Prototype · Preview: every server in the official registry, synced every 30 minutes. Sign in with Google to write reviews.Prototype · updated every 30 min
PopNx MCPMCP servers for people who use AI · explained in plain words

Pfeiffer Vacuum Gauge Controller

by K-Dense-AIversion 0.1.2i★ 32 (Stars for the whole repo)iRuns on your computerRepository ↗
Registry nameio.github.K-Dense-AI/labmcp-pfeiffer-tpg

How to install

What it does

MCP server for Pfeiffer Vacuum TPG 361/362/366 and TPG 261/262 gauge controllers.

  • Connects Runs on your computer
  • Account or key No key needed
  • Category Other

Why it ranks here

Lists are ordered by a usage score (out of 100) built from these parts

Popularity0/80GitHub stars or weekly downloads: the larger counts 60, the smaller 20
Freshness7/12Full marks for a release or code change within 30 days
Still answering0/8The cloud endpoint answered at the last check
Usage score7/100

Quality: Passed 3/3 basic checks (shown, not used for ordering) · Momentum: No data yet (Used only on the Trending tab)

Install

Pick the AI app you use, then copy the settings.

Let your AI install it with one sentence

Please install Pfeiffer Vacuum Gauge Controller. Follow https://mcp.popnx.com/i/k-dense-ai-labmcp-pfeiffer-tpg.md, show me the commands and wait for my OK before running them.

Paste it into an AI that can work on your computer (such as Claude Code or Cursor). It reads our steps, shows you the commands and waits for your OK. No key, no sign-up. · See the full text your AI reads

Passed 3/3 checks · Runs on your computer · ✓ Commands checked Nov 14, 2026

First: which AI do you use?

Pick your app and the steps appear below.

Works with Claude, with some setup first

Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone

Let AI install it

Copy this message into a Claude chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Pfeiffer Vacuum Gauge Controller for Claude on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-pfeiffer-tpg": { "command": "uvx", "args": [ "labmcp-pfeiffer-tpg" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Pfeiffer Vacuum Gauge Controller tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Open the Claude desktop app’s settings file

    SettingsDeveloperEdit Config

  3. Paste these settings and save the file

    {
      "mcpServers": {
        "labmcp-pfeiffer-tpg": {
          "command": "uvx",
          "args": [
            "labmcp-pfeiffer-tpg"
          ]
        }
      }
    }
  4. Quit Claude and open it again

  5. Try it

    Use Pfeiffer Vacuum Gauge Controller and tell me what you can do for me, then show me one thing

    ✓ If Claude says it is using Pfeiffer Vacuum Gauge Controller or shows a Pfeiffer Vacuum Gauge Controller tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version

ChatGPT cannot connect Pfeiffer Vacuum Gauge Controller yet

Pfeiffer Vacuum Gauge Controller runs on your computer, but ChatGPT can only connect servers that run on the web

What you can do instead

A · Use an app that can connect Pfeiffer Vacuum Gauge Controller

  • Install Python (uv) on your computer first (one time) · Only the Claude desktop app (Windows or Mac), not the web or phone
  • Install Python (uv) on your computer first (one time)
  • Install Python (uv) on your computer first (one time)
  • Install Python (uv) on your computer first (one time)

B · Others in Other that work with ChatGPT

Picked from the most used in the same category, only ones that connect by address with no key

Works with Claude Code, with some setup first

Install Python (uv) on your computer first (one time)

Let AI install it

Copy this message into a Claude Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Pfeiffer Vacuum Gauge Controller for Claude Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): claude mcp add --scope user labmcp-pfeiffer-tpg -- uvx labmcp-pfeiffer-tpg 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Pfeiffer Vacuum Gauge Controller tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Open Terminal

    Mac: press Command+Space and type Terminal · Windows: open PowerShell

  3. Paste this command and press Enter

    claude mcp add --scope user labmcp-pfeiffer-tpg -- uvx labmcp-pfeiffer-tpg
  4. Type /mcp in Claude Code

    You should see Pfeiffer Vacuum Gauge Controller listed as connected

  5. Try it

    Use Pfeiffer Vacuum Gauge Controller and tell me what you can do for me, then show me one thing

    ✓ If Claude Code says it is using Pfeiffer Vacuum Gauge Controller or shows a Pfeiffer Vacuum Gauge Controller tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Anthropic’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Works with Cursor, with some setup first

Install Python (uv) on your computer first (one time)

Let AI install it

Copy this message into a Cursor chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Pfeiffer Vacuum Gauge Controller for Cursor on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "mcpServers": { "labmcp-pfeiffer-tpg": { "command": "uvx", "args": [ "labmcp-pfeiffer-tpg" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Pfeiffer Vacuum Gauge Controller tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Click this button to open Cursor

    Open in Cursor

    Cursor asks you to confirm; click Install

  3. Open the AI chat in Cursor in Agent mode

  4. Try it

    Use Pfeiffer Vacuum Gauge Controller and tell me what you can do for me, then show me one thing

    ✓ If Cursor says it is using Pfeiffer Vacuum Gauge Controller or shows a Pfeiffer Vacuum Gauge Controller tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against Cursor’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Works with VS Code, with some setup first

Install Python (uv) on your computer first (one time)

Let AI install it

Copy this message into a VS Code chat. The AI checks your computer, tells you which file it will change, and waits for your OK every time.

Please install the MCP server Pfeiffer Vacuum Gauge Controller for VS Code on this computer, in this order: 1) Check uv with uv --version. If it is missing, tell me to install it from https://docs.astral.sh/uv/getting-started/installation/; do not install it yourself. 2) Use only this config (already checked by PopNx MCP): { "servers": { "labmcp-pfeiffer-tpg": { "type": "stdio", "command": "uvx", "args": [ "labmcp-pfeiffer-tpg" ] } } } 3) Tell me the full path of the file you will change, or the command you will run, and wait for my OK. 4) No key is needed. 5) Do what we agreed, then check that the Pfeiffer Vacuum Gauge Controller tools really show up.

This message has no key in it. If a key is needed, the AI will ask you to paste it yourself into the file or the app’s field.

  1. Install uv (if you don’t have it)

    Already installed? Check first · Open Terminal, type this command and press Enter

    uv --version
    • A version number such as uv … = installed, skip this step
    • "command not found" (on Windows: "is not recognized") = not installed yet, or installed but Terminal needs to be closed and reopened
    How to open Terminal

    Mac: press ⌘ + Space, type Terminal, press Enter

    Windows: open Start, type Windows PowerShell, then Open

    Not installed: uv has no click-through installer. Copy the one-line command for your system (macOS or Windows) from uv’s official page into Terminal · no separate Python install needed; uv downloads it when required

    Open the uv download page ↗

    When it’s done, close Terminal, open it again and run the same command. You should see a version number: uv --version

    Install once; it works for everything that needs uv

  2. Click this button to open VS Code

    Open in VS Code

    VS Code asks you to confirm; click Install

  3. Open the AI chat in VS Code in Agent mode

  4. Try it

    Use Pfeiffer Vacuum Gauge Controller and tell me what you can do for me, then show me one thing

    ✓ If VS Code says it is using Pfeiffer Vacuum Gauge Controller or shows a Pfeiffer Vacuum Gauge Controller tool in the answer, you are connected

4 optional setting(s) (works without them)

The command above works without these. Add them only if you want to change something, following the maker’s description.

  • LABMCP_ADDRESS Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

Menu names checked against VS Code’s help page on Nov 11, 2026 · your screen may differ slightly by app version

Other apps that use MCP, such as Windsurf, Zed or Gemini CLI, each add servers differently. See how in the app list.

See every app that uses MCP →

JSON settings are under “For developers” below

Stuck? Ask people who use Pfeiffer Vacuum Gauge Controller💬 Discussion →
For developers: Terminal commands and JSON settings

Installed on your computer

Claude Code

claude mcp add --scope user labmcp-pfeiffer-tpg -- uvx labmcp-pfeiffer-tpg

Claude Desktop (claude_desktop_config.json)

{
  "mcpServers": {
    "labmcp-pfeiffer-tpg": {
      "command": "uvx",
      "args": [
        "labmcp-pfeiffer-tpg"
      ]
    }
  }
}

Cursor (~/.cursor/mcp.json)

{
  "mcpServers": {
    "labmcp-pfeiffer-tpg": {
      "command": "uvx",
      "args": [
        "labmcp-pfeiffer-tpg"
      ]
    }
  }
}

VS Code (mcp.json)

{
  "servers": {
    "labmcp-pfeiffer-tpg": {
      "type": "stdio",
      "command": "uvx",
      "args": [
        "labmcp-pfeiffer-tpg"
      ]
    }
  }
}

Values you fill in

  • LABMCP_ADDRESS env
    Instrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
  • LABMCP_SIMULATE env
    Set to 1 to use the built-in simulator (no hardware)
  • LABMCP_READ_ONLY env
    Set to 1 to disable all state-changing tools
  • LABMCP_LIMITS env
    Safety limit overrides, e.g. max_temperature_c=80

Descriptions are as written by the maker.

These settings are generated from the maker’s registry entry. If the README says otherwise, follow the README.

At a glance

GitHub starsi
32 (Stars for the whole repo)
This repo holds several MCP listings; its stars count once in rankings
Downloads per weeki
32/wk
Licencei
Apache-2.0
Connection
Runs on your computer
Latest versioni
0.1.2
Categoryi
Other
Published to registryi
Sep 27, 2026
Code last changedi
Sep 27, 2026
Maker
K-Dense-AI
Packages
pypi: labmcp-pfeiffer-tpg
Website
github.com
Registry status
Active

Which apps can use it

Based on how this server connects and on each app’s own docs, checked Nov 10, 2026.

Run on your computer in

ClaudeGooseLM StudioMsty StudioCherry StudioCursorVS Code + GitHub CopilotVisual StudioWindsurf (Devin Desktop)ZedKiroClineContinueJetBrains AI AssistantClaude CodeCodex CLIGemini CLIOpenCodenodecodeWarpLibreChatRaycast

All apps, with pros and cons →

Related guides

What it can do

Runs on your computer; the tool list appears in your AI app after you install it.

Basic checksi

We check information anyone can see; we have not read the code. Checks that do not apply are left out of the count. · Checked Nov 19, 2026

  • ✓ Pass

    Maker matches the repo

    The registry name was verified with the GitHub account K-Dense-AI, which owns the repo

  • ✓ Pass

    Still maintained

    Code last changed 2 months ago

  • ✓ Pass

    Has a licence

    Uses Apache-2.0

  • – Not applicable

    Endpoint responds

    This one runs on your computer; there is no internet endpoint

  • – Not applicable

    Sign-in with OAuth

    Runs on your computer and uses local settings instead

  • … Not checked yet

    No hidden instructions in tool descriptions

    Runs on your computer; we can only read tool lists from internet endpoints

Published vulnerabilities (OSV.dev)

No entries on OSV.dev for labmcp-pfeiffer-tpg@0.1.2

Checks only this package version, not every dependency · checked Nov 16, 2026

What we check → · JSON

Makers: ask for a re-check or report wrong info
For makers: add a badge to your README

If you made this, paste this code into your README. The badge links back to this page.

[![Featured on PopNx MCP](https://mcp.popnx.com/badge/k-dense-ai-labmcp-pfeiffer-tpg.svg)](https://mcp.popnx.com/en/servers/k-dense-ai-labmcp-pfeiffer-tpg)

Discussion

Ask, share a tip or report that it does not work. Sorted by what people marked helpful.

No posts yet. Be the first to ask or share.

Posts here are written by users, not the PopNx team.

Sign in to post

User reviews

No reviews yet

Sign in to write a review

Compared with others in Otheri

  • More stars than 0% of the other 20653 servers in this category
  • Published to the registry more recently than 45% of the other 20653 servers in this category
  • Basic checks equal to or better than 99% of the other 20653 servers in this category

Compared with every active server in this category in the registry. Stars count only when the publisher owns the repo.

Common questions

Is Pfeiffer Vacuum Gauge Controller safe?

It passed 3 of 3 applicable basic checks. We have not read the code. Before adding a key or token, see what access the server asks for and use a key with only the permissions you need.

What keys or codes does it need?

The registry does not list a required key, though some servers ask you to sign in on first use.

Does it run on my computer or in the cloud?

It runs on your computer. Your AI app starts it when needed, and data does not pass through the maker’s servers (unless it calls an online service itself).

Is it still maintained?

The GitHub repo last changed 2 months ago, and the latest version (0.1.2) reached the registry 2 months ago.

Which apps can use it?

Apps that support MCP, such as Claude Desktop, Claude Code, Cursor and VS Code. You also need Python (uv) on your computer.

What can I use instead?

In the same category: World Monitor, openstatus, Oh My Posh Validator, Strata, Jitsu

Similar alternatives

Same category, other makers, commands already checked. Official ones first, then by stars.

Reading a card:↓ Downloads per weeki★ GitHub starsiThree pillars: reviews · checks · usageiUpdated = latest version published to the registryi

World Monitor

Real-time global intelligence on conflict, markets, energy, trade, shipping and cyber. 100 tools.

by koala73Widely used★ 90.9KUpdated 3 days ago

Runs in the cloud✓ service owner · worldmonitor.app

openstatus

Manage monitors, status pages, incidents and maintenances in your openstatus workspace.

by openstatusHQWidely used★ 9.3KUpdated 2 months ago

Runs in the cloud✓ service owner · openstatus.dev

Oh My Posh Validator

Validate oh-my-posh configurations and segment snippets against the official schema.

by JanDeDobbeleerWidely used★ 23.8K Stars for the whole repoUpdated 30 days ago

Runs in the cloud✓ service owner · ohmyposh.dev

Strata

MCP server for progressive tool usage at any scale (see https://klavis.ai)

by Klavis-AIGrowing★ 5.8KUpdated 14 months ago

Runs in the cloudRepo archived✓ klavis.ai

Jitsu

Manage Jitsu data pipelines: destinations, streams, connections, functions, live events.

by jitsucomWidely used★ 5.1KUpdated 4 months ago

Runs in the cloud✓ service owner · jitsu.com
Compared with similar ones
This one
Pfeiffer Vacuum Gauge Controller
World MonitoropenstatusOh My Posh ValidatorStrataJitsu
Runs whereInstalls on your computerRuns in the cloud, nothing to installRuns in the cloud, nothing to installRuns in the cloud, nothing to installRuns in the cloud, nothing to installRuns in the cloud, nothing to install
Needs a keyNoNoNoNoNoNo
Add with + in ClaudeNoNoNoNoNoNo
Basic checks3/34/44/44/41/44/4
LicenseApache-2.0AGPL-3.0AGPL-3.0MITApache-2.0MIT
PriceNo cost listed in the registryNo cost listed in the registryNo cost listed in the registryNo cost listed in the registryNo cost listed in the registryNo cost listed in the registry

README from the maker

Open the README

Copied from the maker’s repo as written. PopNx MCP has not reviewed or endorsed it. HTML, images and scripts are removed. Links lead off this site.

Pfeiffer Vacuum Gauge Controller — MCP Server

Let an AI agent read and log chamber and foreline pressures, identify the connected gauges, change the pressure unit and switch ionisation gauges on and off (with a pressure check) on Pfeiffer Vacuum TPG total-pressure gauge controllers.

Packagelabmcp-pfeiffer-tpg
InstrumentsTPG 361 SingleGauge, TPG 362 DualGauge, TPG 366 MaxiGauge (ActiveLine gauges); TPG 261 / TPG 262 (compact gauges)
InterfacesTPG 36x: USB type B (virtual COM port), Ethernet (TCP port 8000); TPG 26x: RS-232
ProtocolPfeiffer mnemonics protocol, ACK/NAK + ENQ (TPG 361/362 communication protocol BG 5510 BEN, TPG 366 communication protocol BG 5511 BEN, TPG 262 operating instructions BG 805 196 BE section 5; originals in the Pfeiffer download center)
Status🧪 simulated: tested against a byte-level simulator of the protocol, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-pfeiffer-tpg --simulate --check                      # TPG 362: FullRange gauge + Pirani

uvx labmcp-pfeiffer-tpg --simulate --option model=tpg366 --check # 6 channels incl. a cold cathode gauge

The simulated chamber pumps down from 8e-5 mbar towards 2e-7 mbar (10 min time constant) and the foreline sits at about 2.4e-2 mbar.

Connect your controller

  1. Protocol (TPG 36x): the *PROTOCOL* parameter must be *AUTO* (factory setting) or *MNE* (mnemonics), not *PV* (Pfeiffer Vacuum telegram protocol).
  2. USB (TPG 36x): the USB type B port appears as a virtual COM port. Factory setting 9600 baud, 8N1 (parameter *BAUD USB*; 19200-115200 also possible).
  3. Ethernet (TPG 36x, TPG 366): set DHCP or a static IP (front panel or Pfeiffer's Ethernet Configuration Tool); the command port is fixed at 8000.
  4. RS-232 (TPG 261/262): 9600 baud 8N1 by default, only TXD/RXD used.
  5. Test the connection:
   uvx labmcp-pfeiffer-tpg --address /dev/ttyUSB0 --check

uvx labmcp-pfeiffer-tpg --address COM3 --check uvx labmcp-pfeiffer-tpg --address "serial://COM3?baudrate=115200" --check uvx labmcp-pfeiffer-tpg --address tcp://192.168.1.70:8000 --check

   The model is detected with `AYT` (TPG 36x); a controller that does not know `AYT` is treated as a TPG 26x. Use `--option model=tpg261` (or `tpg262`, `tpg361`, `tpg362`, `tpg366`) to be explicit.

Add to your MCP client

Claude Code

claude mcp add vacuum -- uvx labmcp-pfeiffer-tpg --address tcp://192.168.1.70:8000

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{

"mcpServers": { "vacuum": { "command": "uvx", "args": ["labmcp-pfeiffer-tpg", "--address", "tcp://192.168.1.70:8000"] } } }

Add --read-only to allow reading and logging but block unit changes and switching gauges on (switch_gauge_off stays available). For other clients, generate the snippet with uvx labmcp config pfeiffer-tpg --address tcp://192.168.1.70:8000 --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_errors👁 readRead (and clear) the controller's ERROR word: controller error, no hardware, inadmissible parameter or syntax error. An empty list means no error.
get_gauge_types👁 readList the gauge connected to each channel (TID), what kind it is, and whether it is an ionisation gauge that is currently switched on or off (SEN).
log_pressure_series👁 readLog pressures at a fixed interval (e.g. a pump-down curve, leak-up/rate-of-rise test or bake-out). Returns per-channel statistics in log-space plus a downsampled series; the full series can be written to a new CSV file (an existing file is never overwritten). Bounded by max_log_duration_s and 2 h per call.
read_all_pressures👁 readRead every channel of the controller at once (PRX), with status per channel.
read_pressure👁 readRead one gauge channel: status, pressure in the display unit and in mbar.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_gauge_power⚠️ hazardSwitch an ionisation gauge (IKR, PKR, PBR, IMR) on or off (SEN). Switching a hot or cold cathode gauge on at high pressure can burn out the filament or contaminate the gauge, so switching ON is refused unless a valid reading from this gauge or reference_channel is at or below max_switch_on_pressure_mbar. Switching off may trip setpoint relays used as interlocks.
set_unit🎛 controlChange the pressure unit used on the display and interface (UNI). Readings in mbar are always included regardless of this setting.
switch_gauge_off🛑 safetySwitch an ionisation gauge off (e.g. before venting, or if the pressure is rising). Always allowed. Note that setpoint relays assigned to this channel may change state.

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

LimitDefaultMeaning
max_switch_on_pressure_mbar1e-2 mbarAn ionisation gauge may only be switched on when a valid reading (its own, or reference_channel) is at or below this pressure
max_log_duration_s3600 sLongest log_pressure_series an agent may start

Override at launch: --limit max_switch_on_pressure_mbar=1e-3 --limit max_log_duration_s=7200. One log_pressure_series call logs at most 2 h (the tool's timeout); for a longer bake-out, log in consecutive calls to separate files. save_path must end in .csv and must not exist yet (an existing file is never overwritten); it is checked before logging starts.

Example prompts

  • "What's the chamber pressure right now, and is the foreline below 5e-2 mbar?"
  • "Log all gauges every 10 s for 30 minutes and tell me how many decades per minute the chamber is pumping down."
  • "Close the valve, then log channel 1 every 2 s for 5 minutes so I can estimate the leak-up rate."
  • "Which gauges are connected, and which ones are ionisation gauges that are switched off?"
  • "The chamber is below 1e-5 mbar on the FullRange gauge - switch on the cold cathode gauge on channel 3, using channel 1 as the reference."

Notes

  • Switching ionisation gauges on is the hazard. Hot-cathode (Bayard-Alpert) filaments can burn out and cold-cathode (Penning) gauges contaminate when operated at high pressure. set_gauge_power(on=True) requires a reading with status *ok* at or below max_switch_on_pressure_mbar from the gauge itself or from reference_channel on the same vacuum. An *underrange* reading from a Pirani is not accepted as proof (what the controller reports on underrange is not specified), so in a Pirani + Penning setup switch the Penning on at the controller, or use a FullRange gauge as the reference. The 1e-2 mbar default is the upper end of a typical cold cathode measuring range; check your gauge's manual and lower it for hot-filament gauges if recommended.
  • Switching a gauge off (switch_gauge_off, or set_gauge_power(on=False)) can change setpoint (switching-function) relays assigned to that channel, which may be wired to valve or pump interlocks.
  • Every pressure comes with the controller's status: *ok*, *underrange*, *overrange*, *sensor error*, *sensor off*, *no sensor* or *identification error*. pressure is only filled in when the status is *ok*; raw_value is what the controller sent. Values are converted to mbar (1 Torr = 1.333224 mbar); in *V* mode no conversion is made.
  • Every command waits for ACK/NAK; after a NAK the ERROR word (controller error, no hardware, inadmissible parameter, syntax error) is read and reported. get_errors reads and clears it.
  • Degas, filter, calibration factors, switching-function setpoints, gauge control (hot start/self control), the data logger and the Pfeiffer Vacuum (PV) telegram protocol are not exposed. RS-485 multi-drop operation has not been tested.

Hardware verification

ModelFirmwareInterfaceVerified byDate
*none yet: be the first*