World Monitor
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
MCP server for Opentrons OT-2 and Flex liquid-handling robots (HTTP API).
Lists are ordered by a usage score (out of 100) built from these parts
| Popularity | 0/80 | GitHub stars or weekly downloads: the larger counts 60, the smaller 20 |
|---|---|---|
| Freshness | 7/12 | Full marks for a release or code change within 30 days |
| Still answering | 0/8 | The cloud endpoint answered at the last check |
| Usage score | 7/100 |
Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)
Pick the AI app you use, then copy the settings.
Let your AI install it with one sentence
Please install Opentrons OT-2 / Flex. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-opentrons.md, show me the commands and wait for my OK before running them.Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads
Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026
First: which AI do you use?
Pick your app and the steps appear below.
Works with Claude, with some setup first
Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Opentrons OT-2 / Flex for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-opentrons": { "command": "uvx", "args": [ "labmcp-opentrons" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
SettingsDeveloperEdit Config
{
"mcpServers": {
"labmcp-opentrons": {
"command": "uvx",
"args": [
"labmcp-opentrons"
]
}
}
}Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing✓ If Claude says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
ChatGPT cannot connect Opentrons OT-2 / Flex yet
Opentrons OT-2 / Flex runs on your computer, but ChatGPT can only connect servers that run on the web
A · Use an app that can connect Opentrons OT-2 / Flex
B · Others in Other that work with ChatGPT
Picked from the most used in the same category, only ones that connect by address with no key
Works with Claude Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Opentrons OT-2 / Flex for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-opentrons -- uvx labmcp-opentrons 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Mac: press Command+Space and type Terminal · Windows: open PowerShell
claude mcp add --scope user labmcp-opentrons -- uvx labmcp-opentronsYou should see Opentrons OT-2 / Flex listed as connected
Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing✓ If Claude Code says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with Cursor, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Opentrons OT-2 / Flex for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-opentrons": { "command": "uvx", "args": [ "labmcp-opentrons" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing✓ If Cursor says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Works with VS Code, with some setup first
Install Python (uv) on your computer first (one time)
Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.
Please install the MCP server Opentrons OT-2 / Flex for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-opentrons": { "type": "stdio", "command": "uvx", "args": [ "labmcp-opentrons" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Opentrons OT-2 / Flex tools really show up.This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.
Already installed? Check first · Open Terminal, type this command and press Enter
uv --versionMac: press ⌘ + Space, type Terminal, press Enter
Windows: open Start, type Windows PowerShell, then Open
Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required
When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version
Install once; it works for everything that needs uv
Use Opentrons OT-2 / Flex and tell me what you can do for me, then show me one thing✓ If VS Code says it is using Opentrons OT-2 / Flex or shows a Opentrons OT-2 / Flex tool in the answer, you are connected
The command above works without these. Add them only if you want to change something, following the maker’s description.
LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)LABMCP_READ_ONLY Set to 1 to disable all state-changing toolsLABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80Descriptions are as written by the maker.
Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version
Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.
JSON settings are under “For developers” below
Claude Code
claude mcp add --scope user labmcp-opentrons -- uvx labmcp-opentronsClaude Desktop (claude_desktop_config.json)
{
"mcpServers": {
"labmcp-opentrons": {
"command": "uvx",
"args": [
"labmcp-opentrons"
]
}
}
}Cursor (~/.cursor/mcp.json)
{
"mcpServers": {
"labmcp-opentrons": {
"command": "uvx",
"args": [
"labmcp-opentrons"
]
}
}
}VS Code (mcp.json)
{
"servers": {
"labmcp-opentrons": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-opentrons"
]
}
}
}LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envDescriptions are as written by the maker.
These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.
pypi: labmcp-opentronsBased on how this server connects and on each app’s own docs, checked Nov 10, 2026.
Run on your computer in
ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast
Runs on your computer; the tool list appears in your AI app after you install it.
We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026
The registry name was verified with the GitHub account K-Dense-AI, which owns the repo
Code last changed 2 months ago
Uses Apache-2.0
This one runs on your computer; there is no internet endpoint
Runs on your computer and uses local settings instead
Runs on your computer; we can only read tool lists from internet endpoints
No entries on OSV.dev for labmcp-opentrons@0.1.3
Checks only this package version, not every dependency · checked Nov 16, 2026
If you made this, paste this code into your README. The badge links back to this page.
[](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-opentrons)Ask, share a tip or report that it does not work. Sorted by what people marked helpful.
No posts yet. Be the first to ask or share.
Posts here are written by users, not the PopNx team.
No reviews yet
Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.
It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.
The registry does not list a required key, though some servers ask you to sign in on first use.
It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).
The GitHub repo last changed 2 months ago, and the latest version (0.1.3) reached the registry 2 months ago.
Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.
In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu
Same category, other makers, commands already checked. Official ones first, then by stars.
Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi
Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.
Manage monitors, status pages, incidents and maintenances in your openstatus workspace.
Validate oh-my-posh configurations and segment snippets against the official schema.
MCP server for progressive tool usage at any scale (see https://klavis.ai)
Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.
| This one Opentrons OT-2 / Flex | World Monitor | openstatus | Oh My Posh Validator | Strata | Jitsu | |
|---|---|---|---|---|---|---|
| Runs where | Installs on your computer | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install | Runs in the cloud, nothing to install |
| Needs a key | No | No | No | No | No | No |
| Add with + in Claude | No | No | No | No | No | No |
| Basic checks | 3/3 | 4/4 | 4/4 | 4/4 | 1/4 | 4/4 |
| License | Apache-2.0 | AGPL-3.0 | AGPL-3.0 | MIT | Apache-2.0 | MIT |
| Price | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry | No cost listed in the registry |
Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.
Let an AI agent upload and check protocols, review the deck layout with you, start, pause, stop and resume runs, follow their progress, and read pipettes and modules on Opentrons Flex and OT-2 liquid-handling robots through the robot's documented HTTP API.
| Package | labmcp-opentrons |
| Instruments | Opentrons Flex, Opentrons OT-2 (robot software 5.1 or newer) |
| Interfaces | Ethernet, Wi-Fi, USB (network over USB) |
| Protocol | Opentrons robot-server HTTP API on port 31950, Opentrons-Version: 3 (HTTP API guide, robot-server source; every robot also serves its spec at http:// :31950/openapi.json and /redoc) |
| Status | 🧪 simulated: tested against an in-memory robot-server simulator, not yet verified on hardware. Report a hardware test |
Why this server rather than a generic HTTP wrapper: it refuses to start a run unless the robot's own protocol analysis passed, the user has confirmed the deck, the door is closed, the E-stop is released and module setpoints are within your limits. It exposes no single-move pipetting commands, keeps pause and stop available even in read-only mode, and records every HTTP request in the command log.
uvx labmcp-opentrons --simulate --check
uvx labmcp-opentrons --simulate --option sim_model=ot2 --check # simulate an OT-2
The simulator runs protocols in memory: Python protocols are compiled and scanned for labware, pipettes, modules and steps, runs go through the real status lifecycle, and module temperatures respond to the protocol.
169.254.x.x). uvx labmcp-opentrons --address 192.168.1.20 --check
uvx labmcp-opentrons --address http://ot2-lab.local:31950 --check
`--check` prints the robot's name, model, software and firmware versions.
--option access_token= .Claude Code
claude mcp add opentrons -- uvx labmcp-opentrons --address 192.168.1.20
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "opentrons": { "command": "uvx", "args": ["labmcp-opentrons", "--address", "192.168.1.20"] } } }
Add --read-only to let the agent monitor the robot (status, runs, protocols, modules) while blocking uploads, runs, homing and lights. pause_run, stop_run and deactivate_modules stay available. For other clients, generate the snippet with uvx labmcp config opentrons --address 192.168.1.20 --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
deactivate_modules | 🛑 safety | Switch attached modules off: stop heating/cooling (Temperature Module, Thermocycler block and lid, Heater-Shaker heater), stop shaking, and lower Magnetic Module magnets. Only possible when no run is in progress: stop the run first. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_protocol | 👁 read | Show a stored protocol's analysis: whether it is ready to run, analysis errors, the deck layout it expects (labware and modules per slot, pipettes per mount, liquids), the number of steps and the highest module temperature / shake speed it requests. Review this with the user before start_run. |
get_robot_status | 👁 read | Report the robot's name, model (Flex/OT-2), software and firmware versions, lights, door and E-stop state, and the current run. Call this first to check the robot is ready. |
get_run_status | 👁 read | Report a run's status, the step it is on, progress, recent steps and any errors, plus advice on what to do next (e.g. when the run is waiting for error recovery). |
home_robot | ⚠️ hazard | Home all axes of the robot (the gantry and pipettes move to their home positions). Refused while a run is active. Make sure nothing is in the robot's path and the door is closed. |
list_instruments | 👁 read | List attached pipettes (and the Flex gripper): mount, name, channels, volume range, and whether a tip is detected and calibration data exists. |
list_modules | 👁 read | List attached modules (Temperature Module, Heater-Shaker, Thermocycler, Magnetic Module, Absorbance Plate Reader, ...) with live temperatures, targets, shake speed and status. |
list_protocols | 👁 read | List protocols stored on the robot (newest last) with their analysis status and result. |
list_runs | 👁 read | List recent protocol runs, newest first, with their status. |
pause_run | 🛑 safety | Pause a running protocol. The robot finishes its current step and then holds; resume_run continues it. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
resume_run | ⚠️ hazard | Resume a paused run (the robot starts moving again), or leave error recovery. Refused while the door is open. For a run awaiting recovery, error_recovery must be given. |
set_lights | 🎛 control | Turn the robot's deck (rail) lights on or off. |
start_run | ⚠️ hazard | Create a run of an analyzed protocol and start it: the robot begins moving and pipetting. Refused unless the protocol's analysis completed without errors, its module setpoints are within the safety limits, no other run is active, the door is closed and the E-stop is released. |
stop_run | 🛑 safety | Stop (cancel) a run immediately. A stopped run cannot be resumed; the robot homes and drops any attached tips into the trash. Use this whenever something looks wrong. |
upload_protocol | 🎛 control | Upload a protocol file (plus optional custom labware) to the robot. The robot analyzes it (simulates it) and this tool returns the analysis: errors, deck layout and whether it is ready to run. Uploading does not move the robot. Uploading identical files returns the existing protocol. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. get_command_log shows every HTTP request sent to the robot and its reply.
| Limit | Default | Meaning |
|---|---|---|
max_module_temperature_c | 110 °C | Highest temperature (Temperature Module, Thermocycler block or lid, Heater-Shaker) a protocol may request; start_run refuses protocols above it |
max_shake_speed_rpm | 3000 rpm | Fastest Heater-Shaker speed a protocol may request |
The defaults are the hardware maxima. Tighten them for heat-sensitive plastics or samples: --limit max_module_temperature_c=70 --limit max_shake_speed_rpm=1500. The check reads the setpoints from the robot's analysis of the protocol (every celsius and rpm value in module commands, including thermocycler profiles).
Other safety interlocks built into start_run:
ok (pending, failed or parameter-required analyses are refused, and the errors are shown);deck_confirmed=true is required, which the agent should only pass after you confirmed the deck matches the layout from get_protocol;~/protocols/serial_dilution.py to the Flex and tell me whether the analysis passed. What labware do I need where?"POST /runs/{id}/commands), because without full deck state these can crash pipettes into labware. That may come later behind stricter checks.labware.set_offset(...)).awaiting-recovery. resume_run(error_recovery="continue") continues from the robot's actual state and skips the failed step; "assume_false_positive" treats the failure as a false alarm. Only use either after someone has checked the robot.deactivate_modules sends the robot's stateless deactivate commands (POST /commands), which the robot only accepts when no run is in progress.list_instruments uses GET /instruments, which the robot fully supports on Flex; on an OT-2 it returns pipettes with less detail (no calibration data).Opentrons-Version: 3 header, as in Opentrons' integration examples. Override with --option api_version=4 if needed.| Model | Robot software | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |