Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
作者による説明(英語の原文)
MCP server that builds and validates LC-MS worklists for MassLynx, SCIEX OS, MassHunter, Xcalibur.
この3つを1つのスコアにまとめることはしません。意見、測定、人気はそれぞれ別のものだからです。
このサーバーのやさしい解説はまだ書いていません。以下はレジストリから読み取った事実です。
使っているAIアプリを選んで、設定をコピーしてください。
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS必要なもの
どのアプリを使っていますか?
上でアプリを選んでください。選んだアプリを覚えておくので、次からはボタンに「…にインストール」と表示されます。
Claude Desktop → Settings → Developer → Edit Config を開き、claude_desktop_config.json にこれを貼り付けます
{
"mcpServers": {
"labmcp-ms-worklist": {
"command": "uvx",
"args": [
"labmcp-ms-worklist"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}ターミナルでこれを実行します
claude mcp add labmcp-ms-worklist --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-ms-worklist動かす前に、空欄の値を入力してください。
プロジェクトの .cursor/mcp.json、または ~/.cursor/mcp.json に貼り付けます
{
"mcpServers": {
"labmcp-ms-worklist": {
"command": "uvx",
"args": [
"labmcp-ms-worklist"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}ブラウザがアプリを開いてよいか確認し、そのあとアプリが設定を表示して確認を求めます。キーの値は空欄のままなので、自分で入力してください。
プロジェクトの .vscode/mcp.json に貼り付けます
{
"servers": {
"labmcp-ms-worklist": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-ms-worklist"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}ブラウザがアプリを開いてよいか確認し、そのあとアプリが設定を表示して確認を求めます。キーの値は空欄のままなので、自分で入力してください。
これはパソコンで動くサーバーですが、ChatGPTがつなげるのはインターネット上のサーバーだけです。ほかのアプリを選んでください。
選んだアプリは、この端末のCookieに保存されます。アカウントは不要です。
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS envこの設定は、作者のレジストリ登録情報から作成しています。READMEと違う場合は、READMEに従ってください。
パソコンで動くサーバーです。インストールすると、ツール一覧がAIアプリに表示されます。
誰でも見られる情報をチェックしており、コードは読んでいません。当てはまらない項目は数に入れていません。 · 2026年11月8日にチェック
レジストリ名は、リポジトリを所有するGitHubアカウント K-Dense-AI で確認済みです
このリポジトリはまだGitHubから読み取っていません
このリポジトリはまだGitHubから読み取っていません
これはパソコンで動くため、インターネット上のエンドポイントはありません
パソコンで動き、代わりにローカルの設定を使います
パソコンで動くサーバーです。ツール一覧を読み取れるのは、インターネット上のエンドポイントがある場合だけです
レジストリでこのカテゴリにある有効なすべてのサーバーと比較しています。スターは、公開者がリポジトリの所有者である場合だけ数えます。
当てはまる基本チェック1項目のうち1項目に合格しました。コードは読んでいません。キーやトークンを追加する前に、サーバーがどんなアクセスを求めているかを確認し、必要な権限だけを持つキーを使ってください。
レジストリには必須のキーは載っていません。ただし、最初に使うときにサインインを求めるサーバーもあります。
あなたのパソコンで動きます。必要なときにAIアプリが起動し、データは作者のサーバーを通りません(サーバー自体がオンラインサービスを呼び出す場合を除きます)。
GitHubリポジトリの最終更新は–、最新バージョン(0.1.1)がレジストリに届いたのは42 日前です。
Claude Desktop、Claude Code、Cursor、VS CodeなどのMCP対応アプリで使えます。パソコンにPython (uv)も必要です。
同じカテゴリには:Spec Driven Development, Remote Desktop Commander, Happo
同じカテゴリで、ほかの作者が作ったサーバー。スターの多い順。
カードの見方:★ GitHubスターi3つの柱:レビュー · チェック · 利用状況i更新=最新バージョンをレジストリに公開した日i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
Review Happo's visual and accessibility diffs: inspect comparisons, accept or reject, report flakes.
作者のリポジトリから書かれたとおりにコピーしたものです。PopNx MCPは内容を確認・推奨していません。HTML、画像、スクリプトは取り除いています。リンクはこのサイトの外へ移動します。
Let an AI agent build LC-MS sample queues (worklists, sequences, batches) and export them as import files for Waters MassLynx, SCIEX OS, Agilent MassHunter Acquisition and Thermo Xcalibur. The agent can lay out samples on a tray, insert blanks and QCs, randomise the run order with a recorded seed, check the list for mistakes, convert an existing file from one vendor to another, and write the file for a person to import. It uses only documented import formats. It never starts an acquisition and doesn't talk to the mass spectrometer.
| Package | labmcp-ms-worklist |
| Software | Waters MassLynx 4.x, SCIEX OS, Agilent MassHunter Acquisition (LC/TQ, LC/Q-TOF), Thermo Xcalibur 2.2+ |
| Interfaces | File (writes CSV/TXT import files into one output folder) |
| Protocol | Vendor sample-list import formats (see Formats for sources) |
| Status | 🧪 simulated: tested with golden files and round-trip tests, not yet imported into the vendor software by us. Report a test |
uvx labmcp-ms-worklist --simulate --check
--simulate uses a temporary output folder that is deleted when the server stops. Everything else is the same code.
The "instrument address" is the output folder where worklist files are written (default ./worklists, created if missing):
uvx labmcp-ms-worklist --address "D:\Worklists" --check # Windows acquisition PC or a shared drive
uvx labmcp-ms-worklist --address ~/lcms/worklists --check # macOS / Linux, then copy the files over
.., absolute paths elsewhere and symlinks that point outside it. It never overwrites an existing file unless the agent passes overwrite=true.--address at a folder the acquisition software watches only if the vendor documents that behaviour for your setup. Otherwise import the file by hand (instructions below).Claude Code
claude mcp add ms-worklist -- uvx labmcp-ms-worklist --address ~/lcms/worklists
Claude Desktop / Cursor / Windsurf
{
"mcpServers": { "ms-worklist": { "command": "uvx", "args": ["labmcp-ms-worklist", "--address", "/path/to/worklists"] } } }
--read-only keeps only the tools that inspect things (list_formats, validate_worklist, import_worklist, get_worklist, list_worklists).
| Tool | Kind | Description |
|---|---|---|
add_samples | 🎛 control | Append samples to a draft worklist (the worklist's defaults and automatic positions apply; any blank/QC/randomisation plan is re-applied to the longer list with the same seed). |
create_worklist | 🎛 control | Create an in-memory draft worklist from a sample list plus defaults (methods, injection volume, tray positions, data-file naming pattern). Nothing is written to disk until export_worklist. Injection volumes above the max_injection_volume_ul limit are refused. |
export_worklist | 🎛 control | Validate the draft and write the vendor import file into the output folder. Returns the path, a preview of the first lines, warnings and import instructions. Refuses if validation finds errors or the file exists (unless overwrite=true). This does not start an acquisition: a person imports the file into the acquisition software. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_worklist | 👁 read | Show a draft worklist in run order, with its defaults, blank/QC plan, randomisation seed and the history of operations applied to it. |
import_worklist | 👁 read | Parse an existing MassLynx, SCIEX OS, MassHunter or Xcalibur import file from the output folder into a draft, so it can be validated, edited or exported in another vendor's format. Columns without a neutral equivalent are kept verbatim. Only reads; nothing is written. |
insert_qc_blanks | 🎛 control | Insert blanks and QC injections and optionally randomise the run order (with a recorded seed). Replaces any previous plan, so calling it again does not duplicate blanks. The plan is re-applied whenever samples are added; data-file names follow the new run order. |
list_formats | 👁 read | List the supported import formats (Waters MassLynx, SCIEX OS, Agilent MassHunter, Thermo Xcalibur): columns, required fields, sample-type names, file extensions, how to import, what is verified against vendor documents and what is assumed, and the source URLs. Also lists the position patterns and the formats that were researched but not implemented. |
list_worklists | 👁 read | List the draft worklists in memory and the files in the output folder. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
validate_worklist | 👁 read | Check a draft against the target format: required fields, duplicate data-file names, characters Windows does not allow in file names, tray/vial position format and plate bounds, injection volume (> 0 and <= the max_injection_volume_ul limit), and method file extensions. Errors block export; warnings don't. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. There are no HAZARD tools: nothing here moves, heats, injects or acquires. The server only writes files. The CONTROL tools change in-memory drafts or write a file, and --read-only hides them.
Typical flow: create_worklist → add_samples (optional) → insert_qc_blanks → validate_worklist → export_worklist, then import the file in the vendor software.
The table below separates what the vendor documents say (verified) from what the server assumes. list_formats returns the same information to the agent. To be sure of the header for your software version, export an empty batch, sequence or worklist from your own system, put it in the output folder, and pass it to export_worklist as template_path. The server then writes that header, and that delimiter, exactly.
waters_masslynx)Index column is added. Source: WKB63781.FILE_NAME, INLET_FILE, MS_FILE, SAMPLE_LOCATION and INJ_VOL. Source: MassLynx 4.2 Getting Started Guide 715009602, Table 5-1. The "Bottle" column's FIELD ID is SAMPLE_LOCATION, not BOTTLE.TYPE values Blank/Standard/QC/Analyte, and method names without an extension.FILE_NAME = data file, FILE_TEXT = sample name, MS_FILE, MS_TUNE_FILE, INLET_FILE, SAMPLE_LOCATION, TYPE, ID, INJ_VOL, Index. You can add any other FIELD ID (for example CONC_A or QUAN_REF) per sample through extra.solvent and double_blank are written as Blank..exp for MS_FILE and .ipr for the tune file, applied only when an extension is given.waters_plate_well position pattern (1:A,1) is a common convention. Its comma is CSV-quoted.sciex_os).txt or .csv, and the column layout must come from a batch exported from SCIEX OS. Source: SCIEX KB.Sample Name,Sample ID,Sample Type,MS Method,LC Method,Rack Type,Rack Position,Plate Type,Plate Position,Vial Position,Injection Volume,Data File,Processing Method,Comment) is a best guess. Use template_path with your own export. validate_worklist and export_worklist warn when no template was used..msm, .lcm and .qmethod produce warnings only.vendor_columns or per sample with extra.agilent_masshunter)Sample Name,Barcode,Rack Code,Sample Position,Method,Data File,Sample Type,Level Name,Inj Vol (µL),Comment, positions like P1-A1, and the types Calibration and Sample come from the example file shipped in D:\MassHunter\Worklist_Import, as quoted on the Agilent Community.Inj Vol = -1 means "As method". Source: Agilent Known Problem Report..d suffix..m.solvent is written as Blank.thermo_xcalibur).csv files are accepted.Bracket Type=n (1 Overlapped, 2 None, 3 Non-Overlapped, 4 Open).冒頭だけを表示しています。続きはリポジトリで読めます