Spec Driven Development
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
제작자가 쓴 설명(영어 원문)
MCP server for Rigol oscilloscopes (DS1000Z, MSO5000, DHO series): measurements and waveforms.
이 세 가지는 절대 하나의 점수로 합치지 않아요. 의견, 측정, 인기는 서로 다른 것이니까요.
이 서버는 아직 쉬운 말로 된 요약을 쓰지 못했어요. 아래는 레지스트리에서 읽어 온 사실이에요.
쓰고 있는 AI 앱을 고른 다음 설정을 복사하세요.
LABMCP_ADDRESS, LABMCP_SIMULATE, LABMCP_READ_ONLY, LABMCP_LIMITS필요한 것
어떤 앱을 쓰세요?
위에서 앱을 고르세요. 기억해 두었다가 다음부터는 버튼에 “…에 설치”라고 표시해요.
Claude Desktop → Settings → Developer → Edit Config를 열고 claude_desktop_config.json에 이 내용을 붙여 넣으세요
{
"mcpServers": {
"labmcp-rigol-scope": {
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}터미널에서 이 명령어를 실행하세요
claude mcp add labmcp-rigol-scope --env LABMCP_ADDRESS=your-value --env LABMCP_SIMULATE=your-value --env LABMCP_READ_ONLY=your-value --env LABMCP_LIMITS=your-value -- uvx labmcp-rigol-scope실행하기 전에 빈 값을 채워 주세요.
프로젝트의 .cursor/mcp.json 또는 ~/.cursor/mcp.json에 붙여 넣으세요
{
"mcpServers": {
"labmcp-rigol-scope": {
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}브라우저가 앱을 열지 물어본 다음, 앱이 설정을 보여 주고 확인을 요청해요. 키 값은 비워 두니 직접 입력하세요.
프로젝트의 .vscode/mcp.json에 붙여 넣으세요
{
"servers": {
"labmcp-rigol-scope": {
"type": "stdio",
"command": "uvx",
"args": [
"labmcp-rigol-scope"
],
"env": {
"LABMCP_ADDRESS": "your-value",
"LABMCP_SIMULATE": "your-value",
"LABMCP_READ_ONLY": "your-value",
"LABMCP_LIMITS": "your-value"
}
}
}
}브라우저가 앱을 열지 물어본 다음, 앱이 설정을 보여 주고 확인을 요청해요. 키 값은 비워 두니 직접 입력하세요.
이 서버는 내 컴퓨터에서 실행되는데, ChatGPT는 인터넷에 있는 서버에만 연결할 수 있어요. 다른 앱을 고르세요.
선택한 앱은 이 기기의 쿠키에만 저장돼요. 계정은 필요 없어요.
LABMCP_ADDRESS envLABMCP_SIMULATE envLABMCP_READ_ONLY envLABMCP_LIMITS env이 설정은 제작자의 레지스트리 정보로 만들었어요. README와 다르면 README를 따르세요.
내 컴퓨터에서 실행돼요. 설치하면 AI 앱에 도구 목록이 나타나요.
누구나 볼 수 있는 정보를 점검했고, 코드는 읽지 않았어요. 해당하지 않는 항목은 개수에서 뺐어요. · 2026년 11월 7일 점검
레지스트리 이름이 GitHub 계정 K-Dense-AI 기준으로 확인되었고, 이 계정이 저장소를 소유하고 있어요
아직 GitHub에서 이 저장소를 읽어 오지 않았어요
아직 GitHub에서 이 저장소를 읽어 오지 않았어요
내 컴퓨터에서 실행되는 서버라 인터넷 엔드포인트가 없어요
내 컴퓨터에서 실행되며, 대신 로컬 설정을 사용해요
내 컴퓨터에서 실행돼요. 도구 목록은 인터넷 엔드포인트가 있는 서버에서만 읽을 수 있어요
레지스트리에서 이 카테고리의 활성 서버 전체와 비교했어요. 스타는 게시자가 저장소를 소유한 경우에만 세요.
해당하는 기본 점검 1개 중 1개를 통과했어요. 코드는 읽지 않았어요. 키나 토큰을 넣기 전에 서버가 어떤 권한을 요구하는지 확인하고, 꼭 필요한 권한만 있는 키를 쓰세요.
레지스트리에 필수 키가 나와 있지 않아요. 다만 처음 쓸 때 로그인을 요구하는 서버도 있어요.
내 컴퓨터에서 실행돼요. AI 앱이 필요할 때 실행하고, 데이터는 제작자의 서버를 거치지 않아요(서버 자체가 온라인 서비스를 호출하는 경우는 제외).
GitHub 저장소는 마지막으로 – 변경됐고, 최신 버전(0.1.2)은 42일 전 레지스트리에 올라왔어요.
Claude Desktop, Claude Code, Cursor, VS Code처럼 MCP를 지원하는 앱에서 쓸 수 있어요. 내 컴퓨터에 Python (uv)도 있어야 해요.
같은 카테고리에는: Spec Driven Development, Remote Desktop Commander, arr-mcp
같은 카테고리에서 다른 제작자가 만든 서버예요. 스타 순으로 정렬했어요.
카드 보는 법:★ GitHub 스타i세 기둥: 리뷰 · 점검 · 사용 정도i업데이트 = 최신 버전을 레지스트리에 공개한 날i
MCP Server that facilitates spec-driven development workflows, not just Vibe Coding.
Remote Desktop Commander: use files, terminal and processes on your own computers from any AI app.
One server, 40 tools, the whole media stack: *arrs, Jellyfin, Plex, Seerr, Cleanuparr, downloaders
제작자의 저장소에서 쓰인 그대로 가져왔어요. PopNx MCP가 검토하거나 보증한 내용이 아니에요. HTML, 이미지, 스크립트는 제거했어요. 링크를 누르면 이 사이트를 벗어나요.
Let an AI agent read the setup, adjust channels, timebase and trigger, run single acquisitions, take the scope's own measurements, capture calibrated waveforms and grab screenshots on Rigol digital oscilloscopes over SCPI.
| Package | labmcp-rigol-scope |
| Instruments | DS1000Z / MSO1000Z (DS1054Z, DS1074Z, DS1104Z, MSO1104Z, "Plus" models), DS1000Z-E (DS1102Z-E, DS1202Z-E), MSO5000 (MSO5072 … MSO5354), DHO800 / DHO900 (DHO802, DHO804, DHO914, DHO924), DHO1000 / DHO4000 (DHO1072 … DHO4804) |
| Interfaces | USB (USB-TMC), LAN (VXI-11/LXI, raw socket) |
| Protocol | SCPI per Rigol's programming guides: MSO1000Z/DS1000Z PGA19109-1110, DS1000Z-E PGA27100-1110, MSO5000 PGA25104-1110, DHO800/DHO900, DHO1000/DHO4000 PGA34101-1110 |
| Status | 🧪 simulated: tested against a wire-level SCPI simulator (including binary waveform and screenshot blocks), not yet verified on hardware. Report a hardware test |
uvx labmcp-rigol-scope --simulate --check
uvx labmcp-rigol-scope --simulate --option sim_model=DHO804 --check # also DS1202Z-E, MSO5074, DHO1204 ...
The simulated scope has a 1 kHz, 0-3 V square wave on CH1 and a 2 kHz, 1 V sine on CH2 (CH3/CH4 grounded). It answers :WAVeform:DATA? and :DISPlay:DATA? with real IEEE 488.2 binary blocks, keeps an SCPI error queue, and its trigger only fires when the level is inside the signal, so you can try single with a bad trigger level.
pyvisa-py backend, which needs libusb on the system (brew install libusb, apt install libusb-1.0-0; on Windows use NI-VISA with ?backend=@ivi). Find the resource with python -m pyvisa info or uvx labmcp ports. uvx labmcp-rigol-scope --address USB0::0x1AB1::0x04CE::DS1ZA123456789::INSTR --check # USB-TMC
uvx labmcp-rigol-scope --address TCPIP0::192.168.1.50::INSTR --check # LAN (VXI-11) uvx labmcp-rigol-scope --address tcp://192.168.1.50:5555 --check # LAN raw socket
`--check` prints the `*IDN?` identity and the detected command family.
Claude Code
claude mcp add scope -- uvx labmcp-rigol-scope --address TCPIP0::192.168.1.50::INSTR
Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)
{
"mcpServers": { "scope": { "command": "uvx", "args": ["labmcp-rigol-scope", "--address", "TCPIP0::192.168.1.50::INSTR"] } } }
Add --read-only to allow reading settings, measurements, waveforms and screenshots while blocking every tool that changes the scope setup. For other clients, generate the snippet with uvx labmcp config rigol-oscilloscope --address TCPIP0::192.168.1.50::INSTR --client vscode (also cursor, codex, claude-code).
| Tool | Kind | Description |
|---|---|---|
autoscale | 🎛 control | Run the scope's automatic setup (AUTO key): it picks vertical scales, timebase and trigger for the connected signals. This overwrites the user's current setup - only use it when asked. Needs signals of roughly >20 mVpp and >40 Hz. |
capture_waveform | 👁 read | Capture a channel's waveform, scaled to volts and seconds with the scope's waveform preamble, and return statistics plus a downsampled trace; optionally save all points to CSV. |
force_trigger | 🎛 control | Force one trigger (FORCE key). Only has an effect in NORMal or SINGle sweep while waiting. |
get_command_log | 👁 read | Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done. |
get_connection_info | 👁 read | Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first. |
get_device_info | 👁 read | Identify the oscilloscope (model, serial, firmware), the command family used for it, the number of analog channels, and the current sample rate and memory depth. |
get_settings | 👁 read | Read the current vertical settings of every channel (on/off, V/div, offset, coupling, probe ratio, bandwidth limit), the timebase, the trigger (type, sweep, status, edge source/level/slope) and the acquisition sample rate / memory depth. |
measure | 👁 read | Read the scope's automatic measurements for one channel: voltages (Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, overshoot, preshoot) and timing (period, frequency, rise/fall time, +/- width, +/- duty). Values the scope cannot determine are null. |
reconnect | 🛑 safety | Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged). |
run | 🎛 control | Start continuous acquisition (RUN). |
screenshot | 👁 read | Save a screenshot of the oscilloscope display (PNG; BMP on the MSO5000) and return its path. For PNG screenshots the image is also returned so the model can look at the screen. |
set_channel | 🎛 control | Change a channel's vertical settings; unspecified settings are left alone. The probe ratio is applied first because it changes the valid scale range. Returns the settings the scope actually applied (the scale snaps to 1-2-5 steps). Rejected values are reported from the scope's error queue. |
set_timebase | 🎛 control | Set the main timebase scale and/or offset. Returns the applied values. |
set_trigger | 🎛 control | Configure an edge trigger (source, level, slope) and the sweep mode. Sets the trigger type to EDGE. The level must lie within the source channel's screen range. |
single | 🎛 control | Arm a single acquisition (SINGLE key): the scope triggers once, then stops. With wait_s > 0 it waits until the acquisition is complete (status STOP). If the trigger condition is never met the status stays WAIT - check the trigger level/source or use force_trigger. |
stop | 🎛 control | Stop acquisition (STOP) and freeze the current waveforms, e.g. before reading deep memory. |
get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log shows every SCPI command sent.
| Limit | Default | Meaning |
|---|---|---|
max_memory_points | 1 200 000 points | Most points read from acquisition memory in one capture (bounds transfer time) |
Override at launch, e.g. --limit max_memory_points=24000000. An oscilloscope does not source energy, so there are no hazard tools; this server does not control the built-in waveform generator some models have.
:TRIGger:EDGE:LEVel, :MEASure:ITEM? VPP,CHANnel1, :WAVeform:PREamble?). The differences are taken from each guide: autoscale is :AUToscale (DS1000Z, MSO5000) or :AUToset (DHO); screenshots are :DISPlay:DATA? ON,OFF,PNG (DS1000Z), :DISPlay:DATA? PNG (DHO) or :DISPlay:DATA? → BMP (MSO5000); screen captures return 1200 points (DS1000Z, 12 divisions) or 1000 (MSO5000/DHO, 10 divisions). The family is detected from *IDN?; unknown Rigol models are refused unless you force --option profile=DS1000Z|MSO5000|DHO.:WAVeform:PREamble? and BYTE format: volts = (byte − YORigin − YREFerence) × YINCrement. WORD format is not used because the DHO guides do not document its byte order. For the 12-bit DHO scopes this means 8-bit screen/memory data.mode="memory") follows the documented RAW procedure: stop the scope, then read in batches of 250 000 points with :WAVeform:STARt/STOP (the DS1000Z maximum for BYTE). The MSO5000 and DHO guides document batched reads but not a maximum; the server checks every batch length and fails clearly if a batch comes back short. *Not yet verified on MSO5000/DHO hardware.*clipped_fraction counts points at the ADC limits (codes 0/255) in both modes. The returned trace keeps each block's minimum and maximum sample, so narrow glitches survive downsampling. save_path (CSV) and the screenshot save_path (.png, .bmp on the MSO5000) must be new files: they are checked before anything is read, and existing files are never overwritten.null when the scope answers 9.9E37 (cannot measure). Duty cycle and overshoot are reported exactly as the scope returns them (the DS1000Z guide defines duty as a ratio).:SYSTem:ERRor? afterwards, so an out-of-range scale, offset or trigger level is reported instead of silently ignored. The scale snaps to 1-2-5 steps unless fine adjustment (VERNier) is on.TCPIP0:: ::INSTR). Rigol scopes also accept raw SCPI on TCP port 5555 (tcp:// :5555); that port is widely used but not stated in these guides.libusb for pyvisa-py; pyusb is installed with this package.| Model | Firmware | Interface | Verified by | Date |
|---|---|---|---|---|
| *none yet: be the first* |