎛 controlUpload a protocol file (plus optional custom labware) to the robot. The robot analyzes it (simulates it) and this tool returns the analysis: errors, deck layout and whether it is ready to run. Uploading does not move the robot. Uploading identical files returns the existing protocol.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. get_command_log shows every HTTP request sent to the robot and its reply.

Safety limits

LimitDefaultMeaning
max_module_temperature_c110 °CHighest temperature (Temperature Module, Thermocycler block or lid, Heater-Shaker) a protocol may request; start_run refuses protocols above it
max_shake_speed_rpm3000 rpmFastest Heater-Shaker speed a protocol may request

The defaults are the hardware maxima. Tighten them for heat-sensitive plastics or samples: --limit max_module_temperature_c=70 --limit max_shake_speed_rpm=1500. The check reads the setpoints from the robot's analysis of the protocol (every celsius and rpm value in module commands, including thermocycler profiles).

Other safety interlocks built into start_run:

  • the robot's analysis must have completed with result ok (pending, failed or parameter-required analyses are refused, and the errors are shown);
  • deck_confirmed=true is required, which the agent should only pass after you confirmed the deck matches the layout from get_protocol;
  • no other run may be active, the Flex door must be closed and the E-stop released.

Example prompts

  • "Upload ~/protocols/serial_dilution.py to the Flex and tell me whether the analysis passed. What labware do I need where?"
  • "The deck is set up as you listed. Start the serial dilution run and tell me when it's halfway."
  • "What is the robot doing right now? How many steps are left?"
  • "Pause the run — I need to top up the reservoir." … "OK, resume."
  • "The run says a tip is missing. I've refilled the tip rack in slot C2; continue the run."
  • "The PCR finished. Turn off the thermocycler and the heater-shaker, then switch the lights off."

Notes

  • Protocols, not single moves. This server runs complete protocols that the robot has analyzed. It deliberately has no tools for individual pipetting or gantry moves (POST /runs/{id}/commands), because without full deck state these can crash pipettes into labware. That may come later behind stricter checks.
  • Labware Position Check offsets are not applied. Runs created through the HTTP API do not include the offsets the Opentrons App applies from Labware Position Check. If your setup depends on them, start the run from the App, or set offsets in the protocol (labware.set_offset(...)).
  • Run-time parameters use their default values. Protocols that need a value this server cannot give (e.g. a CSV file parameter) are reported as not ready.
  • Stopping a run is final: the robot homes and drops tips in the trash. Pausing waits for the current step to finish.
  • Error recovery (recent robot software, mainly Flex): when a step fails (e.g. no tip detected), the run waits in awaiting-recovery. resume_run(error_recovery="continue") continues from the robot's actual state and skips the failed step; "assume_false_positive" treats the failure as a false alarm. Only use either after someone has checked the robot.
  • Modules stay on after a protocol ends unless the protocol switches them off. deactivate_modules sends the robot's stateless deactivate commands (POST /commands), which the robot only accepts when no run is in progress.
  • list_instruments uses GET /instruments, which the robot fully supports on Flex; on an OT-2 it returns pipettes with less detail (no calibration data).
  • The HTTP API version is pinned with the Opentrons-Version: 3 header, as in Opentrons' integration examples. Override with --option api_version=4 if needed.

Hardware verification

ModelRobot softwareInterfaceVerified byDate
*none yet: be the first*